Inspections for the day of: Tuesday, December 24, 2019.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05405 Final12/18/201912/24/201912/24/2019 10:37:15 AMAPASS
Tenant is Dave ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC19-04530 Rough-in12/23/201912/24/201912/24/2019 10:10:30 AMAPART
Partial cover, please call Ted at least 30 min prior to inspection, thank you and Merry Christmas. Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- three dampers added on north side clearances ok for angles
- duct seal on 18" supply in hallway between two dampers ok for insulation
- main duct still needs ran out to RTU
-Partial cover ok leave tiles out where HVAC work needs to be seen for inspection
MEC19-04687 Final12/23/201912/24/201912/24/2019 9:35:07 AMAFAIL
Request final inspection of 75k heater for detached shop. pressure test inspection complete on line to shop, 2nd inspection done line to unit. Gas line is now to the unit and its operating. Electrical inspection passed and complete. Available after 10AM please. ###-#### Phone #: ###-#### Inspection requested via web by ron powell
- need to installed insulation shield through wall to maintain 1" clearances to combustibles
MEC19-01679 Rough-in12/23/201912/24/201912/24/2019 8:58:41 AMAPASS
Grease duct Phone #: ###-#### Inspection requested via web by Amanda Farnsworth
- light test on field weld at drop to 90 and square/round ok marked prints
- small amount of duct seal in corridor ok for insulation marked prints
MEC19-04647 Final12/23/201912/24/201912/24/2019 8:08:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Matthew BLANKENSHIP
- final ok
MEC19-02406 Mec-Aging Inspection12/24/201912/24/201912/24/2019 8:07:28 AM FAIL
Permit has not been active since being issued on 6-10-19. Schedule inspection with homeowner if work is finished. Permit will expired at next mechanical aging inspection if not active.
MEC19-02397 Mec-Aging Inspection12/24/201912/24/201912/24/2019 8:06:09 AM PASS
Doc Permit Finaled ok
MEC19-02397 DOC - Permit Finaled12/24/201912/24/201912/24/2019 8:05:36 AMAPASS
Doc Permit Finaled ok
MEC19-02412 Mec-Aging Inspection12/24/201912/24/201912/24/2019 8:04:53 AM PASS
WIP
MEC19-00717 Mec-Aging Inspection12/24/201912/24/201912/24/2019 8:04:25 AM PASS
Doc Permit Finaled ok
MEC19-00717 DOC - Permit Expired12/24/201912/24/201912/24/2019 8:04:09 AMAPASS
Doc Permit Finaled
MEC19-02400 Mec-Aging Inspection12/24/201912/24/201912/24/2019 8:00:30 AM PASS
Doc Permit Finaled
MEC19-02400 DOC - Permit Finaled12/24/201912/24/201912/24/2019 8:00:15 AMAPASS
Doc Permit Finaled ok