MEC19-05528
| Pressure Test | 12/6/2019 | 12/6/2019 | 12/6/2019 3:56:02 PM | P | FAIL |
|
|
gage on east sie of house,call if lock box is needed, gas line is visable in crawl outsideback yard access Phone #: ###-#### Inspection requested via web by brett hoopes -gas piping outside needs to be 3.5" above ground. Where gas line enters basment gas line also needs to be 3.5" above ground - gas line penetration needs 10mill tape installed and penetration sealed -gas line needs supported in basement and outside of house
|
MEC19-05457
| Rough-in | 12/5/2019 | 12/6/2019 | 12/6/2019 3:37:27 PM | P | PASS |
|
|
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace R/I ok
|
MEC19-05350
| Final | 12/6/2019 | 12/6/2019 | 12/6/2019 3:31:51 PM | P | CANC |
|
|
Lockbox code is 1606. Phone #: ###-#### Inspection requested via web by Loren Bailey - talked with HVAC contractor about access to home. Will need to someone to walk me through house
|
MEC19-05152
| Final | 12/5/2019 | 12/6/2019 | 12/6/2019 3:10:14 PM | P | NH |
|
|
Santiago Phone #: ###-#### - called number in notes - no access to house
|
MEC19-04828
| Rough-in | 12/6/2019 | 12/6/2019 | 12/6/2019 2:33:26 PM | P | FAIL |
|
|
-range vent seal ok - flue needs 1" clearances through roof - when draft stop is in place at attic need to see clearances/ insulation shield
|
MEC19-05509
| Pressure Test | 12/6/2019 | 12/6/2019 | 12/6/2019 2:18:06 PM | P | FAIL |
|
|
Corrected issue at valve. Under test again. Ready for reinspection. Phone #: ###-#### Inspection requested via web by Scott Sparrell - need 10mil tape installed at penetration - 20lb gas pressure test ok will tag meter when tape is installed
|
MEC19-05259
| Final | 12/2/2019 | 12/6/2019 | 12/6/2019 1:47:15 PM | P | NH |
|
|
Please have inspector call Dan when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd - Talked with homeowner Dan about inspection this afternoon. Dan stated he wouldnt be home by the time I was in the area. I reschedule inspection for homeowner next week on 12-11-19 for the afternoon
|
MEC19-05519
| Final | 12/6/2019 | 12/6/2019 | 12/6/2019 1:31:32 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - furnace flue needs to enter common vent wye at the lowest point. switch water heater and furnace flue at wye - common vent wye needs to be double wall b vent
|
MEC19-05219
| Final | 12/5/2019 | 12/6/2019 | 12/6/2019 1:10:42 PM | P | PASS |
|
|
WE ARE DOING CORRECTIONS EARLY AFTERNOON FOR THIS JACK- IF YOU CAN MOVE THIS CLOSER TO END OF DAY WE WILL HAVE EVERYTHING CORRECTED AND DONE. PLEASE CALL KATIE WHEN YOUR IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery - final ok
|
MEC19-05228
| Final | 12/3/2019 | 12/6/2019 | 12/6/2019 12:00:22 PM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 11:30 AM. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette - 5lb flue pressure test ok - final ok
|
MEC19-05440
| Final | 12/4/2019 | 12/6/2019 | 12/6/2019 11:28:50 AM | A | PASS |
|
|
Please call property mgr, Catie about 30 minutes prior to inspection so she can meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC19-05517
| Final | 12/5/2019 | 12/6/2019 | 12/6/2019 11:16:59 AM | A | PASS |
|
|
please call our lead installer Jonah when 30-45 mins in route so he can get onsite and have flue under pressure when you arrive Phone #: ###-#### Inspection requested via web by Rick Montgomery - 5lb flue pressure test ok - furnace only co ok
|
MEC19-05419
| Final | 12/4/2019 | 12/6/2019 | 12/6/2019 10:48:53 AM | A | PASS |
|
|
please call Cole 1/2 hr out. thank you!!! Phone #: ###-#### Inspection requested via web by Denise Colin - furnace only co ok
|
MEC19-05121
| Rough-in | 12/5/2019 | 12/6/2019 | 12/6/2019 10:22:18 AM | A | FAIL |
|
|
House is completely empty. The code at the front door is 8090. Phone #: ###-#### Inspection requested via web by Nicolas Barajas - 20lb gas pressure test fail
|
MEC19-05121
| Pressure Test | 12/5/2019 | 12/6/2019 | 12/6/2019 10:21:59 AM | A | FAIL |
|
|
House is completely empty. The code at the front door is 8090. Gas line to range and furnace Phone #: ###-#### Inspection requested via web by Nicolas Barajas - 20lb gas pressure test fail gauge was under 20lb
|
MEC19-05479
| Final | 12/6/2019 | 12/6/2019 | 12/6/2019 9:34:08 AM | A | CANC |
|
|
call Dustin & he will bring you a ladder ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|
MEC19-05106
| Rough-in | 12/5/2019 | 12/6/2019 | 12/6/2019 9:32:50 AM | P | CANC |
|
|
Michael ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
|
MEC19-05492
| Final | 12/5/2019 | 12/6/2019 | 12/6/2019 9:31:31 AM | A | PASS |
|
|
Please call homeowner Tom when on way ###-#### Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - furnace only co ok
|
MEC19-05155
| Final | 12/2/2019 | 12/6/2019 | 12/6/2019 9:17:18 AM | A | FAIL |
|
|
Please call Jack in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout - furnace needs a disconnect installed
|
MEC19-05509
| Pressure Test | 12/5/2019 | 12/6/2019 | 12/6/2019 9:04:43 AM | A | FAIL |
|
|
Sean is journeyman that completed install if questions. Thanks. Phone #: ###-#### Inspection requested via web by Scott Sparrell - gauge was flat
|
MEC19-04828
| Rough-in | 12/5/2019 | 12/6/2019 | 12/6/2019 8:52:42 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Michael Stimpson - need access to see new flue pipe in attic - range vent needs sealed
|
MEC18-05201
| Mec-Aging Inspection | 12/6/2019 | 12/6/2019 | 12/6/2019 8:03:18 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC18-05201
| DOC - Permit Expired | 12/6/2019 | 12/6/2019 | 12/6/2019 8:03:00 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC19-04004
| Final | 12/5/2019 | 12/6/2019 | 12/5/2019 12:36:34 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|
MEC19-04003
| Final | 12/5/2019 | 12/6/2019 | 12/5/2019 12:36:02 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
|