Inspections for the day of: Friday, December 6, 2019.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-05528 Pressure Test12/6/201912/6/201912/6/2019 3:56:02 PMPFAIL
gage on east sie of house,call if lock box is needed, gas line is visable in crawl outsideback yard access Phone #: ###-#### Inspection requested via web by brett hoopes
-gas piping outside needs to be 3.5" above ground. Where gas line enters basment gas line also needs to be 3.5" above ground
- gas line penetration needs 10mill tape installed and penetration sealed
-gas line needs supported in basement and outside of house
MEC19-05457 Rough-in12/5/201912/6/201912/6/2019 3:37:27 PMPPASS
Mechanical Gas Fireplace Rough-In Inspection Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace R/I ok
MEC19-05350 Final12/6/201912/6/201912/6/2019 3:31:51 PMPCANC
Lockbox code is 1606. Phone #: ###-#### Inspection requested via web by Loren Bailey
- talked with HVAC contractor about access to home. Will need to someone to walk me through house
MEC19-05152 Final12/5/201912/6/201912/6/2019 3:10:14 PMPNH
Santiago Phone #: ###-####
- called number in notes
- no access to house
MEC19-04828 Rough-in12/6/201912/6/201912/6/2019 2:33:26 PMPFAIL
-range vent seal ok
- flue needs 1" clearances through roof
- when draft stop is in place at attic need to see clearances/ insulation shield
MEC19-05509 Pressure Test12/6/201912/6/201912/6/2019 2:18:06 PMPFAIL
Corrected issue at valve. Under test again. Ready for reinspection. Phone #: ###-#### Inspection requested via web by Scott Sparrell
- need 10mil tape installed at penetration
- 20lb gas pressure test ok
will tag meter when tape is installed
MEC19-05259 Final12/2/201912/6/201912/6/2019 1:47:15 PMPNH
Please have inspector call Dan when in route to home ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- Talked with homeowner Dan about inspection this afternoon. Dan stated he wouldnt be home by the time I was in the area. I reschedule inspection for homeowner next week on 12-11-19 for the afternoon
MEC19-05519 Final12/6/201912/6/201912/6/2019 1:31:32 PMPFAIL
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
- furnace flue needs to enter common vent wye at the lowest point. switch water heater and furnace flue at wye
- common vent wye needs to be double wall b vent
MEC19-05219 Final12/5/201912/6/201912/6/2019 1:10:42 PMPPASS
WE ARE DOING CORRECTIONS EARLY AFTERNOON FOR THIS JACK- IF YOU CAN MOVE THIS CLOSER TO END OF DAY WE WILL HAVE EVERYTHING CORRECTED AND DONE. PLEASE CALL KATIE WHEN YOUR IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery
- final ok
MEC19-05228 Final12/3/201912/6/201912/6/2019 12:00:22 PMAPASS
This is a Flue Pressure and Final Inspect. Please meet our installer
at home at 11:30 AM. Contact for Right Now is Mary ###-####

Phone #: ###-#### Inspection requested via web by Mary LaFayette
- 5lb flue pressure test ok
- final ok
MEC19-05440 Final12/4/201912/6/201912/6/2019 11:28:50 AMAPASS
Please call property mgr, Catie about 30 minutes prior to inspection so she can meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC19-05517 Final12/5/201912/6/201912/6/2019 11:16:59 AMAPASS
please call our lead installer Jonah when 30-45 mins in route so he can get onsite and have flue under pressure when you arrive Phone #: ###-#### Inspection requested via web by Rick Montgomery
- 5lb flue pressure test ok
- furnace only co ok
MEC19-05419 Final12/4/201912/6/201912/6/2019 10:48:53 AMAPASS
please call Cole 1/2 hr out. thank you!!! Phone #: ###-#### Inspection requested via web by Denise Colin
- furnace only co ok
MEC19-05121 Rough-in12/5/201912/6/201912/6/2019 10:22:18 AMAFAIL
House is completely empty. The code at the front door is 8090. Phone #: ###-#### Inspection requested via web by Nicolas Barajas
- 20lb gas pressure test fail
MEC19-05121 Pressure Test12/5/201912/6/201912/6/2019 10:21:59 AMAFAIL
House is completely empty. The code at the front door is 8090.
Gas line to range and furnace Phone #: ###-#### Inspection requested via web by Nicolas Barajas
- 20lb gas pressure test fail gauge was under 20lb
MEC19-05479 Final12/6/201912/6/201912/6/2019 9:34:08 AMACANC
call Dustin & he will bring you a ladder ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
MEC19-05106 Rough-in12/5/201912/6/201912/6/2019 9:32:50 AMPCANC
Michael ###-#### Phone #: ###-#### >> Inspection requested via web by Mike Almanza Inspection cancelled from web by: Mike Almanza
MEC19-05492 Final12/5/201912/6/201912/6/2019 9:31:31 AMAPASS
Please call homeowner Tom when on way ###-#### Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek
- furnace only co ok
MEC19-05155 Final12/2/201912/6/201912/6/2019 9:17:18 AMAFAIL
Please call Jack in route to inspection ###-#### Phone #: ###-#### Inspection requested via web by Justin Osterhout
- furnace needs a disconnect installed
MEC19-05509 Pressure Test12/5/201912/6/201912/6/2019 9:04:43 AMAFAIL
Sean is journeyman that completed install if questions. Thanks. Phone #: ###-#### Inspection requested via web by Scott Sparrell
- gauge was flat
MEC19-04828 Rough-in12/5/201912/6/201912/6/2019 8:52:42 AMAFAIL
Phone #: ###-#### Inspection requested via web by Michael Stimpson
- need access to see new flue pipe in attic
- range vent needs sealed
MEC18-05201 Mec-Aging Inspection12/6/201912/6/201912/6/2019 8:03:18 AM PASS
Doc Permit Expired ok
MEC18-05201 DOC - Permit Expired12/6/201912/6/201912/6/2019 8:03:00 AMAPASS
Doc Permit Expired ok permit not active
MEC19-04004 Final12/5/201912/6/201912/5/2019 12:36:34 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart
MEC19-04003 Final12/5/201912/6/201912/5/2019 12:36:02 PMPCANC
Phone #: ###-#### >> Inspection requested via web by Randy Hart Inspection cancelled from web by: Randy Hart