Inspections for the day of: Wednesday, February 12, 2020.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-00586 Final2/10/20202/12/20202/12/2020 4:10:41 PMPPASS
Same day install. Please contact technician on site to be sure project is ready for inspection. Technician on site Tony Hall ###-####. Thanks Phone #: ###-#### Inspection requested via web by Kelly Martin
- furnace ac coil co ok
MEC20-00382 Rough-in2/12/20202/12/20202/12/2020 3:45:44 PMPFAIL
Call before you go so we can ensure someone is there Phone #: ###-#### Inspection requested via web by Dan McFate
- need to seal floor boots to floor
-fresh air needs installed
- line set needs installed
toe kick supplies need ducted out
- add fireplace and range to permit
MEC19-05551 Final2/12/20202/12/20202/12/2020 3:44:41 PMPNH
Lock box under panel in back of building Phone #: ###-#### Inspection requested via web by Cesar Rodriguez
- no access couldnt find key at back of building
MEC19-04898 Final2/12/20202/12/20202/12/2020 3:09:50 PMPFAIL
Thank you Phone #: ###-#### Inspection requested via web by Aaron Johns
- 2428.2.9 IRC 2012 any b vent exposed more than 5' to the outdoors shall be enclosed or chased and insulated to not less than R-8
/ vent manufactures specs for being in an enclosure- need to add range and fireplace to permit
- need air balance report
- electrical needs finished at furnace and A/C
- b vent needs 1" clearances
- line set needs UV protection and locking installed on A/C
- all penetrations need sealed
- water heater needs sediment trap in gas line
MEC20-00599 Final2/12/20202/12/20202/12/2020 1:58:40 PMPPASS
Final Mechanical ; Flue Test - Installer Aaron requested late afternoon as possible. Aaron ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd
- furnace ac coil co ok
MEC20-00611 Final2/11/20202/12/20202/12/2020 1:47:42 PMPPASS
Please call Willie prior to arrival to ensure ready for inspection. Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- furnace ac coil co ok
MEC20-00577 Final2/11/20202/12/20202/12/2020 1:12:30 PMPPASS
Please Inspect later PM and call Dave on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- furnace only co ok
MEC20-00387 Rough-in2/11/20202/12/20202/12/2020 11:30:17 AMAPASS
Call when you are on the way so we can be sure someone is there Phone #: ###-#### Inspection requested via web by Dan McFate
- gas line installation hasn't been started yet. schedule pressure test when ready
- permit needs to be adjusted to match work being done
- UL listed connector for plastic coated MC cable installed by final
MEC20-00059 Rough-in2/11/20202/12/20202/12/2020 11:06:38 AMAFAIL
if questions call Nolan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
- gas gauge should be 30lb gauge at 20 lb
change out gauges and reschedule
MEC20-00444 Rough-in2/11/20202/12/20202/12/2020 11:05:42 AMAPART
Phone #: ###-#### Inspection requested via web by Dave Sorensen
- partial R/I ok
- duct seal ok for insulation
MEC20-00586 Pressure Test2/10/20202/12/20202/12/2020 10:32:51 AMACANC
Please contact technician on site with an ETA to be sure is ready for Pressure Test. Technician on site Tony Hall ###-####. Thanks Phone #: ###-#### Inspection requested via web by Kelly Martin
- no need for 5lb flue witness
MEC18-05404 Final2/11/20202/12/20202/12/2020 10:16:06 AMAPASS
code is 2592. Man J should be near furnace. Phone #: ###-#### Inspection requested via web by Angie Thome
- final ok
MEC18-05267 DOC - Permit Finaled2/12/20202/12/20202/12/2020 10:15:46 AMPPASS
fireplace final ok
MEC19-03327 Mec-Aging Inspection2/12/20202/12/20202/12/2020 8:10:48 AM FAIL
Permit has not been active since being issued on 7-30-19. Schedule inspection with owner if work is finished. Permit will expire at next mechanical aging inspection if not active.
MEC19-01739 Mec-Aging Inspection2/12/20202/12/20202/12/2020 7:59:35 AM PASS
Doc Permit Expired ok
MEC19-01739 DOC - Permit Expired2/12/20202/12/20202/12/2020 7:58:05 AMAPASS
Doc Permit Expired ok permit not active
MEC19-05773 Final2/11/20202/12/20202/11/2020 11:50:37 AMACANC
Please call Val when on way: ###-#### Phone #: ###-#### >> Inspection requested via web by Arielle Hendricks Inspection cancelled from web by: Arielle Hendricks