MEC18-03087
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 4:43:50 PM | P | PASS |
|
|
Thomas Phone #: ###-#### - final ok
|
MEC18-05559
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 3:54:39 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bruce Lacy - final ok
|
MEC18-05005
| Rough-in | 2/7/2019 | 2/7/2019 | 2/7/2019 3:20:40 PM | P | PASS |
|
|
Trim smoke fire dampers 3rd ; 4th floor bathrooms - call Daryl ###-#### Phone #: ###-#### Inspection requested via web by Heather Gransbery - 3rd and 4th floor smoke fire damper trim ok - bathrooms on 3rd and 4th floor ceiling cover ok
|
MEC19-00536
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 2:56:52 PM | P | PASS |
|
|
Please call Tyrel prior to arrival ###-#### Inspection requested via web by Arielle Hendricks - furnace ac coil co ok
|
MEC19-00539
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 2:30:09 PM | P | PASS |
|
|
Early pm please. Call Dan prior to arrival ###-#### Inspection requested via web by Arielle Hendricks - unit heater final ok
|
MEC19-00508
| Rough-in | 2/6/2019 | 2/7/2019 | 2/7/2019 2:17:07 PM | P | FAIL |
|
|
Please call Bill on your way out. ###-#### Phone #: ###-#### Inspection requested via web by Vance Poulsen - flec ducting needs to be installed per manufactures spec (zip tie outer liner) - north flex duct needs to be replaced with outer liner installed - one supply duct needs insulation installed - b vent needs 1" clearances to dry wall - return duct needs to be installed in new location if being moved from current location - bathroom exhaust needs to be finished - return duct in attic is being smashed by trusses and needs fixed - furnace and water heater flue needs 3 screws
|
MEC18-05953
| Rough-in | 2/7/2019 | 2/7/2019 | 2/7/2019 1:20:43 PM | P | PART |
|
|
PART NORTH SIDE Phone #: ###-#### Inspection requested via web by Oleg Chervak - R/I of north side 12 units ok BLD B
|
MEC19-00487
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 1:19:37 PM | P | PASS |
|
|
Electrical permit pulled and inspection scheduled. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - furnace only co ok - electrical permit was pulled
|
MEC18-05700
| Final | 2/5/2019 | 2/7/2019 | 2/7/2019 12:18:10 PM | A | PASS |
|
|
Access: 9378 Jarrod: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello - final ok
|
MEC19-00274
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 11:07:50 AM | A | PASS |
|
|
Field super: Chad Robertson Tenant: Gary requesting a time of 930am please call him when on your way at ###-#### thank-you. Phone #: ###-#### Inspection requested via web by Lisa Whitney -furnace only co ok
|
MEC18-04629
| Final | 2/1/2019 | 2/7/2019 | 2/7/2019 10:45:05 AM | A | PASS |
|
|
Please call client prior to arrival at ###-#### Thank you Phone #: ###-#### Inspection requested via web by Andrea Grigsby - furnace ac coil co ok
|
MEC18-05005
| Rough-in | 2/6/2019 | 2/7/2019 | 2/7/2019 10:11:35 AM | A | PART |
|
|
Cover for 3rd and 4th floor bathrooms Phone #: ###-#### Inspection requested via web by Heather Gransbery - need to see trim around fire dampers on 3rd and 4th floor before cover of bathrooms
|
MEC18-04940
| DOC - Permit Finaled | 2/7/2019 | 2/7/2019 | 2/7/2019 9:23:39 AM | P | PASS |
|
|
final ok
|
MEC19-00544
| DOC - Permit Finaled | 2/7/2019 | 2/7/2019 | 2/7/2019 9:22:49 AM | P | PASS |
|
|
|
MEC19-00544
| Rough-in | 2/6/2019 | 2/7/2019 | 2/7/2019 9:22:23 AM | A | PASS |
|
|
please call Chris 1st when on way ###-#### ###-#### Inspection requested via web by Terek Worley - 20lb gas pressure test ok - dryer vent ok
|
MEC19-00483
| Final | 2/6/2019 | 2/7/2019 | 2/7/2019 8:59:04 AM | A | FAIL |
|
|
Inspection requested via web by Margie Rowe - line set penetration needs to be sealed - need to also see an electrical permit pulled for new heat pump being installed - furnace and coil ok
|
MEC18-01762
| Mec-Aging Inspection | 2/7/2019 | 2/7/2019 | 2/7/2019 8:02:00 AM | | FAIL |
|
|
need to schedule inspection of A/C installation
|