MEC19-02542
| Final | 6/25/2019 | 6/28/2019 | 6/28/2019 4:10:44 PM | P | NH |
|
|
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg - no access left notice on front door
|
MEC19-01677
| Rough-in | 6/28/2019 | 6/28/2019 | 6/28/2019 3:39:20 PM | P | FAIL |
|
|
field super; Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - need stamped man J onsite
|
MEC19-01677
| Pressure Test | 6/28/2019 | 6/28/2019 | 6/28/2019 3:38:52 PM | P | PASS |
|
|
field super; Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - 20lb gas pressure test ok - tagged meter location
|
MEC19-02797
| Pressure Test | 6/28/2019 | 6/28/2019 | 6/28/2019 3:13:49 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK - high pressure test needs to be 100lb gauge at 60lb
|
MEC19-00240
| Pressure Test | 6/28/2019 | 6/28/2019 | 6/28/2019 2:55:49 PM | P | PASS |
|
|
Contact: ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy - Area B 3rd floor southside 3 units only 20lb gas pressure test ok
|
MEC19-02325
| Final | 6/27/2019 | 6/28/2019 | 6/28/2019 2:01:03 PM | P | PASS |
|
|
range final inspection homeowner, tina will be home all day. Phone #: ###-#### Inspection requested via web by Rick Jones
|
MEC19-02325
| Final | 6/27/2019 | 6/28/2019 | 6/28/2019 2:00:55 PM | P | PASS |
|
|
range final inspection homeowner, tina will be home all day. Phone #: ###-#### Inspection requested via web by Rick Jones
|
MEC19-02783
| Final | 6/28/2019 | 6/28/2019 | 6/28/2019 1:44:45 PM | P | PASS |
|
|
please call homeowner to give her a heads up if possible Sandy Roberts ###-#### Phone #: ###-#### Inspection requested via web by Nick Drake
|
MEC19-02710
| Final | 6/24/2019 | 6/28/2019 | 6/28/2019 1:36:20 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC19-02608
| Final | 6/27/2019 | 6/28/2019 | 6/28/2019 11:45:53 AM | A | NH |
|
|
Sent photos of corrections to Jack''s cel phone Phone #: ###-#### Inspection requested via web by John Bertram - No access to home
|
MEC19-02759
| Final | 6/26/2019 | 6/28/2019 | 6/28/2019 11:16:55 AM | A | FAIL |
|
|
PLEASE CALL HOMEOWNER JOYCE WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery - duct insulation needs to be installed per manu. installation instructions - furnace ac coil co ok
|
MEC19-02516
| Rough-in | 6/27/2019 | 6/28/2019 | 6/28/2019 10:46:11 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Melissa Skinner - several locations are missing ducted return air - need to seal all common exhaust duct work up to roof line
|
MEC19-02796
| Rough-in | 6/27/2019 | 6/28/2019 | 6/28/2019 10:03:14 AM | A | FAIL |
|
|
Fernando Phone #: ###-#### - Man J needs approved by the City of Boise - duct work needs to match the Man J - gas line needs to be extended to mec room - one exhaust fan needs connected - supply boots need sealed - one branch line needs sealed under stairs - need to see fresh air installed on system - line set needs installed for R/I
|
MEC19-02272
| Pressure Test | 6/26/2019 | 6/28/2019 | 6/28/2019 9:24:50 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nicholas Paige 2- 100lb gas pressure tests for building shell ok 1- 100lb gas pressure test for unit 110 ok - tagged meter location
|
MEC19-02797
| Pressure Test | 6/27/2019 | 6/28/2019 | 6/28/2019 9:11:28 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by PATTY KIRK Inspection cancelled from web by: PATTY KIRK
|
MEC19-02609
| Final | 6/26/2019 | 6/28/2019 | 6/28/2019 9:06:19 AM | A | FAIL |
|
|
Please call Carrie on your way at ###-####. Thanks! Phone #: ###-#### Inspection requested via web by Misty Merry - a new impact barrier needs to be installed in front of tankless water heater and furnace - furnace ac coil co ok
|
MEC19-02601
| Rough-in | 6/27/2019 | 6/28/2019 | 6/28/2019 8:49:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans - R/I ok
|
MEC18-02743
| Mec-Aging Inspection | 6/28/2019 | 6/28/2019 | 6/28/2019 8:23:21 AM | | FAIL |
|
|
This permit still has no activities after failing a R/I inspection. Schedule an inspection if corrections have been made. Permit will expire at the next mechanical aging inspection if not active.
|
MEC18-05611
| Mec-Aging Inspection | 6/28/2019 | 6/28/2019 | 6/28/2019 8:02:44 AM | | FAIL |
|
|
This permit has not been active since not being ready for an inspection on 11/20/2018. If work is finished schedule inspection with the homeowner. Permit will expire at next mechanical aging inspection and have to be re issued with fees paid
|
MEC19-02499
| Rough-in | 6/26/2019 | 6/28/2019 | 6/26/2019 12:22:02 PM | A | CANC |
|
|
Please call ahead to Curtis ###-####. Rough-in for exhaust fan only. Phone #: ###-#### >> Inspection requested via web by Whitney Newsom Inspection cancelled from web by: Whitney Newsom
|