MEC18-03226
| Final | 7/8/2018 | 7/13/2018 | 7/13/2018 3:29:36 PM | P | PASS |
|
|
Please call on way so I can make sure someone is there to let you in, you can call my cell at ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon- 20lb gas pressure test ok
|
MEC18-03327
| Pressure Test | 7/12/2018 | 7/13/2018 | 7/13/2018 2:54:29 PM | P | PASS |
|
|
Flue test and Final please, please call Installer to see about flue test at ###-#### and with any questions. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- 5lb flue pressure test ok
|
MEC18-03327
| Final | 7/13/2018 | 7/13/2018 | 7/13/2018 2:53:50 PM | P | PASS |
|
|
Flue test and Final please, please call Installer to see about flue test at ###-#### and with any questions. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- furnace ac coil co ok
|
MEC18-03169
| Final | 7/13/2018 | 7/13/2018 | 7/13/2018 2:46:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace ac coil co ok
|
MEC18-03169
| Pressure Test | 7/13/2018 | 7/13/2018 | 7/13/2018 2:17:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Justin Osterhout- 5lb flue pressure test ok- 20lb gas pressure test ok
|
MEC18-03311
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 1:45:32 PM | P | NR |
|
|
Please call on way: Joseph ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
|
MEC18-03311
| Pressure Test | 7/13/2018 | 7/13/2018 | 7/13/2018 1:45:23 PM | P | PASS |
|
|
Please call on way: Joseph ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 5lb flue pressure test ok
|
MEC18-03273
| Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 12:52:25 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- supply run upstairs in loft is kinked/ smashed- supply run into laundry is kinked- supply run into west upstairs bedroom kinked by truss- return into master is kinked-return into east upstairs bedroom kinked- need to seal end cap on ducting at furnace
|
MEC18-03273
| Pressure Test | 7/12/2018 | 7/13/2018 | 7/13/2018 12:42:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pressure test ok
|
MEC18-01723
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 11:44:24 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok- need RM permit to be finaled before full final
|
MEC17-05257
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 11:43:51 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok need RM mechanical permit to be finaled before full final
|
MEC18-03050
| Rough-in | 7/12/2018 | 7/13/2018 | 7/13/2018 11:42:45 AM | P | PART |
|
|
Contact Name: Aaron Roberts Duct rough-in Phone #: ###-#### Inspection requested via web by RM Mechanical- duct work ok for insulation
|
MEC18-03267
| Pressure Test | 7/10/2018 | 7/13/2018 | 7/13/2018 11:15:21 AM | A | FAIL |
|
|
Please call Breaganat ###-#### - to coordinate. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- 5lb flue pressure test fail gauge was at zero- A/C fuse size to large- need drip leg in gas line at furnace- need co detectors installed- need to see combustion air ran to furnace-
|
MEC18-02433
| Final | 7/6/2018 | 7/13/2018 | 7/13/2018 10:29:11 AM | A | FAIL |
|
|
Please call when in route to home at ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- lineset insulation in basment needs to be tape where old lineset and new meet- secondary drain needs a wet switch cant not drain into primary and pump
|
MEC18-03268
| Final | 7/11/2018 | 7/13/2018 | 7/13/2018 10:08:43 AM | A | FAIL |
|
|
homeowner # ###-#### - michael thank you! Phone #: ###-#### Inspection requested via web by Aaron Alandt- need to place another combustion air vent in door( front of furnace)- lineset has a rip in the insulation above the water heater- above the water heater has building insulation touching the common vent(flue) need 1" clearances- lineset is also within 1" of the furnace flue near the water heater- A/C breaker size is too large needs to be a 25amp
|
MEC18-03303
| Final | 7/11/2018 | 7/13/2018 | 7/13/2018 9:48:19 AM | A | FAIL |
|
|
Please call home owner Dr Byrd or Jessica at ###-#### when in route to home. Phone #: ###-#### Inspection requested via web by Carolyn Rudd- need to see co detectors in house - call back in inspection when co are installed
|
MIS18-00257
| MEC-Conference | 7/11/2018 | 7/13/2018 | 7/13/2018 9:27:32 AM | A | DONE |
|
|
|
MEC17-03505
| Mec-Aging Inspection | 7/13/2018 | 7/13/2018 | 7/13/2018 8:22:06 AM | | DONE |
|
|
called A-1 to schedule inspection with homeowner
|
MEC18-03218
| Final | 7/12/2018 | 7/13/2018 | 7/13/2018 7:56:50 AM | A | PASS |
|
|
Please call Dan at ###-#### with a 30 minute heads up arrival time. Phone #: ###-#### Inspection requested via web by David or K Cole- lineset penetration sealed ok- ac coil co ok
|
MEC17-04742
| DOC - Permit Finaled | 7/13/2018 | 7/13/2018 | 7/13/2018 7:54:58 AM | P | PASS |
|
|
final ok
|
MEC17-04742
| Mec-Aging Inspection | 7/13/2018 | 7/13/2018 | 7/13/2018 7:54:08 AM | | DONE |
|
|
|
MEC18-03273
| Pressure Test | 7/12/2018 | 7/13/2018 | 7/12/2018 2:37:07 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|
MEC18-03273
| Rough-in | 7/12/2018 | 7/13/2018 | 7/12/2018 2:37:06 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
|