Inspections for the day of: Friday, July 13, 2018.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03226 Final7/8/20187/13/20187/13/2018 3:29:36 PMPPASS
Please call on way so I can make sure someone is there to let you in, you can call my cell at ###-#### Phone #: ###-#### Inspection requested via web by Brett Shannon- 20lb gas pressure test ok
MEC18-03327 Pressure Test7/12/20187/13/20187/13/2018 2:54:29 PMPPASS
Flue test and Final please, please call Installer to see about flue test at ###-#### and with any questions. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- 5lb flue pressure test ok
MEC18-03327 Final7/13/20187/13/20187/13/2018 2:53:50 PMPPASS
Flue test and Final please, please call Installer to see about flue test at ###-#### and with any questions. Thank you Phone #: ###-#### Inspection requested via web by Lea Briggs- furnace ac coil co ok
MEC18-03169 Final7/13/20187/13/20187/13/2018 2:46:04 PMPPASS
Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace ac coil co ok
MEC18-03169 Pressure Test7/13/20187/13/20187/13/2018 2:17:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Justin Osterhout- 5lb flue pressure test ok- 20lb gas pressure test ok
MEC18-03311 Final7/12/20187/13/20187/13/2018 1:45:32 PMPNR
Please call on way: Joseph ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC18-03311 Pressure Test7/13/20187/13/20187/13/2018 1:45:23 PMPPASS
Please call on way: Joseph ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- 5lb flue pressure test ok
MEC18-03273 Rough-in7/12/20187/13/20187/13/2018 12:52:25 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- supply run upstairs in loft is kinked/ smashed- supply run into laundry is kinked- supply run into west upstairs bedroom kinked by truss- return into master is kinked-return into east upstairs bedroom kinked- need to seal end cap on ducting at furnace
MEC18-03273 Pressure Test7/12/20187/13/20187/13/2018 12:42:34 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pressure test ok
MEC18-01723 Final7/12/20187/13/20187/13/2018 11:44:24 AMAPASS
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok- need RM permit to be finaled before full final
MEC17-05257 Final7/12/20187/13/20187/13/2018 11:43:51 AMAPASS
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- final ok need RM mechanical permit to be finaled before full final
MEC18-03050 Rough-in7/12/20187/13/20187/13/2018 11:42:45 AMPPART
Contact Name: Aaron Roberts Duct rough-in Phone #: ###-#### Inspection requested via web by RM Mechanical- duct work ok for insulation
MEC18-03267 Pressure Test7/10/20187/13/20187/13/2018 11:15:21 AMAFAIL
Please call Breaganat ###-#### - to coordinate. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- 5lb flue pressure test fail gauge was at zero- A/C fuse size to large- need drip leg in gas line at furnace- need co detectors installed- need to see combustion air ran to furnace-
MEC18-02433 Final7/6/20187/13/20187/13/2018 10:29:11 AMAFAIL
Please call when in route to home at ###-#### Phone #: ###-#### Inspection requested via web by Carolyn Rudd- lineset insulation in basment needs to be tape where old lineset and new meet- secondary drain needs a wet switch cant not drain into primary and pump
MEC18-03268 Final7/11/20187/13/20187/13/2018 10:08:43 AMAFAIL
homeowner # ###-#### - michael
thank you! Phone #: ###-#### Inspection requested via web by Aaron Alandt- need to place another combustion air vent in door( front of furnace)- lineset has a rip in the insulation above the water heater- above the water heater has building insulation touching the common vent(flue) need 1" clearances- lineset is also within 1" of the furnace flue near the water heater- A/C breaker size is too large needs to be a 25amp
MEC18-03303 Final7/11/20187/13/20187/13/2018 9:48:19 AMAFAIL
Please call home owner Dr Byrd or Jessica at ###-#### when in route to home. Phone #: ###-#### Inspection requested via web by Carolyn Rudd- need to see co detectors in house - call back in inspection when co are installed
MIS18-00257 MEC-Conference7/11/20187/13/20187/13/2018 9:27:32 AMADONE
MEC17-03505 Mec-Aging Inspection7/13/20187/13/20187/13/2018 8:22:06 AM DONE
called A-1 to schedule inspection with homeowner
MEC18-03218 Final7/12/20187/13/20187/13/2018 7:56:50 AMAPASS
Please call Dan at ###-#### with a 30 minute heads up arrival time. Phone #: ###-#### Inspection requested via web by David or K Cole- lineset penetration sealed ok- ac coil co ok
MEC17-04742 DOC - Permit Finaled7/13/20187/13/20187/13/2018 7:54:58 AMPPASS
final ok
MEC17-04742 Mec-Aging Inspection7/13/20187/13/20187/13/2018 7:54:08 AM DONE
MEC18-03273 Pressure Test7/12/20187/13/20187/12/2018 2:37:07 PMACANC
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves
MEC18-03273 Rough-in7/12/20187/13/20187/12/2018 2:37:06 PMACANC
Phone #: ###-#### >> Inspection requested via web by Gary Reeves Inspection cancelled from web by: Gary Reeves