Inspections for the day of: Thursday, July 2, 2020.
Number of inspections: 26
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-02704 Final7/2/20207/2/20207/2/2020 3:04:20 PMPFAIL
Just a final inspection needed on the range vent Cole wants to meet you there please call ahead Phone #: ###-#### Inspection requested via web by Derrick Nalley
- need range hood installation instructions onsite
-talked with Cole
MEC20-02680 Final7/1/20207/2/20207/2/2020 2:47:42 PMPCANC
Please inspect PM and call Brett on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
-per installer
MEC20-02696 Final7/2/20207/2/20207/2/2020 2:28:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- A/C breaker is oversized should be 30amps
- pictures will be ok
MEC20-02635 Final7/2/20207/2/20207/2/2020 2:09:54 PMPPASS
Please call Eric at ###-#### with a 30 minute heads up arrival time.
Thank you! Phone #: ###-#### Inspection requested via web by David or K Cole
- A/C coil only co ok
MEC20-02657 Final6/29/20207/2/20207/2/2020 1:53:59 PMPPASS
IF AT ALL POSSIBLE HOMEOWNER DIANE IS ASKING FOR LATER PM APPT PLEASE, ANYTIME AFTER 2P. SHE UNDERSTANDS THAT CANNOT BE GUARANTEED. PLEASE CALL DIANE WHEN IN ROUTE. HAVE A GREAT WEEKEND! Phone #: ###-#### Inspection requested via web by Rick Montgomery
- furnace ac coil co ok
MEC20-01405 Final7/2/20207/2/20207/2/2020 1:34:27 PMPPASS
MEC20-01307 Final7/1/20207/2/20207/2/2020 1:25:48 PMPPASS
Field super: Daryl Thomas
gate code 1957 Phone #: ###-#### Inspection requested via web by Lisa Whitney
- final ok
MEC20-01641 Rough-in7/1/20207/2/20207/2/2020 1:25:20 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- R/I ok
MEC20-01641 Pressure Test7/1/20207/2/20207/2/2020 1:24:51 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 20lb gas test ok
- tagged meter location
MEC20-02231 Rough-in7/1/20207/2/20207/2/2020 1:06:01 PMPPASS
field super; Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- R/I ok
MEC20-02231 Pressure Test7/1/20207/2/20207/2/2020 1:05:48 PMPPASS
field super; Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- 20lb gas test ok
- tagged meter location
MEC20-02585 Final7/1/20207/2/20207/2/2020 12:36:22 PMAPASS
INSTALLER JAROD WILL MEET YOU ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 5lb flue test ok
- furnace ac coil co ok
MEC20-01479 Final7/1/20207/2/20207/2/2020 12:14:00 PMAPASS
KEITH IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
MEC19-05140 Final7/1/20207/2/20207/2/2020 12:13:49 PMAPASS
KEITH IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
MEC20-02086 Final7/1/20207/2/20207/2/2020 11:56:21 AMAFAIL
Please use access code 4888 Phone #: ###-#### Inspection requested via web by Sarah Small
- fees need paid
MEC20-01848 Final7/1/20207/2/20207/2/2020 11:22:58 AMAPASS
Phone #: ###-#### Inspection requested via web by Randy Hart
- final ok
MEC20-02689 Final6/30/20207/2/20207/2/2020 10:47:27 AMAFAIL
New fireplace inspection Phone #: ###-#### Inspection requested via web by John Menzel
- fireplace framing need to be per instructions 49" wide with 1/2" clearances on sides
- gas piping needs to be rigid into fireplace cabinet
- venting termination needs to terminate outside and above existing chimney cap
MEC20-02703 Rough-in7/1/20207/2/20207/2/2020 10:22:46 AMAFAIL
Ducting, Drier, bath fans and ducting. Phone #: ###-#### Inspection requested via web by Eric Sonner
- approved man j onsite
-dryer wall needs furred out
- dryer termination needs screen removed and ducting sealed
-access opening for furnace 20x30
MEC20-01823 Rough-in7/1/20207/2/20207/2/2020 10:22:23 AMAFAIL
Ducting, Drier bath fans, and new equipment Phone #: ###-#### Inspection requested via web by Eric Sonner
- approved man j onsite
-dryer wall needs furred out
- dryer termination needs screen removed
-access opening for furnace 20x30
MEC20-02453 Final7/1/20207/2/20207/2/2020 9:27:24 AMAPASS
please call john prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige
- tab report
- final ok
MEC20-02378 Final7/1/20207/2/20207/2/2020 9:27:06 AMAPASS
please call John prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige
- final ok
MEC20-01506 Conference7/1/20207/2/20207/2/2020 8:36:17 AMAPASS
8:30 duct blast Phone #: ###-#### Inspection requested via web by Debbie Marino
- duct blast ok
MEC19-04016 Mec-Aging Inspection7/2/20207/2/20207/2/2020 8:05:51 AM PASS
Doc Permit Expired ok
MEC19-04016 DOC - Permit Expired7/2/20207/2/20207/2/2020 8:05:42 AMAPASS
Doc Permit Expired ok permit not active
MEC19-05320 Mec-Aging Inspection7/2/20207/2/20207/2/2020 8:05:09 AM FAIL
Permit has not been active since being issued on 11-22-19. Schedule inspection with owner if work is finished. Permit will expire at next mechanical aging inspection if not active.
MEC20-01590 Conference6/30/20207/2/20207/1/2020 10:06:26 AMACANC
8:30 Duct Blast Phone #: ###-#### >> Inspection requested via web by Debbie Marino Inspection cancelled from web by: Debbie Marino