Inspections for the day of: Tuesday, August 14, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03914 Final8/10/20188/14/20188/14/2018 4:20:22 PMPPASS
Field Super: Chad Robertson Phone #: ###-#### Inspection requested via web by Lisa Whitney
- RTU final ok
MIS18-00046 MEC-Conference8/14/20188/14/20188/14/2018 3:19:58 PMPFAIL
per Jim Storey-work being done w/o permits
- Mechanical permit will be required for exhaust fans that will need to be installed in bathrooms and the ductless split system on the north side of the house
MEC18-03961 Final8/14/20188/14/20188/14/2018 2:53:09 PMPFAIL
Landlord Charlene Bragg lives next door at 3605 W Normandie Dr if no one answers door at 3602. Her number is ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- insulation in the crawl space in touching furnace B vent- need b vent clearances of 1"
everything else checked out ok
MEC18-03894 Final8/14/20188/14/20188/14/2018 2:31:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette- A/C coil co ok
MEC18-03675 Rough-in8/10/20188/14/20188/14/2018 2:21:15 PMPFAIL
Steve-call for access code Phone #: ###-####- need a drip leg in gas line at furnace- B vent coming through floor needs 1" clearances- furnace needs service discconect and light in crawl- access opening into crawl is too small needs to be 22x 30 - make sure that toe kicks in two locations are ducted all the way to the register- need to see 6" fresh air intake
MEC18-03968 Final8/14/20188/14/20188/14/2018 1:29:11 PMPPASS
Please call on way: Tyrel ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss- A/C coil co ok
MEC18-03809 Rough-in8/13/20188/14/20188/14/2018 11:50:05 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
-need to perform a flue pressure test on both furnace and water heater
- duct seal at bypass damper both return and supply side
MEC18-03809 Pressure Test8/13/20188/14/20188/14/2018 11:48:25 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- need to perform 5lb flue test on both water heater and furnace
- 20lb gas pressure test ok
MEC18-03810 Rough-in8/13/20188/14/20188/14/2018 11:47:31 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves
- line set insulation has rips
-trunk line duct work in attic needs insulation wrap
-duct seal at bypass both return and supply
- water heater 5lb flue test under 5lb
MEC18-03810 Pressure Test8/13/20188/14/20188/14/2018 11:45:36 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- water heater 5lb flue test fail gauge was under 5lb and wouldnt zero- 20lb gas pressure test ok- furnace 5lb flue test ok
MEC18-03014 Final8/13/20188/14/20188/14/2018 10:47:57 AMAPASS
PLEASE CALL JIM (LEAD INSTALLER) AT ###-####, HE NEEDS A HOUR NOTICE TO MEET YOU THERE.

IF YOU HAVE ANY QUESTIONS PLEASE CALL JIM.

THANKS

MARY JANE Phone #: ###-#### Inspection requested via web by Trina DeBoard
-final ok
MEC18-02236 Rough-in8/13/20188/14/20188/14/2018 10:31:57 AMAFAIL
Call for access Phone #: 2088718789 >> Inspection requested via mobile web by Albert
- light test fail- also need clearances on exhuast fans to make-up unit on roof- a beam on the back side of the hood is within 18 " of hood top
MEC18-03932 Final8/13/20188/14/20188/14/2018 9:14:44 AMAPASS
Please call John at ###-#### when in route, customer is going out of town so much do inspection in the am the earlier the better please. Phone #: ###-#### Inspection requested via web by Sabrina DeHority
-furnace ac coil co ok
MEC18-03545 Final8/14/20188/14/20188/14/2018 8:47:37 AMAPASS
needed this inspection in the am not pm
- 5lb flue pressure test ok- furnace ac coil co ok
MEC17-05308 Mec-Aging Inspection8/14/20188/14/20188/14/2018 8:27:23 AM DONE
called TML to schedule inspection.
MEC18-03545 Final8/7/20188/14/20188/14/2018 8:24:35 AMPCANC
Carlon will be there by 10am to do the flue test. Phone #: ###-#### Inspection requested via web by Amber Orr
- cancelled this pm inspection and scheduled for am
MEC18-03545 Conference8/14/20188/14/20188/14/2018 8:23:03 AMACANC
needed this inspection in the am not pm
MEC18-03545 Final8/14/20188/14/20188/14/2018 8:21:40 AMPCANC
needed to this inspection to be am not pm
MEC18-03932 Final8/13/20188/14/20188/13/2018 10:17:58 AMPCANC
Call Doug at ###-#### to coordinate - installing a/c in the am please call Doug when in route. Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority
MEC18-03932 Final8/10/20188/14/20188/13/2018 10:14:47 AMACANC
Please call John at ###-#### when in route - customer is going out of town so need to have inspection done in the early morning please. Phone #: ###-#### >> Inspection requested via web by Sabrina DeHority Inspection cancelled from web by: Sabrina DeHority