Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02055 Final8/9/20198/9/20198/9/2019 3:47:48 PMPPASS
Call Max if you need anything ###-#### Inspection requested via web by Floyd Floyd Peek
- final ok
MEC19-03166 Rough-in8/9/20198/9/20198/9/2019 3:29:14 PMPFAIL
UNITS 103K, 104P,105P,106Q,203K,204P,205V,302S Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- all fireplaces need secured to framing
- all fireplaces need saw dust/ buidling materials cleaned off top of fireplace
- all fireplaces need romex wiring on back of fireplace secured so fireplace has 1/2 clearances on back
-106 needs firestop/ venting installed properly as to acheive 3" clearances on top of venting to required frame out in wall
MEC19-01155 Rough-in8/9/20198/9/20198/9/2019 3:23:22 PMPPASS
Soffit inspection in condo 203. Tyson is the contact Phone #: ###-#### Inspection requested via web by stan lillquist
-R/I duct seal 203 ok
MEC19-03526 Rough-in8/8/20198/9/20198/9/2019 2:02:03 PMPPASS
pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston
- R/I ok
MEC19-03526 Pressure Test8/9/20198/9/20198/9/2019 2:01:46 PMPPASS
pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston
- 5lb flue pressure test ok
-20lb gas pressure test ok
- tagged meter location
MEC19-02964 Rough-in8/9/20198/9/20198/9/2019 1:38:32 PMPPASS
Rough-in for rest of the all duct work and seal inspection. Phone #: ###-#### Inspection requested via web by adrian manzo
- duct seal on the rest of the building ok
- ok for duct insulation
- exhaust fans will be done by next inspection
- dryer vents will be going out building sidewall below ceiling estimate of 6-8' of duct per the general
- range hoods are going to be changed to 200 cfm each per the general
- dishwasher hood will not be needed since appliance manufacture specs dont require it per the general. will need those installation instructions on side for inspecting
MEC19-03158 Final8/9/20198/9/20198/9/2019 1:27:09 PMPPASS
PLEASE CALL CONTRACTOR JEFF @ # LISTED WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- R/I ok
MEC19-01623 Conference8/8/20198/9/20198/9/2019 1:25:37 PMPDONE
Contact owner for entry 2083538112 Phone #: ###-#### Inspection requested via web by bob pond
MEC19-03300 Pressure Test8/8/20198/9/20198/9/2019 12:13:37 PMAPASS
Please inspect in the late AM.
Customer: Frank ; Linda ###-####
HVAC: Ari ###-####
Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- 20lb gas pressure test ok
MEC19-03252 Rough-in8/7/20198/9/20198/9/2019 10:43:38 AMAPASS
Please call Kevin at least 30 min prior to inspection. He requested a cover and I believe that is part of a rough in. Phone #: ###-#### Inspection requested via web by Rhonda Marcum
- R/I ok ceiling cover ok
MEC19-01413 Pressure Test8/8/20198/9/20198/9/2019 10:34:06 AMAPASS
please call brandon with questions Phone #: ###-#### Inspection requested via web by Nicholas Paige
-60lb gas pressure test ok
- tagged meter location
MEC18-05418 Final8/8/20198/9/20198/9/2019 10:05:26 AMACANC
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
MEC18-05418 Conference8/9/20198/9/20198/9/2019 10:05:14 AMAPASS
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
MEC19-00096 Final8/8/20198/9/20198/9/2019 10:04:55 AMACANC
Duct blast witness 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
MEC19-00096 Conference8/9/20198/9/20198/9/2019 10:04:38 AMAPASS
Duct blast witness 9am Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
MEC19-01513 Final8/8/20198/9/20198/9/2019 8:56:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft
- fireplace final ok
MEC19-03424 Final8/7/20198/9/20198/9/2019 8:48:37 AMAFAIL
Please call Mitchell at ###-#### when heading there. Thank you Phone #: ###-#### Inspection requested via web by Scott Wickstrom
- A/C fuse sizes need to be 35amp
MEC19-03486 Final8/8/20198/9/20198/9/2019 8:18:13 AMANR
Please inspect Later AM and call Joseph on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- not ready reschedule
MEC19-03269 Pressure Test8/8/20198/9/20198/9/2019 8:14:36 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
- 5lb flue pressure test ok
-20lb gas pressure test ok
- tagged meter location
MEC19-03269 Rough-in8/8/20198/9/20198/9/2019 8:14:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves
- R/I ok
MEC18-06138 Mec-Aging Inspection8/9/20198/9/20198/9/2019 7:59:48 AM PASS
doc permit finaled
MEC18-06138 DOC - Permit Finaled8/9/20198/9/20198/9/2019 7:59:37 AMAPASS
doc permit finaled ok
MEC18-06132 Mec-Aging Inspection8/9/20198/9/20198/9/2019 7:59:07 AM PASS
permit expired ok
MEC18-06132 DOC - Permit Expired8/9/20198/9/20198/9/2019 7:58:45 AMAPASS
permit expire ok permit not active