MEC19-02055
| Final | 8/9/2019 | 8/9/2019 | 8/9/2019 3:47:48 PM | P | PASS |
|
|
Call Max if you need anything ###-#### Inspection requested via web by Floyd Floyd Peek - final ok
|
MEC19-03166
| Rough-in | 8/9/2019 | 8/9/2019 | 8/9/2019 3:29:14 PM | P | FAIL |
|
|
UNITS 103K, 104P,105P,106Q,203K,204P,205V,302S Phone #: ###-#### Inspection requested via web by Sheldon Lebow - all fireplaces need secured to framing - all fireplaces need saw dust/ buidling materials cleaned off top of fireplace - all fireplaces need romex wiring on back of fireplace secured so fireplace has 1/2 clearances on back -106 needs firestop/ venting installed properly as to acheive 3" clearances on top of venting to required frame out in wall
|
MEC19-01155
| Rough-in | 8/9/2019 | 8/9/2019 | 8/9/2019 3:23:22 PM | P | PASS |
|
|
Soffit inspection in condo 203. Tyson is the contact Phone #: ###-#### Inspection requested via web by stan lillquist -R/I duct seal 203 ok
|
MEC19-03526
| Rough-in | 8/8/2019 | 8/9/2019 | 8/9/2019 2:02:03 PM | P | PASS |
|
|
pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston - R/I ok
|
MEC19-03526
| Pressure Test | 8/9/2019 | 8/9/2019 | 8/9/2019 2:01:46 PM | P | PASS |
|
|
pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston - 5lb flue pressure test ok -20lb gas pressure test ok - tagged meter location
|
MEC19-02964
| Rough-in | 8/9/2019 | 8/9/2019 | 8/9/2019 1:38:32 PM | P | PASS |
|
|
Rough-in for rest of the all duct work and seal inspection. Phone #: ###-#### Inspection requested via web by adrian manzo - duct seal on the rest of the building ok - ok for duct insulation - exhaust fans will be done by next inspection - dryer vents will be going out building sidewall below ceiling estimate of 6-8' of duct per the general - range hoods are going to be changed to 200 cfm each per the general - dishwasher hood will not be needed since appliance manufacture specs dont require it per the general. will need those installation instructions on side for inspecting
|
MEC19-03158
| Final | 8/9/2019 | 8/9/2019 | 8/9/2019 1:27:09 PM | P | PASS |
|
|
PLEASE CALL CONTRACTOR JEFF @ # LISTED WHEN EN ROUTE Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING - R/I ok
|
MEC19-01623
| Conference | 8/8/2019 | 8/9/2019 | 8/9/2019 1:25:37 PM | P | DONE |
|
|
Contact owner for entry 2083538112 Phone #: ###-#### Inspection requested via web by bob pond
|
MEC19-03300
| Pressure Test | 8/8/2019 | 8/9/2019 | 8/9/2019 12:13:37 PM | A | PASS |
|
|
Please inspect in the late AM. Customer: Frank ; Linda ###-#### HVAC: Ari ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 20lb gas pressure test ok
|
MEC19-03252
| Rough-in | 8/7/2019 | 8/9/2019 | 8/9/2019 10:43:38 AM | A | PASS |
|
|
Please call Kevin at least 30 min prior to inspection. He requested a cover and I believe that is part of a rough in. Phone #: ###-#### Inspection requested via web by Rhonda Marcum - R/I ok ceiling cover ok
|
MEC19-01413
| Pressure Test | 8/8/2019 | 8/9/2019 | 8/9/2019 10:34:06 AM | A | PASS |
|
|
please call brandon with questions Phone #: ###-#### Inspection requested via web by Nicholas Paige -60lb gas pressure test ok - tagged meter location
|
MEC18-05418
| Final | 8/8/2019 | 8/9/2019 | 8/9/2019 10:05:26 AM | A | CANC |
|
|
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves - duct blast ok
|
MEC18-05418
| Conference | 8/9/2019 | 8/9/2019 | 8/9/2019 10:05:14 AM | A | PASS |
|
|
Duct Blast witness @ 9am Phone #: ###-#### Inspection requested via web by Gary Reeves - duct blast ok
|
MEC19-00096
| Final | 8/8/2019 | 8/9/2019 | 8/9/2019 10:04:55 AM | A | CANC |
|
|
Duct blast witness 9am Phone #: ###-#### Inspection requested via web by Gary Reeves - duct blast ok
|
MEC19-00096
| Conference | 8/9/2019 | 8/9/2019 | 8/9/2019 10:04:38 AM | A | PASS |
|
|
Duct blast witness 9am Phone #: ###-#### Inspection requested via web by Gary Reeves - duct blast ok
|
MEC19-01513
| Final | 8/8/2019 | 8/9/2019 | 8/9/2019 8:56:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace final ok
|
MEC19-03424
| Final | 8/7/2019 | 8/9/2019 | 8/9/2019 8:48:37 AM | A | FAIL |
|
|
Please call Mitchell at ###-#### when heading there. Thank you Phone #: ###-#### Inspection requested via web by Scott Wickstrom - A/C fuse sizes need to be 35amp
|
MEC19-03486
| Final | 8/8/2019 | 8/9/2019 | 8/9/2019 8:18:13 AM | A | NR |
|
|
Please inspect Later AM and call Joseph on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - not ready reschedule
|
MEC19-03269
| Pressure Test | 8/8/2019 | 8/9/2019 | 8/9/2019 8:14:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - 5lb flue pressure test ok -20lb gas pressure test ok - tagged meter location
|
MEC19-03269
| Rough-in | 8/8/2019 | 8/9/2019 | 8/9/2019 8:14:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves - R/I ok
|
MEC18-06138
| Mec-Aging Inspection | 8/9/2019 | 8/9/2019 | 8/9/2019 7:59:48 AM | | PASS |
|
|
doc permit finaled
|
MEC18-06138
| DOC - Permit Finaled | 8/9/2019 | 8/9/2019 | 8/9/2019 7:59:37 AM | A | PASS |
|
|
doc permit finaled ok
|
MEC18-06132
| Mec-Aging Inspection | 8/9/2019 | 8/9/2019 | 8/9/2019 7:59:07 AM | | PASS |
|
|
permit expired ok
|
MEC18-06132
| DOC - Permit Expired | 8/9/2019 | 8/9/2019 | 8/9/2019 7:58:45 AM | A | PASS |
|
|
permit expire ok permit not active
|