MEC18-04507
| Rough-in | 9/17/2018 | 9/17/2018 | 9/17/2018 4:37:04 PM | P | FAIL |
|
|
mec and firepl Phone #: ###-#### Inspection requested via web by Oleg Chervak - line set has rip in the insulation at the top of the wall -supply trunk in the attic needs insulated -crawl not finished -insulation sheild in the attic for the water heater need to be centered around the pipe to maintain 1" clearances -fire caulk around fireplace vent needs to be sealed -fresh air for the furnace is terminating out the soffit and will need a fire damper or terminate side wall( WUI Zone A) - flex runs need to be installed per Manuf. spec the inner liner needs to be taped and the outer liner needs to be zip tied. One of the flex runs for an exhaust fan was not connected and not sealed with tape
|
MEC18-04507
| Pressure Test | 9/17/2018 | 9/17/2018 | 9/17/2018 4:25:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pressure test ok
|
MEC18-04298
| Rough-in | 9/17/2018 | 9/17/2018 | 9/17/2018 3:59:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
MEC18-00675
| Final | 9/10/2018 | 9/17/2018 | 9/17/2018 2:59:26 PM | P | FAIL |
|
|
Please call John 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby- need 1" clearances around b vent and ceiling- need to install co detectors upstairs near bedrooms and the co detector downstairs need to be in the hallway not the laundry room
|
MEC18-04447
| Final | 9/12/2018 | 9/17/2018 | 9/17/2018 2:44:49 PM | P | PASS |
|
|
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
|
MEC18-03574
| Final | 9/17/2018 | 9/17/2018 | 9/17/2018 2:36:27 PM | P | PASS |
|
|
Contact: Robert Church ###-#### Phone #: ###-#### Inspection requested via web by Brent Lacy- gas piping final ok
|
MEC18-04465
| Final | 9/14/2018 | 9/17/2018 | 9/17/2018 2:28:57 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- need a drip leg after shut off valve on gas line- b vent needs 1" clearances to duct work insulation at furnace
|
MEC17-01386
| Rough-in | 9/17/2018 | 9/17/2018 | 9/17/2018 2:08:52 PM | P | FAIL |
|
|
Scott Phone #: ###-####- dryer vent needs to be smooth pipe- water heater needs 3" clearances on horizantal runs and 1" clearances on vertical- condensates need to be finished- there is also two more ductless splits that need installed for R/I cover-southside still has an exhaust fan that needs vented and a ductless split that needs condensate finished- need to look into the HVAC contractors permit for the multiport ductless that is finished-
|
MEC17-04462
| Mec-Aging Inspection | 9/17/2018 | 9/17/2018 | 9/17/2018 10:33:15 AM | | CANC |
|
|
|
MEC16-04910
| Mec-Aging Inspection | 9/17/2018 | 9/17/2018 | 9/17/2018 10:32:35 AM | | DONE |
|
|
while talking with the homeowner during the fireplace final he said there was still some work being done on other half of the house- WIP
|
MEC18-04460
| Rough-in | 9/15/2018 | 9/17/2018 | 9/17/2018 10:23:19 AM | A | NR |
|
|
house is vacancy lock box #5134 Phone #: ###-#### Inspection requested via web by thomas nguyen- corrections were made and are ok- need to see the water heater b vent fastened down so that 1" clearances are maintained- also want to see wall framed in that the dryer vent runs into
|
MEC18-03759
| Final | 9/11/2018 | 9/17/2018 | 9/17/2018 10:05:38 AM | A | PASS |
|
|
This is a Flue Pressure and Final Inspect. Please meet our installer at home at 10:00 AM. Contact for Right Now is Mary ###-####
Phone #: ###-#### Inspection requested via web by Mary LaFayette - 5lb flue pressure test ok- furnace only co ok
|
MEC18-04049
| Rough-in | 9/14/2018 | 9/17/2018 | 9/17/2018 9:45:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero- fireplace R/I ok- still need to see gasline R/I to fireplace do not cover until gasline has been inspected
|
MEC18-04298
| Rough-in | 9/14/2018 | 9/17/2018 | 9/17/2018 9:13:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- water heater flue needs a insulation sheild in the attic- would like to see clearances on the b vent for the water heater in the attic- where the flue turns a 90 elbow in the attic is hard to see clearances to combustilbes
|
MEC18-04298
| Pressure Test | 9/14/2018 | 9/17/2018 | 9/17/2018 9:11:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pressure test ok- 5lb flue pressure test ok
|
MEC18-04482
| Pressure Test | 9/14/2018 | 9/17/2018 | 9/17/2018 7:15:28 AM | A | CANC |
|
|
Thanks >> Inspection requested via web by Floyd Floyd Peek Inspection cancelled from web by: Floyd Floyd Peek
|
MEC18-04482
| Rough-in | 9/14/2018 | 9/17/2018 | 9/17/2018 7:15:22 AM | A | CANC |
|
|
>> Inspection requested via web by Floyd Floyd Peek Inspection cancelled from web by: Floyd Floyd Peek
|