Inspections for the day of: Wednesday, September 18, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-02440 Final9/11/20199/18/20199/18/2019 4:04:55 PMPNH
PLEASE CALL TENANT LEXI @ # LISTED WHEN EN ROUTE. PLEASE COME AS EARLY AS POSSIBLE IN THE P.M. DUE TO GRAVEYARD SHIFT @ WRK. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- no access to home left notice on front door
MEC19-03944 Final9/11/20199/18/20199/18/2019 3:15:57 PMPPASS
INSTALLER JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace ac coil co ok
MEC19-04136 Final9/18/20199/18/20199/18/2019 2:41:57 PMPPASS
if you could call Sonia when you head her way that would be great..###-####. Thank you Phone #: ###-#### Inspection requested via web by Kim Evans
- air handler coil HP ok
MEC19-00588 Final9/18/20199/18/20199/18/2019 2:18:53 PMPDONE
Please attempt inspection., I have had no contact back from homeowner. Nick Brown ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
- Renter answered door but didn't want to let me into house. Gave renter a notice and asked if she could give this information to the owners of the house.
MEC19-00240 Pressure Test9/18/20199/18/20199/18/2019 2:08:00 PMPPASS
Contact: Robert Church ###-####.

Pressure test for 2nd and 3rd floor area B. Phone #: ###-#### Inspection requested via web by Brent Lacy
- 60lb gas pressure test on mains 2rd and 3th floor area A&B ok
MEC19-03970 Pressure Test9/18/20199/18/20199/18/2019 1:04:50 PMPFAIL
Call when you are on the way Phone #: ###-#### Inspection requested via web by Dan McFate
- 20lb gas pressure test fail
MEC19-03107 Rough-in9/17/20199/18/20199/18/2019 11:55:43 AMAPASS
Izzy Phone #: ###-####
- R/I ok
MEC18-04138 Final9/17/20199/18/20199/18/2019 11:43:18 AMAPASS
Call half hour before to meet//
Brent Phone #: ###-####
- final ok
MEC19-01922 Final9/17/20199/18/20199/18/2019 11:27:03 AMAFAIL
Please call when you are on the way so we can make sure someone is home or we can meet you there Phone #: ###-#### Inspection requested via web by Dan McFate
- need to see co sensors installed near bedrooms
- primary drain on indoor coil needs repaired and glued
- secondary drain needs a wet switch installed
- pump tubing installed is too close to single wall furnace flue. Keep in mind clearances to combustibles on furnace flue
MEC19-03559 Final9/11/20199/18/20199/18/2019 11:10:35 AMAFAIL
Please call Frank ###-#### in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout
- need to see electrical permit issued
- need to add furnace to permit
MEC19-03559 Pressure Test9/18/20199/18/20199/18/2019 11:09:19 AMAPASS
Please call Frank ###-#### in route to inspection Phone #: ###-#### Inspection requested via web by Justin Osterhout
- 5lb flue pressure test ok
MEC19-04145 Rough-in9/18/20199/18/20199/18/2019 10:56:42 AMAPASS
Shawn Phone #: ###-####
- R/I on range/make up air and dryer ok
- need to see dryer vent added to permit by final
MEC19-02781 Final9/16/20199/18/20199/18/2019 10:34:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Denise Colin
- furnace only co ok
MEC19-02781 Pressure Test9/16/20199/18/20199/18/2019 10:33:56 AMAPASS
Phone #: ###-#### Inspection requested via web by Denise Colin
- 5lb flue pressure test ok
MEC19-03937 Final9/17/20199/18/20199/18/2019 10:16:43 AMAPASS
Please call owner prior to arrival - Leon Colllins. Owner has user manual. Phone #: ###-#### Inspection requested via web by Jamee Shoecraft
- fireplace final ok
MEC19-04052 Rough-in9/17/20199/18/20199/18/2019 9:59:26 AMAPASS
PLEASE CALL CONTRACTOR NATE WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
- R/I ok
MEC19-04052 Pressure Test9/18/20199/18/20199/18/2019 9:59:12 AMAPASS
PLEASE CALL CONTRACTOR NATE WHEN EN ROUTE. Phone #: ###-#### Inspection requested via web by SOPHIA FLEMING
-20lb gas pressure test ok
MEC19-00588 Mec-Aging Inspection9/18/20199/18/20199/18/2019 9:43:41 AM DONE
Called Mary at Right Now heating and talked about this mechanical aging permit.This permit has not been active since 2-8-19 when it was issued. Mary stated that they have tried to contact owners with no response. Schedule inspection at location and I will attempt contact with owners.
MEC19-00589 Mec-Aging Inspection9/18/20199/18/20199/18/2019 9:43:12 AM DONE
Called Mary at Right Now heating and talked about this mechanical aging permit.This permit has not been active since 2-8-19 when it was issued. Mary stated that they have tried to contact owners with no response. Schedule inspection at location and I will attempt contact with owners.
MEC19-04145 Final9/17/20199/18/20199/18/2019 12:00:00 AMACANC
**SHOULD HAVE BEEN A ROUGH IN*** Please call the phone number provided when on the way. Phone #: ###-#### >> Inspection requested via web by Steve Bunch