Inspections for the day of: Wednesday, September 5, 2018.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04319 Final9/5/20189/5/20189/5/2018 4:05:50 PMPFAIL
Please inspect after 3:15. Emily ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- line set penetration needs sealed
MEC18-03964 Final8/29/20189/5/20189/5/2018 3:08:45 PMPNH
Please call Tim 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby- no access
MEC18-03571 Final9/5/20189/5/20189/5/2018 3:07:37 PMPFAIL
need clearances for furnace flue change single wall pipe out for double wall and support pipe so it doesn't fall against wall. double wall pipe needs to mainatin 1" clearances to combustibles
MEC18-03487 Final9/5/20189/5/20189/5/2018 3:07:11 PMPCANC
Please call 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby- this inspection should have been for 2810 malibu across the street- this inspection will be scheduled for Oct sometime
MEC18-01156 Final9/5/20189/5/20189/5/2018 2:31:35 PMPNH
No contact with these people even after a certified letter was sent. Please stop by and leave a note. Phone #: ###-#### Inspection requested via web by Mary LaFayette
- no access left notice on front door
MEC18-04327 Pressure Test9/4/20189/5/20189/5/2018 2:11:34 PMPFAIL
GATE CODE #2390
INSTALLER ANAS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 20lb gas pressure test fail gauge would not zero
MEC18-03983 Final9/4/20189/5/20189/5/2018 1:37:42 PMPPASS
final - call luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
MEC18-03983 Card not on site to sign9/5/20189/5/20189/5/2018 1:37:34 PMPPASS
final - call luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok
MEC18-04035 Final9/5/20189/5/20189/5/2018 1:36:50 PMPPASS
Please call Tony 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby
MEC18-04238 Rough-in9/4/20189/5/20189/5/2018 11:29:12 AMAPASS
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
- R/I ok
MEC18-04238 Pressure Test9/4/20189/5/20189/5/2018 11:28:56 AMAPASS
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
- 20lb gas pressure test ok-5lb flue pressure test ok
MEC18-04044 Rough-in9/4/20189/5/20189/5/2018 11:17:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC18-04193 Final9/4/20189/5/20189/5/2018 10:46:33 AMAFAIL
final - call RJ 1/2 hour before inspection so we can have someone on-site Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- need to see a 20lb gas pressure test on gas line- line set needs insulation installed through wall penetration and sealed- need to install wet switch on secoundary- home needs co detectors installed near bedrooms- electrical contractor needs to run weather tight conduit for A/C disconnect- add other to permit for new duct work
MEC17-05520 Final9/4/20189/5/20189/5/2018 10:09:02 AMAFAIL
Phone #: ###-#### Inspection requested via web by Joseph Profitt-
- range vent cant be flex needs to be smooth ducting- lineset penetration needs sealed- A/C breaker size needs to be a 15amp- couldnt find duct blast sticker
MEC16-05348 Mec-Aging Inspection9/5/20189/5/20189/5/2018 9:55:12 AM DONE
WIP
MEC18-04245 Final9/4/20189/5/20189/5/2018 9:32:13 AMAFAIL
Please call ahead for access - Edwin Phone #: ###-####- need to seal line set penetration- need UV protection on line set- need a drip leg installed on gas line- b vent in crawl needs 3 " clearances to supply duct insulation- need to install 2 co detectors
MEC18-03487 Final8/29/20189/5/20189/5/2018 9:03:10 AMANH
Please call 30 min prior to arrival Phone #: ###-#### Inspection requested via web by Andrea Grigsby- no access
MEC17-01753 Mec-Aging Inspection9/5/20189/5/20189/5/2018 8:52:20 AM NH
left notice on front door- permit expires in Nov 2018
MEC17-02895 Mec-Aging Inspection9/5/20189/5/20189/5/2018 8:33:43 AM DONE
called Advanced to schedule inspection
MEC18-02476 Final9/4/20189/5/20189/5/2018 8:21:39 AMACANC
107,108,207,208,307,308 Phone #: ###-#### Inspection requested via web by Gary Reeves
- rescheduled ductblast and finals
MEC18-02222 Final9/4/20189/5/20189/5/2018 8:19:04 AMAPASS
Jonny Phone #: ###-####
MEC17-04300 Mec-Aging Inspection9/5/20189/5/20189/5/2018 8:09:13 AM CANC
MEC18-03958 Final8/29/20189/5/20188/30/2018 2:52:55 PMACANC
Phone #: ###-#### >> Inspection requested via web by Mary LaFayette Inspection cancelled from web by: Mary LaFayette