MIS19-00329
| BLD-Conference | 10/2/2019 | 10/2/2019 | 10/2/2019 4:14:04 PM | P | DONE |
|
|
Interior remodel without permits.//red tag issued to obtain permits//will check back 1 week//
|
BLD19-03727
| BLD-Final | 10/2/2019 | 10/2/2019 | 10/2/2019 4:13:24 PM | P | PASS |
|
|
Please call 30 minutes before arrival if possible so I can meet you there Phone #: ###-#### Inspection requested via web by Joseph knight//final complete//had contractor add smoke and CO detectors for code compliance//
|
BLD19-03727
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 4:12:44 PM | P | PASS |
|
|
|
BLD19-01949
| BLD-Framing/Rough-in | 10/1/2019 | 10/2/2019 | 10/2/2019 3:58:19 PM | A | FAIL |
|
|
call 30 mins before // dowel Phone #: ###-####//need electrical sign off//fire proofing at can lights not approved--use approved fire proofing//call for re-inspection//
|
BLD19-01949
| BLD-Footing | 10/1/2019 | 10/2/2019 | 10/2/2019 3:57:10 PM | P | PASS |
|
|
Doyle-please call when on way Phone #: ###-####//ok to pour//special inspection was performed for dowels epoxied into footing//
|
BLD19-00654
| BLD-Final | 10/2/2019 | 10/2/2019 | 10/2/2019 3:32:48 PM | P | PASS |
|
|
Karen Phone #: ###-####//electrical complete//sign installed//
|
BLD19-00654
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 3:32:29 PM | P | PASS |
|
|
|
BLD19-03124
| BLD-Wall Bracing | 10/2/2019 | 10/2/2019 | 10/2/2019 1:55:22 PM | P | FAIL |
|
|
shear // Gary Phone #: ###-####//need to verify hold downs with engineer--STHD 14 specified and not used//nail shear walls or provide alternative from engineer//portal frame needs nailed 3" oc//
|
BLD18-03121
| BLD-Final | 10/2/2019 | 10/2/2019 | 10/2/2019 1:30:29 PM | P | CANC |
|
|
Matt Phone #: ###-####//cancel per Matt//
|
BLD19-03627
| BLD-Final | 10/2/2019 | 10/2/2019 | 10/2/2019 12:42:54 PM | P | PASS |
|
|
Steve Phone #: ###-####//items required on application have been met//no changes have been done on tennant space//space was unfurnished at time of inspection//
|
BLD19-02392
| BLD-Final | 10/1/2019 | 10/2/2019 | 10/2/2019 12:23:46 PM | P | PASS |
|
|
Replace 3 Jacksons wall sign with new Extra Mile signs. All Primary power by others Phone #: ###-#### Inspection requested via web by Ken Olsen//electrical final complete//signs are installed on building in an enclosed housing//final complete//
|
BLD19-02392
| DOC - Permit Finaled | 10/2/2019 | 10/2/2019 | 10/2/2019 12:22:52 PM | P | PASS |
|
|
|
BLD18-01781
| BLD-Aging Inspection | 10/2/2019 | 10/2/2019 | 10/2/2019 11:43:21 AM | | PASS |
|
|
Expires: 11/17/19
|
BLD19-02307
| BLD-Foundation | 10/1/2019 | 10/2/2019 | 10/2/2019 10:43:10 AM | A | PASS |
|
|
jerry Phone #: ###-####
|
BLD19-02420
| BLD-Wall Bracing | 10/1/2019 | 10/2/2019 | 10/2/2019 10:07:16 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle//exterior wall bracing only//will need to check LIB at framing inspection//ok to wrap and install windows//
|
BLD19-02420
| BLD-Wall Bracing | 10/1/2019 | 10/2/2019 | 10/2/2019 9:54:45 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Joel Hirtle//two inspections scheduled for Wall bracing//
|
BLD19-03663
| BLD-Final | 9/30/2019 | 10/2/2019 | 10/2/2019 9:24:53 AM | A | NR |
|
|
Joan Phone #: ###-####//single action door handle will be installed tomorrow//will reshedule for PM//
|
BLD19-02594
| BLD-Final | 10/1/2019 | 10/2/2019 | 10/2/2019 9:10:09 AM | A | FAIL |
|
|
jose Phone #: ###-####//correction notice issued for steel cable railing and steel post supports//door also needs sealed and finished//electrical permit and inspection required for add light fixtures//
|