MIS18-00458
| MIS-Aging Inspection | 11/12/2019 | 11/12/2019 | 11/13/2019 8:25:12 AM | | CANC |
|
|
|
BLD19-03123
| BLD-Final | 11/12/2019 | 11/12/2019 | 11/12/2019 3:48:01 PM | P | PASS |
|
|
Gary Phone #: ###-####//corrections made//final complete//
|
BLD19-03123
| DOC - Permit Finaled | 11/12/2019 | 11/12/2019 | 11/12/2019 3:47:40 PM | P | PASS |
|
|
|
BLD19-03124
| BLD-Final | 11/12/2019 | 11/12/2019 | 11/12/2019 3:40:09 PM | P | PASS |
|
|
Gary Phone #: ###-####//framing corrections made//final complete//
|
BLD19-03124
| DOC - Permit Finaled | 11/12/2019 | 11/12/2019 | 11/12/2019 3:39:44 PM | P | PASS |
|
|
|
BLD19-03006
| BLD-Wall Bracing | 11/12/2019 | 11/12/2019 | 11/12/2019 3:17:53 PM | P | FAIL |
|
|
Jeff Phone #: ###-####//add approved fasteners to sill plate around building//add nails per detail to blocking and sill plate at portal frame//correction notice posted//
|
BLD19-03448
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 2:49:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Michael La Pointe
|
BLD19-03448
| DOC - Permit Finaled | 11/12/2019 | 11/12/2019 | 11/12/2019 2:49:04 PM | P | PASS |
|
|
|
BLD19-02220
| BLD-Final | 11/12/2019 | 11/12/2019 | 11/12/2019 2:48:48 PM | P | PASS |
|
|
Tom ###-####//ok per plans//furniture supplied by tennant--cabinets on plans ok--service counter and work space on plans--additional cabinets supplied by tennant//
|
BLD19-03693
| BLD-Footing | 11/12/2019 | 11/12/2019 | 11/12/2019 2:13:24 PM | P | PASS |
|
|
Brian Phone #: ###-####
|
BLD19-02981
| BLD-Ceiling Grid Inspection | 11/12/2019 | 11/12/2019 | 11/12/2019 1:30:00 PM | P | PART |
|
|
John Craft ###-####//suite 100 ok pending mechanical//fire caulk penetrations that appear to be in a fire wall//will check when grid for 150 is ready//
|
BLD19-02836
| BLD-Final | 11/8/2019 | 11/12/2019 | 11/12/2019 12:57:14 PM | P | FAIL |
|
|
Angela Phone #: ###-#### cAROLINE###-#### PLEASE CALL FOR ACCESS CODE//smoke detectors outside bedrooms need to be combos//1 per floor//
|
BLD19-04073
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 12:32:09 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Dexter
|
BLD19-04073
| DOC - Permit Finaled | 11/12/2019 | 11/12/2019 | 11/12/2019 12:31:55 PM | P | PASS |
|
|
|
BLD19-00553
| BLD-Conference | 11/12/2019 | 11/12/2019 | 11/12/2019 12:15:58 PM | P | DONE |
|
|
Correction notice issued//no isnpections have been requested for the addtion of the pole structure//structure is almost complete//will need verification of required footings///
|
BLD19-02700
| BLD-Wall Bracing | 11/8/2019 | 11/12/2019 | 11/12/2019 11:59:44 AM | A | FAIL |
|
|
shear // Matt Phone #: ###-####//need plan mod for changes in shear locations--provide updated engineering as all shear walls are engineered//add hold downs at garage PFH per plans//
|
BLD19-03992
| BLD-Foundation | 11/11/2019 | 11/12/2019 | 11/12/2019 11:25:21 AM | A | PART |
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru//ok per plans//still reccomend discussing issue with irrigation pipe with pipe owner//pour at own risk until issue resolved//
|
BLD19-02398
| BLD-Foundation | 11/8/2019 | 11/12/2019 | 11/12/2019 10:55:59 AM | A | PASS |
|
|
Dane Phone #: ###-####//ok pending specials//
|
BLD18-02896
| BLD-Aging Inspection | 11/12/2019 | 11/12/2019 | 11/12/2019 10:19:27 AM | | DONE |
|
|
Expires: 12/28/19
|
BLD18-02635
| BLD-Aging Inspection | 11/12/2019 | 11/12/2019 | 11/12/2019 10:17:35 AM | | DONE |
|
|
|
BLD19-03464
| BLD-Framing/Rough-in | 11/11/2019 | 11/12/2019 | 11/12/2019 10:13:56 AM | A | FAIL |
|
|
Rough framing/Sheer wall inspection to allow us to cover with house wrap. Phone #: ###-#### Inspection requested via web by greg bauer//no plans onsite///please have plans located onsite for all inspections//
|
BLD19-03555
| BLD-Foundation | 11/11/2019 | 11/12/2019 | 11/12/2019 10:02:38 AM | A | PART |
|
|
Stemwall is formed and ready for inspection. Concrete blankets draped over forms Phone #: ###-#### Inspection requested via web by Christian Mikesell//ok when rebar clearances fixed//discussed anchor bolts for hold downs per engineering//
|
BLD18-04238
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 9:34:22 AM | A | CANC |
|
|
Please give a 15-20 minute notice so I can leave work. Phone #: ###-#### Inspection requested via web by David Vanlydegraf
|
BLD18-03045
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 9:28:54 AM | A | NR |
|
|
Call prior to going Phone #: 2089493426 >> Inspection requested via mobile web by Paul Nesbitt//parking lot is not done//shell is not complete//need fire life safety//
|
BLD19-00839
| BLD-Blower Door Test Results | 11/12/2019 | 11/12/2019 | 11/12/2019 9:03:02 AM | P | DONE |
|
|
4.3 ACH50
|
BLD19-00839
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 9:01:30 AM | A | PASS |
|
|
Please call me for garage code. Thanks! Phone #: ###-#### Inspection requested via web by Aron Mock
|
BLD19-00839
| DOC - Permit Finaled | 11/12/2019 | 11/12/2019 | 11/12/2019 9:00:39 AM | P | PASS |
|
|
|
BLD19-00647
| BLD-Final | 11/11/2019 | 11/12/2019 | 11/12/2019 8:44:54 AM | A | NR |
|
|
Please call for garage code. Thanks! Phone #: ###-#### Inspection requested via web by Aron Mock//needs mechanical final passed//
|