Inspections for the day of: Thursday, November 14, 2019.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS18-00354 MIS-Aging Inspection11/14/201911/14/201911/15/2019 8:27:25 AM CANC
BLD18-04477 BLD-Aging Inspection11/14/201911/14/201911/15/2019 8:26:40 AM PASS
needed DOC final//per Jim Sly final complete when electrical had passed//
BLD19-03692 BLD-Final11/14/201911/14/201911/14/2019 4:30:54 PMPPASS
Mike- if possible please give 30 min ahead call Phone #: ###-####//special inspection report provided//exterior complete//door was fixed for proper operation//
BLD19-03692 DOC - Permit Finaled11/14/201911/14/201911/14/2019 4:29:53 PMPPASS
BLD19-02398 BLD-Energy code compliance11/14/201911/14/201911/14/2019 4:11:55 PMPPART
Foundation insulation, late PM if possible. Phone #: ###-#### Inspection requested via web by Michael McHargue//ok per plan//will need to add 2' return under slab per drawings//
BLD18-02051 BLD-Final11/14/201911/14/201911/14/2019 3:53:04 PMPNR
call for access // Michael Phone #: ###-####//needs blower door test//
BLD19-01380 BLD-Wall Bracing11/14/201911/14/201911/14/2019 3:28:59 PMPFAIL
Phone #: ###-#### Inspection requested via web by Braden Holbrook//no plans onsite//
BLD18-02912 BLD-Wall Bracing11/14/201911/14/201911/14/2019 3:25:29 PMPPASS
Phone #: ###-#### Inspection requested via web by Braden Holbrook//corrections made//
BLD19-03532 BLD-Framing/Rough-in11/14/201911/14/201911/14/2019 3:13:22 PMPFAIL
Ed Phone #: ###-####//remove wrap for shear inspection//expose wall sill plates for anchor bolt inspection//add kings stud per details//add A35 per details//sthd14s needed at all location noted on plans//CN posted//
BLD08-00243 BLD-Final11/13/201911/14/201911/14/2019 2:38:00 PMPPASS
David Phone #: ###-####//added smoke carbon monoxide combos--ok//fixed electrical cover//final appears to be complete--old permit no plans//
BLD08-00243 DOC - Permit Finaled11/14/201911/14/201911/14/2019 2:37:03 PMPPASS
BLD19-03157 BLD-Framing/Rough-in11/13/201911/14/201911/14/2019 2:21:26 PMAPART
Santiago Phone #: ###-####/frame ok-need to add ADA backing//need mechanical rough in inspection prior to insulating//pending mechanical rough in pass//
BLD19-03693 BLD-Foundation11/14/201911/14/201911/14/2019 2:19:39 PMPPASS
Brian- pouring at 3pm Phone #: ###-####
BLD19-01303 BLD-Footing11/14/201911/14/201911/14/2019 12:53:20 PMPPART
As early as possible Phone #: 2089656103 >> Inspection requested via mobile web by Alvaro//cabana and planter footings--ok per plans//pending specials if required//setbacks surveyed in and per plans//
BLD19-00889 BLD-Blower Door Test Results11/14/201911/14/201911/14/2019 11:57:54 AMPDONE
4.45 ACH 50
BLD19-00889 BLD-Final11/13/201911/14/201911/14/2019 11:56:40 AMPPASS
Alex Phone #: ###-####///corrections made//
BLD19-00889 DOC - Permit Finaled11/14/201911/14/201911/14/2019 11:56:22 AMPPASS
BLD19-03261 BLD-Framing/Rough-in11/13/201911/14/201911/14/2019 11:43:56 AMPPASS
PJ Phone #: ###-####//corrections made//still need safety glazing--check at final//ok to insulate//
BLD18-04238 BLD-Framing/Rough-in11/14/201911/14/201911/14/2019 11:26:46 AMPPASS
For framing inspection. Phone #: ###-#### Inspection requested via web by David Vanlydegraf//ok--need to insulate attic space as it will not be accessible for blow in//call for energy//
BLD19-02981 BLD-Ceiling Grid Inspection11/14/201911/14/201911/14/2019 10:36:24 AMAPASS
Phone #: ###-#### Inspection requested via web by Jonathan Craft//2nd half of grid ok//
BLD19-04195 BLD-Energy code compliance11/13/201911/14/201911/14/2019 10:12:42 AMAPASS
Lucas Phone #: ###-####
BLD19-04099 BLD-Framing/Rough-in11/13/201911/14/201911/14/2019 9:46:06 AMAPASS
As early as possible Phone #: 2085149738 >> Inspection requested via mobile web by Brent Anderson
BLD19-03424 BLD-Final11/13/201911/14/201911/14/2019 9:19:46 AMAPASS
James Phone #: ###-####
BLD19-03424 DOC - Permit Finaled11/14/201911/14/201911/14/2019 9:19:36 AMPPASS
BLD19-00647 BLD-Blower Door Test Results11/14/201911/14/201911/14/2019 9:05:16 AMPDONE
6.9 ACH50
BLD19-00647 BLD-Final11/13/201911/14/201911/14/2019 9:03:30 AMAPASS
Call if need garage door code. Thanks! Phone #: ###-#### Inspection requested via web by Aron Mock
BLD19-00647 DOC - Permit Finaled11/14/201911/14/201911/14/2019 9:03:04 AMPPASS