BLD19-03015
| BLD-Framing/Rough-in | 11/8/2019 | 11/8/2019 | 11/8/2019 4:38:45 PM | P | PART |
|
|
Bob Phone #: ###-####//footing depth verified//electrical permit issued//framing member per engineering--knee braces need 3.5" at through bolts--verify with engineer or change to meet drawings//
|
BLD18-00829
| BLD-Wall Bracing | 11/8/2019 | 11/8/2019 | 11/8/2019 4:27:04 PM | P | PASS |
|
|
|
BLD18-00829
| BLD-Conference | 11/7/2019 | 11/8/2019 | 11/8/2019 4:26:06 PM | P | CANC |
|
|
ready for framing inspection so I can cover and begin roof, windows, doors, and siding installation. I will be onsite from one until 4:30 pm, thanks Paul Phone #: ###-#### Inspection requested via web by J Goll//needs shear inspection//
|
BLD19-03992
| BLD-Footing | 11/8/2019 | 11/8/2019 | 11/8/2019 3:18:13 PM | P | PART |
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron//irrigation pipe on west side--discussed with zoning and is not listed on plans or plat//currently footing ok per approved plans--notified owner of pipe being next to footings--owner will notify/meet with irrigation pipe owner//pouring at own risk with irrigation pipe located next to footings//
|
BLD19-03802
| BLD-Concrete | 11/7/2019 | 11/8/2019 | 11/8/2019 2:07:57 PM | P | PASS |
|
|
East mechanical pad, west and north aprons Phone #: ###-#### Inspection requested via web by Jared Waggoner//ok per plans and engineering//maintain clearances on rebar in turned down footings//pending specials//
|
BLD19-00362
| BLD-Wall Bracing | 11/7/2019 | 11/8/2019 | 11/8/2019 1:27:57 PM | P | PART |
|
|
Troy Phone #: ###-####//add screws at bottom of shear panels as discussed--guys working on when I left//
|
BLD19-03123
| BLD-Final | 11/8/2019 | 11/8/2019 | 11/8/2019 12:41:53 PM | P | FAIL |
|
|
Gary Phone #: ###-####//CN posted--need to add nails 6d 4" oc for shear on gypsum board//
|
BLD19-03954
| BLD-Final | 11/7/2019 | 11/8/2019 | 11/8/2019 12:21:37 PM | A | PASS |
|
|
Please call ###-#### for Karl. Phone #: ###-#### Inspection requested via web by Coulton Main//final electrical complete--install ok per approved plans//
|
BLD19-03954
| DOC - Permit Finaled | 11/8/2019 | 11/8/2019 | 11/8/2019 12:21:00 PM | P | PASS |
|
|
|
BLD19-02981
| BLD-Ceiling Grid Inspection | 11/8/2019 | 11/8/2019 | 11/8/2019 11:57:03 AM | P | NR |
|
|
John Phone #: ###-####//need fire sprinkler pass//
|
BLD19-00843
| BLD-Framing/Rough-in | 11/7/2019 | 11/8/2019 | 11/8/2019 11:31:17 AM | A | PART |
|
|
Zach Phone #: ###-####//need to provide mod for construction changes to ramp//vestibule, bathrooms ok when fire sprinklers have passed--discussed with Troy and advised Zach to schedule fire conference for areas behind rock walls//
|
BLD19-04431
| BLD-Final | 11/7/2019 | 11/8/2019 | 11/8/2019 11:29:24 AM | A | FAIL |
|
|
Victoria Phone #: ###-####//window next double patio door will need to be tempered on side that is within 2 feet of door per code//discussed with owner//
|
BLD19-04294
| BLD-Final | 11/7/2019 | 11/8/2019 | 11/8/2019 11:20:40 AM | A | NR |
|
|
Salam Phone #: ###-####//need fire life safety final//
|
BLD19-01820
| BLD-Wall Bracing | 11/7/2019 | 11/8/2019 | 11/8/2019 10:47:11 AM | A | PASS |
|
|
shear // willy Phone #: ###-####//corrections made//nails will be changed to 10D per simpson on HTT5s//check at framing//
|
BLD19-03992
| BLD-Footing | 11/7/2019 | 11/8/2019 | 11/8/2019 10:35:54 AM | A | CANC |
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|
BLD19-03717
| BLD-Foundation | 11/7/2019 | 11/8/2019 | 11/8/2019 10:26:49 AM | A | PASS |
|
|
Nick- foundation wall inspection-Concrete at 11am (was infrom that time is not guaranteed) Phone #: ###-####
|
BLD18-02912
| BLD-Wall Bracing | 11/7/2019 | 11/8/2019 | 11/8/2019 8:57:22 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Braden Holbrook//add nails to portal frame westside--add approved nails to sill plate//leave access to verify nails at framing//
|
BLD18-02274
| BLD-Aging Inspection | 11/8/2019 | 11/8/2019 | 11/8/2019 8:26:35 AM | | DONE |
|
|
Expires: 12/23/19
|
BLD19-02039
| BLD-Aging Inspection | 11/8/2019 | 11/8/2019 | 11/8/2019 8:26:02 AM | | DONE |
|
|
Expires: 12/24/19
|
BLD19-00538
| BLD-Concrete | 11/7/2019 | 11/8/2019 | 11/7/2019 5:20:13 PM | A | CANC |
|
|
Pouring the walls for the garage at 2pm. please inspect as close to that time frame as possible. Thanks Phone #: ###-#### >> Inspection requested via web by Matt Perry Inspection cancelled from web by: Matt Perry
|