MIS19-00022
| MIS-Aging Inspection | 12/30/2019 | 12/30/2019 | 12/31/2019 7:22:50 AM | | DONE |
|
|
house has been demolished//
|
BLD19-01686
| BLD-Final | 12/30/2019 | 12/30/2019 | 12/30/2019 4:35:59 PM | P | PASS |
|
|
Garage 3162 Phone #: ###-#### Inspection requested via web by Kelly Stover//corrections made//
|
BLD19-01686
| DOC - Permit Finaled | 12/30/2019 | 12/30/2019 | 12/30/2019 4:35:43 PM | P | PASS |
|
|
|
BLD19-03701
| BLD-Wall Bracing | 12/30/2019 | 12/30/2019 | 12/30/2019 4:35:29 PM | P | PART |
|
|
Mark Phone #: ###-####//exterior ok//will need to make corrections to interior shear locations--check at framing//
|
BLD19-01150
| BLD-Framing/Rough-in | 12/30/2019 | 12/30/2019 | 12/30/2019 3:00:45 PM | P | FAIL |
|
|
Phone #: 2085149240 >> Inspection requested via mobile web by Andy//need to fireblock penetrations in top and bottom plates//complete air seal//obtain mechanical permit and rough in inspection//CN posted//
|
BLD19-01860
| BLD-Wall Bracing | 12/30/2019 | 12/30/2019 | 12/30/2019 2:31:11 PM | P | PART |
|
|
craig Phone #: ###-####//area near stairs first floor needs blocked and screwed at 4 in oc//all other areas ok//
|
BLD19-02406
| BLD-Concrete | 12/27/2019 | 12/30/2019 | 12/30/2019 2:00:29 PM | P | PEND |
|
|
This is for CMU bar and Grout placement at first 4'' Lift. MTI on board for observation and inspection. Ready at 2:00 pm tentatively Any questions please feel free to call me at anytime. Thank You, Phone #: ###-#### Inspection requested via web by Ron Oswald//added bar in areas needed per plans//pend specials //
|
BLD19-02869
| BLD-Final | 12/30/2019 | 12/30/2019 | 12/30/2019 1:21:24 PM | P | NR |
|
|
Tom Phone #: ###-####//need special isnpection report//talked with Tom, may need to have pull test as no specials were completed, he will talk with design engineer//
|
BLD19-04340
| BLD-Final | 12/30/2019 | 12/30/2019 | 12/30/2019 12:58:28 PM | P | PASS |
|
|
Tom Phone #: ###-####
|
BLD19-04852
| BLD-Framing/Rough-in | 12/27/2019 | 12/30/2019 | 12/30/2019 12:58:10 PM | A | PASS |
|
|
Lynn Phone #: ###-####
|
BLD19-02700
| BLD-Wall Bracing | 12/27/2019 | 12/30/2019 | 12/30/2019 12:11:58 PM | P | FAIL |
|
|
Brandon Phone #: ###-####//need to add nails for 4" pattern per plans//add blocks and nails at edges on garage//
|
BLD19-00676
| BLD-Final | 12/27/2019 | 12/30/2019 | 12/30/2019 11:06:55 AM | A | PASS |
|
|
Call for access Pete Phone #: ###-####//corrections made and final complete//
|
BLD19-00676
| DOC - Permit Finaled | 12/30/2019 | 12/30/2019 | 12/30/2019 11:06:36 AM | P | PASS |
|
|
|
BLD19-04507
| BLD-Foundation | 12/27/2019 | 12/30/2019 | 12/30/2019 11:06:07 AM | A | DEFR |
|
|
dane Phone #: ###-####//foundation was not inspected and poured//contractor assumes all liability//
|
BLD19-03956
| BLD-Final | 12/27/2019 | 12/30/2019 | 12/30/2019 10:22:11 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Scott Smith//roof appears to be installed within code requirements//
|
BLD19-03956
| DOC - Permit Finaled | 12/30/2019 | 12/30/2019 | 12/30/2019 10:21:44 AM | P | PASS |
|
|
|
BLD19-04380
| BLD-Framing/Rough-in | 12/27/2019 | 12/30/2019 | 12/30/2019 9:20:45 AM | A | CANC |
|
|
Please call Brian Prussia with any questions or concerns at 208.241.5835 Phone #: ###-#### Inspection requested via web by BRS Permitting// No work needed to the existing roof structure per engineer’s roof evaluation.//
|
BLD12-00075
| BLD-Concrete | 12/28/2019 | 12/30/2019 | 12/30/2019 9:19:56 AM | A | PART |
|
|
A pour is planned for 9 am this is not a footer pour. The pour is for the base of the overflow containment trough that runs around two sides of the external storage tank pad. A rebar inspection was performed and passed by MTI. MTI and RSCI QC will be onsite to collect cylinders and to monitor concrete specifications. It would be a good time to visit about what kind of inspections the City wants to perform. This is a small job but there will be numerous small pours. This pour is 6cy. Phone #: ###-#### Inspection requested via web by John Cloninger//met onsite with GC//specials onsite rebar approved per specials, ok pending all specials//blankets and ground heater onsite//
|