Inspections for the day of: Wednesday, February 12, 2020.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD19-02407 BLD-Footing2/12/20202/12/20202/12/2020 3:56:37 PMPNR
Sergio Phone #: ###-####//frost is still present//
BLD20-00137 BLD-Footing2/12/20202/12/20202/12/2020 3:44:52 PMPNR
Sergio Phone #: ###-####//still has frozen ground//
BLD19-02667 BLD-Footing2/12/20202/12/20202/12/2020 3:44:16 PMPNR
Sergio Phone #: ###-####//still has frozen ground//
BLD19-04669 BLD-Footing2/11/20202/12/20202/12/2020 3:41:45 PMPPART
Pat Phone #: ###-####//Wip//bar installed//string set for easment, building appears to be outside of easment line based on strings set by contractor//no frost observed onsite at time of isnpection//blankets onsite//
BLD19-00843 BLD-Final2/11/20202/12/20202/12/2020 3:26:36 PMPPASS
Phone #: ###-#### Inspection requested via web by Zach Carter
BLD19-02398 BLD-Wall Bracing2/11/20202/12/20202/12/2020 1:47:24 PMPPART
RE-INSPECTION for completed Items including noted strapping at windows per details on plans ; noted truss blocking per truss details and plans at strapping required on roof decking. Phone #: ###-#### Inspection requested via web by Wes Harrison//truss blocking installed//strapping installed and nailed per plans// exterior nailing and shear ok//
BLD19-00239 BLD-Final2/11/20202/12/20202/12/2020 12:56:39 PMPPASS
Drew Phone #: ###-####//final complete smoke and co detectors installed//garage separation wall taped//
BLD19-00239 DOC - Permit Finaled2/12/20202/12/20202/12/2020 12:56:23 PMPPASS
BLD19-03493 BLD-Final2/11/20202/12/20202/12/2020 12:37:15 PMPNR
Marcus Phone #: ###-####///needs fire life safety final complete prior to final building inspection//
BLD19-04743 BLD-Footing2/11/20202/12/20202/12/2020 11:55:04 AMPFAIL
Brian Phone #: ###-####//1/2 of footings subgrade frozen//
BLD19-04306 BLD-Final2/11/20202/12/20202/12/2020 11:39:45 AMANR
Dean Phone #: ###-####
MIS20-00045 BLD-Conference2/12/20202/12/20202/12/2020 10:43:23 AMPCANC
follow up on CN....
MIS20-00045 BLD-Conference2/12/20202/12/20202/12/2020 10:41:40 AMPDONE
Per Brian Mechanical Inspector, no permit for framing on outside flue Phone #: ###-####//CN left with owner//need permit for chase for mechanical vent, will need to expose framing for inspection building and mechanical//also noted that permit for interior remodel will be needed if more than cosmetic//appears to be mechanical, electrical and plumbinng permits for interior remodel//follow up 10 days//
BLD19-04031 BLD-Energy code compliance2/11/20202/12/20202/12/2020 10:33:45 AMAPASS
Jeff Phone #: ###-####
BLD19-04725 BLD-Wall Bracing2/11/20202/12/20202/12/2020 10:29:29 AMAPART
Brian Phone #: ###-####//interior shear wall only//will need to see verification that hold downs were installed//
BLD19-03656 BLD-Wall Bracing2/11/20202/12/20202/12/2020 9:27:01 AMAFAIL
Vince Phone #: ###-####//still need to install straping//portal frame still needed//CN still stands until all corrections made//site contact was informed to complete all corrections and call for re-inspection when complete//
BLD19-04033 BLD-Framing/Rough-in2/11/20202/12/20202/12/2020 9:09:08 AMAPASS
Jeff Phone #: ###-####//most corrections made//still need to add nails to truss scabs per engineering//ok to insulate//
BLD18-01778 BLD-Aging Inspection2/12/20202/12/20202/12/2020 8:21:53 AM DONE
Expires: 03/29/20
BLD18-01768 BLD-Aging Inspection2/12/20202/12/20202/12/2020 8:21:05 AM CANC