Inspections for the day of: Friday, May 8, 2020.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS20-00134 BLD-Conference5/5/20205/8/20205/12/2020 9:14:37 AMADONE
2nd follow up//talked with worker, said owner is working on permits, and may have already submitted for review//check back 10 days//
BLD19-03992 BLD-Final5/8/20205/8/20205/8/2020 3:23:29 PMPPASS
call for access - screened // Willy Phone #: ###-####//remove dust cover on smoke detector and post insulation cert//all other areas ok//
BLD19-03992 DOC - Permit Finaled5/8/20205/8/20205/8/2020 3:22:53 PMPPASS
BLD19-04013 BLD-Other5/8/20205/8/20205/8/2020 3:22:31 PMPCANC
rough to cover // Matt Phone #: ###-####//not ready, need to have rough ins inspected in areas wanting to cover for soffits//
BLD19-04385 BLD-Final5/7/20205/8/20205/8/2020 2:45:49 PMPNR
Phone #: ###-#### Inspection requested via web by John Treat//see CN posted onsite//
BLD19-03180 BLD-Energy code compliance5/7/20205/8/20205/8/2020 12:58:26 PMAPART
Firewall insulation Inspection requested via web by Carl Funk//fire separation walls only//per plans//
BLD19-03181 BLD-Energy code compliance5/7/20205/8/20205/8/2020 12:58:12 PMAPART
Firewall Insulation Inspection requested via web by Carl Funk//fire separation walls only//per plans//
BLD19-03187 BLD-Energy code compliance5/7/20205/8/20205/8/2020 12:57:58 PMAPART
Firewall insulation Inspection requested via web by Carl Funk//fire separation walls only//per plans//
BLD19-03188 BLD-Energy code compliance5/7/20205/8/20205/8/2020 12:57:41 PMAPART
Inspection requested via web by Carl Funk//fire separation walls only//per plans//
BLD19-03188 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 12:57:00 PMAPART
Inspection requested via web by Carl Funk//fire separation wall only//Corrections made//need rating information for ele heater box in rated wall(all Units)//
BLD19-03180 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 12:56:37 PMAPART
Firewall Inspection requested via web by Carl Funk//fire separation wall only//Corrections made//need rating information for ele heater box in rated wall(all Units)//
BLD19-03181 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 12:56:18 PMAPART
Firewall blocking Inspection requested via web by Carl Funk//fire separation wall only//Corrections made//need rating information for ele heater box in rated wall(all Units)//
BLD19-03187 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 12:55:56 PMAPART
Fireblocking Inspection requested via web by Carl Funk//fire separation wall only//Corrections made//need rating information for ele heater box in rated wall(all Units)//
BLD19-04600 BLD-Energy code compliance5/8/20205/8/20205/8/2020 12:33:56 PMPFAIL
Alex - Gates close at 2pm Phone #: ###-####//door in kithchen needs to swing in direction on plans and have landing//need to install R49 insulaton in attic//add vapor barrier at exterior walls per plans//
MIS20-00051 BLD-Conference4/24/20205/8/20205/8/2020 11:58:01 AMADONE
follow up//discussed with supervisor that no building permit has been issued//sent email with photos and MIS information//
BLD19-04366 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 11:16:47 AMANR
call to meet / Melvin Phone #: ###-####//need to add blocking and nail sheathing where roof meets exisitng//add strap per detail//check trusses on next inspection//
BLD19-03256 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 10:17:43 AMAPEND
Inspection requested via web by Carl Funk//fire separation only//corrections made//need rating for ele heater in separation wall(all Units)//pending ele rough//
BLD19-03255 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 10:17:23 AMAPEND
Inspection requested via web by Carl Funk//fire separation only//corrections made//need rating for ele heater in separation wall(all Units)//pending ele rough//
BLD19-03254 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 10:16:25 AMAPEND
Fireblocking Inspection requested via web by Carl Funk//fire separation only//corrections made//need rating for ele heater in separation wall(all Units)//pending ele rough//
BLD19-03257 BLD-Framing/Rough-in5/7/20205/8/20205/8/2020 10:07:22 AMAPART
Inspection requested via web by Carl Funk//fire separation walls only//need verification on fire rating on heater box(all units)//other corrections made//ok to insulate fire separation walls only//
BLD19-03659 BLD-Final5/7/20205/8/20205/8/2020 8:53:40 AMAPASS
garage code 3162 Phone #: ###-#### Inspection requested via web by Kelly Stover
BLD19-03659 DOC - Permit Finaled5/8/20205/8/20205/8/2020 8:52:44 AMPPASS
BLD19-03659 BLD-Blower Door Test Results5/7/20205/8/20205/8/2020 8:42:59 AMACANC
BLD20-00376 BLD-Foundation5/7/20205/8/20205/7/2020 12:00:00 AMACANC
Jay *screened* Phone #: ###-####