BLD20-00250
| BLD-Aging Inspection | 7/27/2020 | 7/27/2020 | 7/28/2020 7:20:11 AM | | PEND |
|
|
looks like occupant is talking with plan review for requirements to continue occupying the space//
|
BLD19-00817
| BLD-Aging Inspection | 7/27/2020 | 7/27/2020 | 7/28/2020 7:18:26 AM | | PEND |
|
|
no isnpections requested
|
BLD19-03547
| BLD-Aging Inspection | 7/27/2020 | 7/27/2020 | 7/28/2020 7:17:48 AM | | PEND |
|
|
no inspections requested
|
BLD20-02348
| BLD-Footing | 7/27/2020 | 7/27/2020 | 7/27/2020 4:39:13 PM | P | NR |
|
|
Screened- please call ahead- Zach Phone #: ###-####//used as a conference//
|
BLD20-02185
| BLD-Wall cover | 7/27/2020 | 7/27/2020 | 7/27/2020 3:32:15 PM | P | NR |
|
|
call for access - screened // Justin Phone #: ###-####//need plumbing permit, need electrical rough in inspection//
|
BLD20-01121
| BLD-Energy code compliance | 7/27/2020 | 7/27/2020 | 7/27/2020 3:15:26 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Vaughn Pruett//mechanical failed//
|
BLD19-04369
| BLD-Foundation | 7/27/2020 | 7/27/2020 | 7/27/2020 2:27:37 PM | P | PEND |
|
|
Sergio - Foundation walls are outside of the modified footing area. */Screened*/ Phone #: ###-####//special inspection report, for post installed anchors, verified by pull test, was in compliance with design engineer--also engineer called me and verified// //plans show hair pins at corners with hold down anchor bolts--engineer called and wants detail deleted from plans--advised to submit with current plan mod under review for footings// //let GC know about my concerns with elevations, we discussed elevtations, wall height seems extremely high, wall currently 2' 8" above footing, plans show a 2' wall on structurals, will need to meet accessiblity requirements at finals// //if walls are poured prior to acceptance of plan modification for footing changes and wall details, cantractor is pouring at own risk// rebar appears to be installed per the current plans, less the hair pins on corners//
|
BLD20-00225
| BLD-Energy code compliance | 7/24/2020 | 7/27/2020 | 7/27/2020 1:24:18 PM | A | PASS |
|
|
screened // Vinnie Phone #: ###-####
|
BLD20-00223
| BLD-Final | 7/24/2020 | 7/27/2020 | 7/27/2020 1:00:03 PM | P | FAIL |
|
|
Robert - */Screened*/ Phone #: ###-####//plumbing inspection was canceled--need to have final complete//plans show R49 attic insulation, tag show R38 was installed//remove dust covers from smoke detectors//
|
BLD20-00223
| BLD-Blower Door Test Results | 7/27/2020 | 7/27/2020 | 7/27/2020 12:58:50 PM | P | DONE |
|
|
5.1 ACH 50
|
BLD19-03475
| BLD-Conference | 7/20/2020 | 7/27/2020 | 7/27/2020 11:50:54 AM | A | DONE |
|
|
follow up on addition to home without proper permits////talekd with Asaad, he has made contact for plan modificaton requirements// on the phone he stated he would be submitting the plan mdoification//let him know it needs to be completed prior to continuing any work//follow up 5 days//
|
BLD20-01877
| BLD-Final | 7/22/2020 | 7/27/2020 | 7/27/2020 10:48:08 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by BRS Permitting
|
BLD20-01877
| DOC - Permit Finaled | 7/27/2020 | 7/27/2020 | 7/27/2020 10:47:54 AM | P | PASS |
|
|
|
BLD20-01857
| BLD-Final | 7/24/2020 | 7/27/2020 | 7/27/2020 9:28:33 AM | A | NH |
|
|
MAIN CONTACT - Levi Henry ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting//called Levi, asked me to knock for home owner//no answer at door//will need to schedule when access to plans and backyard is available//
|
BLD19-01246
| BLD-Aging Inspection | 7/27/2020 | 7/27/2020 | 7/27/2020 7:35:26 AM | | PEND |
|
|
|
MIS20-00211
| BLD-Conference | 7/13/2020 | 7/27/2020 | 7/27/2020 7:34:04 AM | A | DONE |
|
|
follow up on permits //BLD is in issued status//will keep MIS open for trades//
|