Inspections for the day of: Thursday, August 8, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD18-03122 BLD-Energy code compliance8/8/20198/8/20198/9/2019 8:09:25 AMPPASS
Matt Phone #: ###-####//framing corrections made//107,108,207,208,307,308 only//
BLD18-04248 BLD-Framing/Rough-in8/6/20198/8/20198/8/2019 2:48:36 PMAPASS
Larry Phone #: ###-####
BLD19-02383 BLD-Footing8/8/20198/8/20198/8/2019 2:10:12 PMPPASS
surgeo Phone #: ###-####
BLD19-01257 BLD-Wall Bracing8/7/20198/8/20198/8/2019 12:43:18 PMAPASS
LOYD Phone #: ###-####//shear nailing ok on exterior walls//crew is working on interior (garage) shear wall-check blocking at framing//
MIS19-00218 BLD-Conference7/25/20198/8/20198/8/2019 11:56:26 AMADONE
follow up on occupancy//correction notice issued on 7/25/2019//permit was applied for//
MIS19-00218 DOC - Permit Finaled8/8/20198/8/20198/8/2019 11:56:05 AMPPASS
BLD19-01704 BLD-Energy code compliance8/6/20198/8/20198/8/2019 11:17:42 AMAPASS
Vinnie Phone #: ###-####
BLD19-02911 BLD-Footing8/6/20198/8/20198/8/2019 10:58:35 AMAPASS
Phone #: ###-#### Inspection requested via web by anel duratovic
BLD19-00820 BLD-Wall Bracing8/7/20198/8/20198/8/2019 10:37:17 AMAPART
Mark Phone #: ###-####//add shear blocking and nail at blocks//discussed onsite//will check at framing//
MIS19-00229 BLD-Conference8/2/20198/8/20198/8/2019 10:00:57 AMADONE
follow up//permit was obtained for roof//
MIS19-00229 DOC - Permit Finaled8/8/20198/8/20198/8/2019 10:00:39 AMPPASS
BLD18-01162 BLD-Final8/7/20198/8/20198/8/2019 9:57:59 AMAPASS
Steven Phone #: ###-####//platforms added under egress windows for code compliance//bedroom that is not code compliant is boarded up--not readily accessible and will require sufficient effort to access//bonus room addition is boarded up and not readily accessible--and will require significant effort to access//plan modification will need to be provided and approved to use space that is boarded off//these areas will need inspection prior to approved use//
BLD18-01162 DOC - Permit Finaled8/8/20198/8/20198/8/2019 9:52:44 AMPPASS
BLD19-01678 BLD-Wall Bracing8/7/20198/8/20198/8/2019 9:21:37 AMAPASS
Danny Phone #: ###-####//nailing on exterior walls only//check holddowns on portal frame at framing///
BLD19-02226 BLD-Energy code compliance8/7/20198/8/20198/8/2019 8:56:08 AMAPASS
Tim Phone #: ###-####
BLD19-01808 BLD-Final8/8/20198/8/20198/8/2019 8:31:44 AMPCANC
They are seal-coating the parking lot today, call me when you are on your way and I''ll save a parking spot for you on Northview. Thanks Phone #: ###-#### >> Inspection requested via web by Mike Walling Inspection cancelled from web by: Mike Walling
MIS19-00230 BLD-Conference8/2/20198/8/20198/8/2019 8:14:35 AMADONE
follow up//permit has been issued//
MIS18-00388 MIS-Aging Inspection8/8/20198/8/20198/8/2019 8:14:35 AM PASS
MIS19-00230 DOC - Permit Finaled8/8/20198/8/20198/8/2019 8:14:14 AMPPASS