Inspections for the day of: Tuesday, September 10, 2019.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS18-00130 MIS-Aging Inspection9/10/20199/10/20199/13/2019 8:06:43 AM PASS
BLD18-03176 BLD-Aging Inspection9/10/20199/10/20199/11/2019 9:49:46 AM PASS
Expires: 10/26/19
BLD18-03921 BLD-Aging Inspection9/10/20199/10/20199/11/2019 9:49:05 AM PASS

Expires: 10/26/19
BLD18-03122 BLD-Energy code compliance9/10/20199/10/20199/10/2019 3:41:52 PMPPASS
mATT Phone #: ###-####//last six units//101,102,201,202,301,303//ok to cover//
BLD18-04585 BLD-Final9/10/20199/10/20199/10/2019 3:27:43 PMPNR
Call Dan for access Phone #: ###-#### Inspection requested via web by Daniel Appel//need final on fireplace// spoke with contractor he will call in re-inspection//
BLD18-03822 BLD-Blower Door Test Results9/10/20199/10/20199/10/2019 3:02:19 PMPDONE
4.27 ACH 50
1390 cfm @ 50 pa
BLD18-03822 BLD-Final9/9/20199/10/20199/10/2019 3:00:59 PMPPASS
Vince Phone #: ###-####
BLD18-03822 DOC - Permit Finaled9/10/20199/10/20199/10/2019 3:00:49 PMPPASS
BLD18-03863 BLD-Blower Door Test Results9/10/20199/10/20199/10/2019 3:00:33 PMPDONE
4.25 ACH 50
1386 cfm @ 50 pa
BLD18-03863 BLD-Final9/9/20199/10/20199/10/2019 2:58:52 PMPPASS
Vince Phone #: ###-####
BLD18-03863 DOC - Permit Finaled9/10/20199/10/20199/10/2019 2:58:42 PMPPASS
BLD19-02377 BLD-Framing/Rough-in9/10/20199/10/20199/10/2019 2:24:35 PMPPASS
Phone #: ###-#### Inspection requested via web by Kelly Stover
BLD19-01653 BLD-Framing/Rough-in9/10/20199/10/20199/10/2019 1:03:34 PMPFAIL
Wes Phone #: ###-####//need to provide approved plans onsite for all inspections//call for re-inspection when plans are onsite//
BLD19-01852 BLD-Framing/Rough-in9/9/20199/10/20199/10/2019 12:34:34 PMPPART
Craig Phone #: 208-407-808//most corrections made//need to fire block at stair platforns//add re-inforcement to joists per engineering//ok to insulate only//
BLD19-03270 BLD-Final9/9/20199/10/20199/10/2019 12:00:00 PMPPASS
Pls contact Brad (Foreman) @ ###-#### or Preston (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes//racking installed//electrical final complete//no structural changes//
BLD19-03270 DOC - Permit Finaled9/10/20199/10/20199/10/2019 11:59:43 AMPPASS
BLD19-01878 BLD-Conference9/10/20199/10/20199/10/2019 11:03:10 AMADONE
Phone #: ###-#### Inspection requested via web by Greg Stahl//framing questions//
BLD18-01759 BLD-Conference9/9/20199/10/20199/10/2019 11:02:41 AMADONE
Jim( husband)-would like a call prior to meet Phone #: ###-####//discussed handrails and guards at stairway//
BLD19-03376 BLD-Framing/Rough-in9/9/20199/10/20199/10/2019 9:52:37 AMANR
Michael Phone #: ###-####//need electrical, mechanical and plumbing rough passed prior to inspection for framing//
BLD19-02600 BLD-Wall Bracing9/9/20199/10/20199/10/2019 9:45:45 AMAPART
Phone #: ###-#### Inspection requested via web by Kelly Stover//nailing on exterior ok only// check bolts and straps at framing//
MIS18-00442 MIS-Aging Inspection9/10/20199/10/20199/10/2019 9:44:56 AM DONE
no activity
MIS18-00442 DOC - Permit Finaled9/10/20199/10/20199/10/2019 9:44:31 AMPPASS
BLD19-00820 BLD-Framing/Rough-in9/9/20199/10/20199/10/2019 9:16:25 AMAPASS
Mark Phone #: ###-####//ok per plans// ok to insulate only//