Inspections for the day of: Thursday, January 12, 2017.
Number of inspections: 17
Percentage of inspections complete: 71 %
Percentage of inspections not complete: 29 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-00406 General Inspection1/5/20171/9/2017 P 
check for snowmelt issues
ESC15-00853 General Inspection1/10/20171/10/2017   
ESC15-00731 General Inspection1/12/20171/12/20171/17/2017 8:14:17 AM CANC
ESC16-00849 General Inspection1/12/20171/12/20171/17/2017 8:14:07 AM CANC
ESC16-00712 General Inspection1/12/20171/12/20171/17/2017 8:12:01 AM CANC
ESC16-00499 General Inspection1/12/20171/12/20171/17/2017 8:11:52 AM CANC
ESC16-00208 General Inspection1/12/20171/12/20171/17/2017 8:11:33 AM CANC
ESC16-00838 General Inspection1/12/20171/12/20171/13/2017 8:26:13 AM CANC
ESC16-00805 Aging Inspection1/12/20171/12/20171/13/2017 8:07:49 AM CANC
ESC16-00665 Aging Inspection1/12/20171/12/20171/13/2017 8:07:41 AM CANC
ESC16-00664 Aging Inspection1/12/20171/12/20171/13/2017 8:07:32 AM CANC
ESC15-00729 Conference1/11/20171/12/20171/12/2017 2:13:46 PMAPEND
Notified RP of inspection observations from 1/11. Discussed the following:

- next to the access road from Council Springs Rd., treated runoff water discharged from stormwater pond is eroding a channel outside of the rip rap lined channel and picking up sediment and removing soil from site. This water flows to Council Springs Creek. RP stated he was aware of issue, but no actions have been taken. Additional sediment controls & corrective efforts to route the water to correct channel should be implemented as weather conditions allow.

- water running through the drainage channel to west of Barber Drive is flowing around check dams, flowing through & under check dams, no pooling of water, and no channel stabilizing erosion controls were installed or vegetation established. The check dams may not have been designed for the high runoff volume and velocity occuring and will need repair and re-design. Water passing through this area is retained in the onsite stormwater ponds.

Conditions are not ideal for immediate corrective actions due to below freezing temperatures, and unstabile & water logged ground, however having identified these problems the issues should be addressed
ESC15-01441 Aging Inspection1/12/20171/12/20171/12/2017 8:27:31 AM CANC
ESC16-00754 Aging Inspection1/12/20171/12/20171/12/2017 8:27:15 AM CANC
ESC16-00841 General Inspection1/12/20171/12/2017   
ESC16-00853 General Inspection1/12/20171/12/2017   
ESC16-01253 BMP Violation1/11/20171/12/2017 A