PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Wednesday, January 2, 2019
.
Number of inspections:
24
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC17-01414
General Inspection
1/2/2019
1/2/2019
1/7/2019 4:29:42 PM
CANC
ESC15-00556
General Inspection
1/2/2019
1/2/2019
1/7/2019 4:27:50 PM
CANC
ESC18-01438
General Inspection
12/28/2018
1/2/2019
1/4/2019 10:12:13 AM
P
FAIL
corrections not complete. No new violations.
2nd request to RP Joel to complete corrections by Thursday 1/10 PM
ESC18-01651
General Inspection
12/28/2018
1/2/2019
1/4/2019 10:11:38 AM
P
FAIL
corrections not complete. No new violations.
2nd request to RP Joel to complete corrections by Thursday 1/10 PM
ESC17-01386
General Inspection
12/28/2018
1/2/2019
1/4/2019 10:04:17 AM
P
CANC
rescheduled for site final
ESC17-01479
General Inspection
1/2/2019
1/2/2019
1/4/2019 10:03:31 AM
CANC
rescheduled
MIS18-00472
ESC-Conference
12/28/2018
1/2/2019
1/3/2019 4:54:17 PM
A
PEND
No new activity where open parcel was accessed off Winter Camp by excavator machine.
Jenkins Erosion Control has installed a perimeter sediment control wattle properly, and material for erosion control blankets has been placed on a disturbed slope but does require further work for proper installation (stakes unable to be hammered in due to frozen ground, key trench at top of blanket, and shingle blankets down the slope). ESC contact Jill shall be notified of the corrections needed.
Notice was given to not do any placement of gravel or other material on this parcel until further notice or approval.
No further corrections requested at this time. Case is still under investigation for full resolution.
ESC17-01455
Aging Inspection
1/2/2019
1/2/2019
1/3/2019 3:24:47 PM
PASS
ESC18-01285
General Inspection
12/28/2018
1/2/2019
1/3/2019 3:04:51 PM
A
FAIL
check on entrance
Corrections needed:
Entrance is compacted and will not work when muddy conditions return
Correction requests:
- scrape compacted rock to loosen hardened dirt.
- add additional angular rock to entrance to add edges to scape tires. Check construction details in ESC plan for specs.
- sweep sidewalk and gutter along Raymond Street next to project.
Written Correction notice posted with CM Company Darrel G.
Compliance is due Monday Jan 7 @12 PM
ESC14-01063
General Inspection
1/2/2019
1/2/2019
1/3/2019 1:15:19 PM
PART
3 SFHs in progress on Eyrie Way. Perimeter sediment control wattles and slope interuption wattles on hillsides are installed properly. No discharges or sediment runoff observed.
Lined concrete washout is installed at Arrow Villa and Winter Camp.
Correction request for next inspection (2 weeks)
- pick up and remove discarded BMPs and materials laying around on the parcel on Arrow Villa across from Goshawk, the former location of the concrete washout for phase 8 homes.
ESC17-01236
Aging Inspection
1/2/2019
1/2/2019
1/3/2019 1:11:05 PM
CANC
ESC18-01506
General Inspection
1/2/2019
1/2/2019
1/3/2019 10:20:10 AM
P
PART
Inspected 1/2 5 PM.
Concrete for garage poured. Washout used was near full. Most washout was able to be contained. Some spills around washout area and in close proximity to ditch are visible; ditch is currently dry
Correction request:
- wait for washout in container to dry, then dispose of. New washout containment will be needed for upcoming cement work.
Correction issued to RP/GC.
No other violations, trash contained. Storm drain on Rim has sediment protection.
ESC18-00158
Aging Inspection
1/2/2019
1/2/2019
1/2/2019 3:46:39 PM
CANC
rescheduled for site final
ESC18-00156
Aging Inspection
1/2/2019
1/2/2019
1/2/2019 3:44:04 PM
CANC
rescheduled for site final
ESC18-00488
Conference
1/2/2019
1/2/2019
1/2/2019 3:08:13 PM
P
DONE
phone call regarding submission of dewatering plan and updated SWPPP for project.
ESC18-00176
Conference
1/2/2019
1/2/2019
1/2/2019 1:00:00 PM
A
PASS
ESC onsite conference with RP Eric to review ESC BMPs
- double-lined wooden concrete washout box has been placed on site. Will relocate once pump truck arrives
- large rock stabilized access is installed.
- sandbag perimeter built around the storm drain for sediment protection.
- ESC permit sign is posted.
Approved for construction.
ESC17-01771
Conference
1/2/2019
1/2/2019
1/2/2019 12:44:34 PM
P
DONE
eric 2085591629
See ESC18-00176 for ESC permit coverage
ESC17-01771
DOC - Permit Finaled
1/2/2019
1/2/2019
1/2/2019 12:44:17 PM
P
PASS
ESC18-00246
Aging Inspection
1/2/2019
1/2/2019
1/2/2019 12:38:28 PM
PASS
ESC18-00246
DOC - Permit Finaled
1/2/2019
1/2/2019
1/2/2019 12:38:23 PM
P
PASS
ESC18-00939
BMP Violation
1/2/2019
1/2/2019
1/2/2019 12:29:23 PM
P
FAIL
Corrections needed:
- pick up all loose trash and put in trash container
- sweep sidewalk, gutter, and street in front of the two projects by Harding Homes.
Verbal corrections issued to RP-GC Gene. Note: Young Meadow onsite contact is Ron. Follow up scheduled 1/7
ESC17-00315
General Inspection
1/2/2019
1/2/2019
1/2/2019 8:21:04 AM
CANC
ESC16-00617
General Inspection
1/2/2019
1/2/2019
1/2/2019 8:12:32 AM
CANC
ESC18-00233
DOC - Permit Finaled
1/2/2019
1/2/2019
1/2/2019 8:09:22 AM
P
PASS