Inspections for the day of: Wednesday, January 30, 2019.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01497 BMP Violation1/29/20191/30/20192/1/2019 11:29:34 AMPFAIL
No corrections made. Pictures sent to RP. Stated he thought it was washout on Cassia.

Clean up is need on Hilton lots...
ESC16-00406 General Inspection1/30/20191/30/20191/30/2019 5:00:57 PMPFAIL
Corrections needed:

- fix erosion and sediment runoff occuring on Sandpoint (lot 9, block 2). Previous inspeciton notes on 12/11 incorrect, no repair of rill/channel. Need to install additional wattles to slow flow of water and retain on lots rather than flowing down cut slopes.
- fix erosion off Broadstone on common area leading to golf course.
- pick up loose trash in common areas.
ESC18-01687 General Inspection1/30/20191/30/20191/30/2019 4:34:47 PMPPASS
WIP on grading and excavation within the Ft. Boise basin area. No offhaul yet, no additional construction entrance installed yet. No sediment runoff or trackout observed. Job site and worker parking area has been kept clean.
ESC18-00462 General Inspection1/30/20191/30/20191/30/2019 3:15:46 PM PASS
ESC18-00440 General Inspection1/30/20191/30/20191/30/2019 3:14:29 PM PEND
homeowner continued site work after pool contractor left. Will continue to monitor. Lot may soon be new SFH.
ESC18-00498 General Inspection1/30/20191/30/20191/30/2019 3:00:50 PMPPASS
Hillside erosion controls in place. Some grasses are starting to grow. No significant rills or sediment runoff observed. Subdivision storm drains have sediment protection. RP on site. No corrections.
ESC17-01113 DOC - Permit Finaled1/30/20191/30/20191/30/2019 2:50:03 PMPPASS
ESC17-01113 DOC - Permit Finaled1/30/20191/30/20191/30/2019 2:49:07 PMPPASS
ESC18-00984 Site Final1/30/20191/30/20191/30/2019 2:48:42 PMPPASS
BLD finaled. No disturbed area or loose dirt around site. ESC permit finaled.
ESC18-00844 General Inspection1/30/20191/30/20191/30/2019 2:47:51 PMPPASS
WIP. Permit posted, construction entrance installed. Perimeter vegetation preserved. Approved.
ESC18-01749 BMP Violation1/30/20191/30/20191/30/2019 2:21:48 PMPPASS
Water truck now onsite and in use for fugitive dust control as requested. Will continue to monitor.
ESC18-00946 General Inspection1/30/20191/30/20191/30/2019 1:45:54 PMPPEND
No new work or BMPs added since the first clean up and watttle placement.

still need to clean out dirt behind wattles and install additional controls on the upper section and stake in wattles.

RP should be back in town.
ESC18-01776 General Inspection1/30/20191/30/20191/30/2019 1:29:46 PMPPASS
Demo complete. No trackout. Site is below grade of road. Site is to become additional parking for the Jacksons. No corrections requested.
ESC17-01754 General Inspection1/30/20191/30/20191/30/2019 11:03:28 AMPFAIL
Correction request remaining:
- street sweepers need to focus on Federal Way SE bound between Targee and Latimer

Corrections competed:
- storm drain inlet sediment protection on Targee and SE Federal Way to Ralfroy have been installed
- pit run has been placed through site to limit mud from deliveries and workers
- worker parking has been rocked
- Hudson and Targee have been swept.

Correction request and inspection of Federal Way dirt conducted with RP JC. Sweep street tonight.