Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00396 BMP Violation1/30/20201/30/20201/31/2020 4:35:39 PMPFAIL
follow up inspection

Trash bin has been emptied. Still a garbage can worth of trash stuck in around the perimeter fencing and around patio area and next to the bin. Site is still not in compliance.


Violations:
- unmaintained/muddy construciton entrance site access
- minor trackout ; dirty sidewalk & gutter
- damanged and improperly installed silt fence
- uncontained trash around site.


Corrections needed at site:

- Install construction entrance
- fix wall of trash container that has been removed
- sweep sidewalk and gutter along Silver Crest
- fix/re-install silt fence or other perimeter sediment control on the downslope side of the site entrance and at the bottom corner of site where temporary power pole is.
- post ESC permit sign
- provide tub for paint and wall board washout/rinsing activities

Schedule site inspection and pay fines issued. GC should consider taking the RP class.
ESC19-00292 General Inspection1/28/20201/30/20201/31/2020 3:43:47 PMPPEND
follow up
ESC16-01457 General Inspection1/30/20201/30/20201/31/2020 2:35:42 PM CANC
ESC19-00541 General Inspection1/30/20201/30/20201/31/2020 2:34:11 PM CANC
ESC19-00409 Aging Inspection1/30/20201/30/20201/31/2020 12:08:19 PM CANC
ESC18-01674 General Inspection1/30/20201/30/20201/31/2020 11:33:27 AM CANC
rescheduled
ESC18-01789 Aging Inspection1/30/20201/30/20201/30/2020 4:24:10 PM CANC
ESC18-01444 General Inspection1/30/20201/30/20201/30/2020 4:20:50 PM CANC
rescheduled
ESC19-00406 Aging Inspection1/30/20201/30/20201/30/2020 4:20:23 PM CANC
ESC19-00406 DOC - Permit Finaled1/30/20201/30/20201/30/2020 4:20:19 PMPPASS