Inspections for the day of: Tuesday, January 8, 2019.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01739 Tracking Control1/8/20191/8/20191/11/2019 3:06:12 PMPPEND
need to send letter of notice to all builders in Bonneville Point.
ESC18-01329 BMP Violation1/4/20191/8/20191/11/2019 2:56:49 PMPCANC
ESC18-00020 General Inspection1/8/20191/8/20191/8/2019 3:53:11 PMPFAIL

Corrections needed:

- construction entrance at upper staging and stockpile area and the concrete washout on Hootowl needs more construction rock and to turn up the existing rock compacted with mud. There is trackout at both areas.

Install new rock, make sure there is adequate length, width, depth and type of rock per SWPPP construction details for construction entrances.

Schedule follow up inspection.

ESC16-00489 General Inspection1/7/20191/8/20191/8/2019 3:19:07 PMPPASS
SFHs in progress. Subdivision near full. Need to have WR Gann and Seidl homes pull the DI bags that are still installed where all parcels are stabilized.
ESC18-01626 General Inspection1/8/20191/8/20191/8/2019 3:18:07 PMPPASS
Concrete washout containement utilized. Permit signs posted. No trackout or discharges.
ESC18-00005 Site Final1/8/20191/8/20191/8/2019 3:15:56 PMPPASS
Home complete and landscaped. Storm drain sediment protection installed for ongoing construction in DHE #15-16
ESC18-00355 Site Final1/8/20191/8/20191/8/2019 3:15:00 PMPPASS
Home complete and landscaped. Storm drain sediment protection installed for ongoing construction in DHE #15-16
ESC17-00013 General Inspection1/8/20191/8/20191/8/2019 3:12:40 PMPPASS
Homes now in progress and permitted seperately. Contractor is Walt Gann. Lined concrete washout provided, permit signs posted. No trackout or discharges. No trash issues.
ESC17-01680 Aging Inspection1/8/20191/8/20191/8/2019 3:00:00 PM PASS
ESC18-01568 Complaint Inspection1/8/20191/8/20191/8/2019 2:57:02 PMPPEND
No permit sign posted. Some mud and debris from site on sidewalk and gutter in front of home.

Posted ESC permit sign.

Corrections needed:
- pick up loose trash just outside of trash bin
- sweep sidewalk regularly; install boards or gravel for workers to walk on to prevent muddying trackout.
- do not park on grassy median between curb and sidewalk to preserve the vegetation
ESC18-01534 Site Final1/8/20191/8/20191/8/2019 2:42:52 PMPDONE
See ESC18-01534 for rest of project
ESC17-01687 BMP Violation1/8/20191/8/20191/8/2019 2:08:40 PMPFAIL
Corrections needed:
- pick up all loose trash around site
- get a dumpster or trash container built
- maintain construciton entrances. Close gate for River Street access.

Follow up Friday 1/11
ESC16-01706 General Inspection1/8/20191/8/20191/8/2019 12:22:54 PM PASS
Warehouse now complete. Parking lot paved and frontage along Irving has been sodded. Large stockpile of dirt and disturbed area are still onsite. Will continue to monitor. No trackout or discharges occuring.
ESC18-01289 General Inspection1/7/20191/8/20191/8/2019 12:04:53 PMPPASS
No trackout to Federal Way or Summersweet. Construction entrances and storm drains sediment protection are installed.
ESC17-01360 General Inspection1/8/20191/8/20191/8/2019 11:49:13 AMPFAIL
Corrections needed:

- concrete washout area needs new construction rock entrance and/or maintenance of existing entrance to prevent further trackout. Some minor trackout already occuring.
- one container is full to brim, spilling over. A new containment is needed. The other bin does not have a ramp(?)
- need to work with SFH homebuilders to do a trash pick up in the open areas. Lots of wind blown trash and debris in all open spaces between homes.



No trackout or discharges offsite. Stormdrains have sediment protection.
ESC18-01071 General Inspection1/8/20191/8/20191/8/2019 11:38:41 AMPPASS
No activity at time of inspection. Roads have been cut and sewer installed. Need to get paving, curb, and sidewalks. No trackout from site, no loose trash. Permit and SWPPP info posted at end of Snow Bird.
ESC18-01253 General Inspection1/8/20191/8/20191/8/2019 11:15:49 AMPPASS
Temporary parking lot complete, compacted road mix surface. Will keep permit open to monitor runoff . Sheeet flow to surrounding vegetation.

Lots of trash dumped in the area.
ESC18-01411 General Inspection1/8/20191/8/20191/8/2019 10:34:38 AMAPASS
Permit sign posted. Storm drain on McGregor has and sediment protection. No activity at site, grading for building footprint looks complete.

No significant trackout, but once work resumes the construction entrance will need to scraped and more rock added.
ESC16-00938 General Inspection1/8/20191/8/20191/8/2019 8:17:09 AM CANC
ESC17-01762 General Inspection1/8/20191/8/20191/8/2019 8:15:04 AM FAIL
Ongoing trackout issues. See ESC17-01754 for inspection reports and enforcement
ESC17-01761 General Inspection1/8/20191/8/20191/8/2019 8:14:39 AM FAIL
Ongoing trackout issues. See ESC17-01754 for inspection reports and enforcement
ESC17-01760 General Inspection1/8/20191/8/20191/8/2019 8:14:22 AM FAIL
Ongoing trackout issues. See ESC17-01754 for inspection reports and enforcement
ESC17-01759 General Inspection1/8/20191/8/20191/8/2019 8:13:57 AM FAIL
Ongoing trackout issues. See ESC17-01754 for inspection reports and enforcement
ESC17-01758 General Inspection1/8/20191/8/20191/8/2019 8:13:38 AM FAIL
Ongoing trackout issues. See ESC17-01754 for inspection reports and enforcement