ESC12-00403
| Site Final | 10/1/2018 | 10/1/2018 | 10/5/2018 4:31:09 PM | P | CANC |
|
|
|
ESC18-00983
| General Inspection | 9/28/2018 | 10/1/2018 | 10/3/2018 10:24:00 AM | A | PASS |
|
|
Majority of mass grading is complete. Berms and ditches to be installed on top of ridge to divert water away from slopes. Slopes have had topsoil spread and horizontally tracked.
Next week installation of wattles is to begin. Wattles to be installed every 25 vertical feet on slopes. Will use heavy duty bark wattles. Wattles MUST be trenched in 2-3 inches, staked every4-5 ft, and have overlapping ends. Inspection scheduled to check on installation next week. After wattles are installed, hydroseeding will be completed on all disturbed areas to be inactive for stabilization. Should be near the end of October. Pipe work will begin in November for sewer & water. Request to beef up construction entrance at that time to prevent trackout. Large stockpiles at top and bottom of site must be tacified once fully inactive. RP to review stabilization requirements of 2.2 in CGP 2017.
No trackout, wind blown dust, loose trash, or discharges observed. Follow up scheduled.
|
ESC15-01091
| General Inspection | 10/1/2018 | 10/1/2018 | 10/2/2018 4:05:11 PM | | PASS |
|
|
|
ESC17-00793
| General Inspection | 9/28/2018 | 10/1/2018 | 10/2/2018 3:40:25 PM | P | PART |
|
|
No significant trackout. Topsoil being placed for landscaping. Storm drain has inlet protection and gravel bag sediment checks in gutter between home and storm drain.
Correction: - sweep sidewalk - remove pile of trash and BMPs at bottom of site.
|
ESC16-00741
| General Inspection | 9/27/2018 | 10/1/2018 | 10/2/2018 2:12:39 PM | P | FAIL |
|
|
check for new inlet protection at 5th & Main.
No new inlet protection. No wet weather or other violations. Compliance extended till end of day tomorrow PM.
|
ESC16-01342
| Aging Inspection | 10/1/2018 | 10/1/2018 | 10/2/2018 12:56:24 PM | | PASS |
|
|
No new activity. No ESC corrections needed at this time.
|
ESC16-00489
| General Inspection | 10/1/2018 | 10/1/2018 | 10/2/2018 12:13:35 PM | | PASS |
|
|
WIP on SFHS, several lots still vacant. Storm drains have sediment filter bags installed. No trackout or discharges observed in subdivision area. No corrections.
|
ESC18-01229
| Conference | 9/28/2018 | 10/1/2018 | 10/2/2018 8:24:11 AM | A | PEND |
|
|
check on ROS and site work without permit
|
ESC15-01579
| General Inspection | 10/1/2018 | 10/1/2018 | 10/1/2018 3:41:39 PM | | CANC |
|
|
|
ESC17-00971
| General Inspection | 9/28/2018 | 10/1/2018 | 10/1/2018 3:32:55 PM | A | FAIL |
|
|
Inactive stockpiles area still on site. No perimeter protect. Streets and infrastructure are complete. Storm drains have sediment bags installed.
Will schedule compliance conference with RP and developer.
|
ESC17-01470
| General Inspection | 10/1/2018 | 10/1/2018 | 10/1/2018 3:27:06 PM | P | FAIL |
|
|
Track out and loose dirt on Sunrise Manor. Site needs sweeping around perimeter and on the street.
|
ESC18-00689
| Site Final | 10/1/2018 | 10/1/2018 | 10/1/2018 3:22:52 PM | P | PASS |
|
|
Trash enclosures are complete. No disturbed area or loose material in project area. ESC permit finaled.
|
ESC17-01172
| Site Final | 10/1/2018 | 10/1/2018 | 10/1/2018 3:19:55 PM | P | NR |
|
|
Temporary BMP storm drain bags left installed. Project is stabilized, building is complete and open for businees.
Correction request to RP Darrell remove DI bag on Steelwood and Gabrielle.
|
ESC17-01200
| Conference | 9/28/2018 | 10/1/2018 | 10/1/2018 3:09:02 PM | P | CANC |
|
|
data entry error
|
ESC17-00470
| General Inspection | 10/1/2018 | 10/1/2018 | 10/1/2018 3:08:33 PM | P | PASS |
|
|
Home on NW corner of development has still not been moved. No new construction activity. No trackout or discahrges from bare lots. No corrections requested. Will continue to monitor.
|
ESC18-00659
| General Inspection | 9/27/2018 | 10/1/2018 | 10/1/2018 2:45:20 PM | P | PART |
|
|
No trackout from site. No windblown dust.
Corrections needed for next phase.
- Stabilize any stockpiles that are to remain inactive. -Install heavy duty construction entrance, current one is no designated, has no lining and is not long or wide enough. - protect storm drains on Dawn with sediment bag or filter mat.
|
ESC18-00946
| BMP Violation | 9/28/2018 | 10/1/2018 | 10/1/2018 2:31:05 PM | A | PEND |
|
|
RP-GC was out of town last week.
Request to sweep road shoulder and gutter and to stake in wattles today. Conference scheduled for Wednesday
|
ESC18-01394
| Site Preparation | 10/1/2018 | 10/1/2018 | 10/1/2018 1:28:46 PM | A | PASS |
|
|
WIP on commercial demolition. Water is being used to supress construction dust. Debris being immediately loaded into large trailer. No trackout or discharges. Approved. Once demolition is complete, parking lot will be covered under ESC18-01145.
|
ESC18-00529
| General Inspection | 10/1/2018 | 10/1/2018 | 10/1/2018 12:51:07 PM | P | PASS |
|
|
WIP on vertical. No trackout or dicharges from site or staging area across the street. Trash and materials are contained.
|
ESC16-00242
| General Inspection | 10/1/2018 | 10/1/2018 | 10/1/2018 10:01:20 AM | | CANC |
|
|
Walk through of all ESC permits at Micron to be conducted this month.
|