Inspections for the day of: Tuesday, October 18, 2016.
Number of inspections: 29
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC14-00588 General Inspection10/18/201610/18/201610/20/2016 9:56:21 AM PASS
WIP on site improvement and units on the south west side of site. Main entrance is paved; newly installed swale along Parkcenter has been sodded and curb cut inlets cleaned. Minor trackout to road apron at the auxiliarry construction exit, no muddy trackout.

WIP. No corrections at this time
ESC16-00088 General Inspection10/18/201610/18/201610/19/2016 4:29:00 PM CANC
ESC15-00468 General Inspection10/18/201610/18/201610/19/2016 4:28:55 PM CANC
ESC16-00905 Site Preparation10/11/201610/18/201610/19/2016 12:42:18 PMPCANC
data entry error, not site prep
ESC16-00059 Site Preparation10/17/201610/18/201610/18/2016 4:51:20 PMAPASS
Clint Phone #: ###-####

Belmar subdivision BMPs installed. Approved.
ESC16-00871 DOC - Permit Finaled10/18/201610/18/201610/18/2016 4:49:35 PMPPASS
(This activity was added in error so we have changed the case status back to Issued.)
ESC16-00774 Tracking Control10/18/201610/18/201610/18/2016 4:30:34 PMPFAIL
Trackout from site extending to Golden Rod from site. No stabilized entrance or access prevention to long muddy driveway. No permit sign clearly posted at time of inspection.

Correction request to provide construction entrance or stabilized parking area; and/or no parking signs and cleanup to prevent trackout.
ESC16-01387 Site Preparation10/18/201610/18/201610/18/2016 4:16:48 PMPPASS
Charlie-please call with a meet time Phone #: ###-####

Permit sign posted. Reviewed ESC condtions with builder. No MS4 system in area. Irrigation ditch has no water (shut off). Approved for construction.
ESC16-00264 Site Preparation10/17/201610/18/201610/18/2016 4:00:59 PMACANC
Clint Phone #: ###-####

rescheduled for inspection 10/19. Ok to start, East Valley BMPs installed.
ESC16-00110 Aging Inspection10/18/201610/18/201610/18/2016 4:00:11 PM CANC
ESC16-00111 Aging Inspection10/18/201610/18/201610/18/2016 4:00:06 PM CANC
ESC15-01171 General Inspection10/18/201610/18/201610/18/2016 3:38:37 PMPPASS

Subdivision inlets protected with filter mats, perimeter wattles on some of the open lot. SFH construction in progress, permitted seperately and with corrections.
ESC15-01244 Aging Inspection10/18/201610/18/201610/18/2016 2:37:16 PM PASS
ESC15-01060 General Inspection10/18/201610/18/201610/18/2016 2:19:30 PM CANC
ESC16-00137 Aging Inspection10/18/201610/18/201610/18/2016 2:14:42 PM PASS
Work on occuring on the interior and materials on site stored in trailers. No muddy runoff, trackout, or other issues observed.
ESC16-00353 Random Inspection10/18/201610/18/201610/18/2016 1:59:46 PMPPASS
No issues observed due to rainfall on recently developed foothills sub. BMPs installed and preveting muddy runoff. No corrections requested.
ESC15-01308 Complaint Inspection10/18/201610/18/201610/18/2016 1:51:52 PMPDONE
No ESC related issue regarding retaining wall. Wall is a landscape wall to provide flat area for patio.

Wall listed on site plans and indicated to be under 4 feet requirement for engineered wall. No turbid runoff from site at time of inspection, DIs have sediment filter bags installed.

No damage or mud observed on occupied neighbors backyard.
ESC16-01184 General Inspection10/18/201610/18/201610/18/2016 1:28:44 PMPPASS
Restoration/repair work is complete. Sediment and erosion controls installed on hillside to stabilze include two silt fences, erosion control blanket, and wattles. Does not look like the hillside has any vegetation coming in under blanket at this time.
ESC15-01420 General Inspection10/18/201610/18/201610/18/2016 1:16:45 PM CANC
ESC16-00561 General Inspection10/18/201610/18/201610/18/2016 1:16:27 PMAPASS
No activity at time of inspeciton. No muddy runoff coming from site. Perimeter sediment control wattles are installed properly and no trackout.

RP/GC installed silt along back side of home below a disturbed slope area as requested. No violations, corrections requested in previous inspections have been addressed. N
ESC16-00225 General Inspection10/18/201610/18/201610/18/2016 10:17:13 AMAPART
hillside development rainfall inspection.

Entrance at Windsong and Galactic in good condition. Runoff for upper site is retained on site and BMPs installed at outlet.

Only muddy runoff source is at the east Trent Point entrance. Disturbed area from concrete washout installation, muddy equipment, and some trackout causing turbid discharge. Downstream inlet at bottom of hill does not have filter bag or mat due to location at low point and private driveway access & flooding issues.

Verbal correction to RP to clean up entrance better, install wattles on upper side of street and clean out accumulated materials in check dams.



RP on site and will work on clean up and installing perimeter controls around washout to prepare/ make corrective actions for next rainfall.
ESC15-01138 General Inspection10/18/201610/18/201610/18/2016 9:47:20 AM PEND
ESC16-00090 Aging Inspection10/18/201610/18/201610/18/2016 9:19:01 AM PASS
ESC14-00928 General Inspection10/18/201610/18/201610/18/2016 9:04:25 AMPPASS
MS4 on 11th and Grove has filter bag installed and is draining and filtering. Runoff down Grove from site is not muddy or discolored. No corrections isssued
ESC15-01483 General Inspection10/18/201610/18/201610/18/2016 8:56:16 AM PASS
Vertical construction on exterior and work on the interior is in progress. Unpaved parking and access area is below grade of edge of pavement for curbs, no muddy runoff. MS4 filter bags installed on Bannack at 10th and 11th, no trackout to 11th from construction entrance. Approved.
ESC16-00189 General Inspection10/18/201610/18/201610/18/2016 7:55:47 AM CANC
Gatewood duplexes inspected 10/17, no inspection today. foundations in progress. No corrections at this time
ESC16-00133 General Inspection10/18/201610/18/201610/18/2016 7:52:45 AM CANC
project already finaled
ESC16-00133 DOC - Permit Finaled10/18/201610/18/201610/18/2016 7:52:34 AMPPASS
ESC15-00871 General Inspection10/14/201610/18/201610/17/2016 1:14:37 PMAPASS