ESC14-00588
| General Inspection | 10/18/2016 | 10/18/2016 | 10/20/2016 9:56:21 AM | | PASS |
|
|
WIP on site improvement and units on the south west side of site. Main entrance is paved; newly installed swale along Parkcenter has been sodded and curb cut inlets cleaned. Minor trackout to road apron at the auxiliarry construction exit, no muddy trackout.
WIP. No corrections at this time
|
ESC16-00088
| General Inspection | 10/18/2016 | 10/18/2016 | 10/19/2016 4:29:00 PM | | CANC |
|
|
|
ESC15-00468
| General Inspection | 10/18/2016 | 10/18/2016 | 10/19/2016 4:28:55 PM | | CANC |
|
|
|
ESC16-00905
| Site Preparation | 10/11/2016 | 10/18/2016 | 10/19/2016 12:42:18 PM | P | CANC |
|
|
data entry error, not site prep
|
ESC16-00059
| Site Preparation | 10/17/2016 | 10/18/2016 | 10/18/2016 4:51:20 PM | A | PASS |
|
|
Clint Phone #: ###-####
Belmar subdivision BMPs installed. Approved.
|
ESC16-00871
| DOC - Permit Finaled | 10/18/2016 | 10/18/2016 | 10/18/2016 4:49:35 PM | P | PASS |
|
|
(This activity was added in error so we have changed the case status back to Issued.)
|
ESC16-00774
| Tracking Control | 10/18/2016 | 10/18/2016 | 10/18/2016 4:30:34 PM | P | FAIL |
|
|
Trackout from site extending to Golden Rod from site. No stabilized entrance or access prevention to long muddy driveway. No permit sign clearly posted at time of inspection.
Correction request to provide construction entrance or stabilized parking area; and/or no parking signs and cleanup to prevent trackout.
|
ESC16-01387
| Site Preparation | 10/18/2016 | 10/18/2016 | 10/18/2016 4:16:48 PM | P | PASS |
|
|
Charlie-please call with a meet time Phone #: ###-####
Permit sign posted. Reviewed ESC condtions with builder. No MS4 system in area. Irrigation ditch has no water (shut off). Approved for construction.
|
ESC16-00264
| Site Preparation | 10/17/2016 | 10/18/2016 | 10/18/2016 4:00:59 PM | A | CANC |
|
|
Clint Phone #: ###-####
rescheduled for inspection 10/19. Ok to start, East Valley BMPs installed.
|
ESC16-00110
| Aging Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 4:00:11 PM | | CANC |
|
|
|
ESC16-00111
| Aging Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 4:00:06 PM | | CANC |
|
|
|
ESC15-01171
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 3:38:37 PM | P | PASS |
|
|
Subdivision inlets protected with filter mats, perimeter wattles on some of the open lot. SFH construction in progress, permitted seperately and with corrections.
|
ESC15-01244
| Aging Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 2:37:16 PM | | PASS |
|
|
|
ESC15-01060
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 2:19:30 PM | | CANC |
|
|
|
ESC16-00137
| Aging Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 2:14:42 PM | | PASS |
|
|
Work on occuring on the interior and materials on site stored in trailers. No muddy runoff, trackout, or other issues observed.
|
ESC16-00353
| Random Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 1:59:46 PM | P | PASS |
|
|
No issues observed due to rainfall on recently developed foothills sub. BMPs installed and preveting muddy runoff. No corrections requested.
|
ESC15-01308
| Complaint Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 1:51:52 PM | P | DONE |
|
|
No ESC related issue regarding retaining wall. Wall is a landscape wall to provide flat area for patio.
Wall listed on site plans and indicated to be under 4 feet requirement for engineered wall. No turbid runoff from site at time of inspection, DIs have sediment filter bags installed.
No damage or mud observed on occupied neighbors backyard.
|
ESC16-01184
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 1:28:44 PM | P | PASS |
|
|
Restoration/repair work is complete. Sediment and erosion controls installed on hillside to stabilze include two silt fences, erosion control blanket, and wattles. Does not look like the hillside has any vegetation coming in under blanket at this time.
|
ESC15-01420
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 1:16:45 PM | | CANC |
|
|
|
ESC16-00561
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 1:16:27 PM | A | PASS |
|
|
No activity at time of inspeciton. No muddy runoff coming from site. Perimeter sediment control wattles are installed properly and no trackout.
RP/GC installed silt along back side of home below a disturbed slope area as requested. No violations, corrections requested in previous inspections have been addressed. N
|
ESC16-00225
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 10:17:13 AM | A | PART |
|
|
hillside development rainfall inspection.
Entrance at Windsong and Galactic in good condition. Runoff for upper site is retained on site and BMPs installed at outlet.
Only muddy runoff source is at the east Trent Point entrance. Disturbed area from concrete washout installation, muddy equipment, and some trackout causing turbid discharge. Downstream inlet at bottom of hill does not have filter bag or mat due to location at low point and private driveway access & flooding issues.
Verbal correction to RP to clean up entrance better, install wattles on upper side of street and clean out accumulated materials in check dams.
RP on site and will work on clean up and installing perimeter controls around washout to prepare/ make corrective actions for next rainfall.
|
ESC15-01138
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 9:47:20 AM | | PEND |
|
|
|
ESC16-00090
| Aging Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 9:19:01 AM | | PASS |
|
|
|
ESC14-00928
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 9:04:25 AM | P | PASS |
|
|
MS4 on 11th and Grove has filter bag installed and is draining and filtering. Runoff down Grove from site is not muddy or discolored. No corrections isssued
|
ESC15-01483
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 8:56:16 AM | | PASS |
|
|
Vertical construction on exterior and work on the interior is in progress. Unpaved parking and access area is below grade of edge of pavement for curbs, no muddy runoff. MS4 filter bags installed on Bannack at 10th and 11th, no trackout to 11th from construction entrance. Approved.
|
ESC16-00189
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 7:55:47 AM | | CANC |
|
|
Gatewood duplexes inspected 10/17, no inspection today. foundations in progress. No corrections at this time
|
ESC16-00133
| General Inspection | 10/18/2016 | 10/18/2016 | 10/18/2016 7:52:45 AM | | CANC |
|
|
project already finaled
|
ESC16-00133
| DOC - Permit Finaled | 10/18/2016 | 10/18/2016 | 10/18/2016 7:52:34 AM | P | PASS |
|
|
|
ESC15-00871
| General Inspection | 10/14/2016 | 10/18/2016 | 10/17/2016 1:14:37 PM | A | PASS |
|
|
|