Inspections for the day of: Wednesday, October 21, 2015.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-00024 General Inspection10/21/201510/21/201510/22/2015 4:47:38 PM PASS
No activity at site. Driveway apron recently poured, no spills or residues in gutter observed. Trash and materials are contained and cleaned up, no trackout or loose sediment leaving site. Approved.
ESC15-01225 General Inspection10/21/201510/21/201510/21/2015 3:39:40 PMPPASS
WIP. Disturbed slopes have been tracked and are contained by sediment control wattles at perimeter. No trackout to Windsong or Draco. No corrections issued.
ESC15-00094 General Inspection10/21/201510/21/201510/21/2015 3:18:53 PM PASS
No sediment runoff from recent rainfall observed, or it has been cleaned. Hill slopes are currently free of significant erosion rills or gullys and wattle BMPs are installed and the hill was tracked/roughed to slow and contain runoff.

No corrections at this time, will investigate seperate home remodel contractor causing issues of Echo culdescac tomorrow AM.
ESC15-00729 Complaint Inspection10/21/201510/21/201510/21/2015 3:03:21 PMPPEND
Spill complaint investigation...

No evidence of spill or discharges of fuel or oil in and around the fuel storage area in the lower staging area. Some stormwater has collected in the secondary containment area but no sheen in the water was observed. Large fuel tank is double walled container and all barrels and used oil tank are located within a bermed containment area lined with vapor barrier. There is a spill kit located at this staging area.

Western Construction mobile service trucks fuel up at lower tank and then deliver to equipment either in upper laydown area or out in the field. Each unit is equipped with spill kit.

Western Construction GC stated he was not aware of spill other than note of leaking equipment noted by Syman Co. on their weekly SWPPP inspection logged 10/10.

SWPPP inspection notes:

10/10 Spills/equipment leaks reported at upper vehicle laydown area

10/20 Spill reported by inspector to have been cleaned up and no further issues at the upper laydown area

No offsite discharges, trackout to Barber Dr. or other issues observed during inspection. BMPS are installed and in good condition. Received update that slope stabilization and wattle installation should occur in approximately 2 weeks as Western finishes the initial grading.

Will continue to monitor situation and respond should other agencies inquire.
ESC14-00788 General Inspection10/21/201510/21/201510/21/2015 12:49:40 PMPPASS
Privada Estates retaining wall and some site work is currently in progress. Sweeping unit is onsite while they are finishing the entrance to the subdivision off Warm Springs. No discharges, fugitive dust. No corrections at this time. RP Lance is onsite monitoring work.
ESC15-00035 General Inspection10/21/201510/21/201510/21/2015 12:05:26 PM PASS
Antelope Springs SFHs in progress. No trackout from open lots, which are still muddy. Site has secure drainage perimeter and no discharges of runoff or other materials offsite. No corrections at this time.
ESC15-00405 Aging Inspection10/21/201510/21/201510/21/2015 11:03:48 AM PART
Sweep up on Signal Rock in progress. Construction is complete but streets are dirty. Currently in process of being cleaned. Will check back Friday for site final.
ESC15-00402 Aging Inspection10/21/201510/21/201510/21/2015 11:03:07 AM PART
Sweep up on Signal Rock in progress. Construction is complete but streets are dirty. Currently in process of being cleaned. Will check back Friday for site final.
ESC14-00657 Tracking Control10/21/201510/21/201510/21/2015 10:59:33 AMAPART
Trackout from active Brighton Homes projects has extended offsite to Warm Springs Road. Has not yet been cleaned since occuring on Monday. Dirt/mud clods on south shoulder of road should be removed

Brighton Homes crew in process of cleaning up streets with brooms and bobcat with sweeping attachment. May need to get a street sweeping truck on site...

Verbal notice issued to Brighton Homes and Brighton Co.
ESC15-00369 Aging Inspection10/21/201510/21/201510/21/2015 10:51:30 AM PASS
Home near completion. WIP on interior and is not yet landscaped. Trash contained, no sediment leaving home lot.

Sweeping and cleanup is in progress in RH #6 due to trackout from cement trucks along Signal Rock and some runoff during the weekend rain.
ESC15-01233 Site Preparation10/20/201510/21/201510/21/2015 9:50:49 AMAPASS
Adam Phone #: ###-####

Permit sign posted. BMPs implemented (DI bags sediment control, concrete washout, periodic street sweeping) . Approved.
ESC15-00501 Aging Inspection10/21/201510/21/201510/21/2015 8:56:55 AM PASS