Inspections for the day of: Tuesday, October 31, 2017.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00842 General Inspection10/31/201710/31/201711/2/2017 3:10:56 PMPPEND
NO construction entrance or onsite stormwater retention system in place. Site at considerable ESC risk.

More corrections and inspections scheduled. Inspected 11/1 by MPZ. No discharges or fugitive dust noted. Crews working on permanent stormwater pond/infiltration basin.
ESC12-00403 General Inspection10/31/201710/31/201711/1/2017 2:52:26 PM CANC
ESC17-00426 General Inspection10/31/201710/31/201710/31/2017 4:56:34 PMPPEND
Dewatering follow up inspection. In the morning 10/31 construction activity was halted as crews worked to plug irrigation piping to halt turbid water from discharging into Spoil Banks Canal.

Discharge has now stopped and water has not yet backed up in manholes to overflow to barrow ditch. Once entering the ditch there is approximately 100 M of vegetated channel. Water should infiltrate before reaching the creek.

Flow to continue through tomorrow. Will need follow up inspection tomorrow.

Turbidity sample at discharge point to canal was 166 NTU. Upstream, the canal at Pierce Park is 10 NTU. Downstream , approximately half mile from site at Gillis Street bridge was between 10 -11 NTU. A debris dam just below the discharge point in the creek has created a deeper pool where turbid water is trapped and is settling out.
ESC17-00426 General Inspection10/31/201710/31/201710/31/2017 4:46:21 PMAPEND
Construction halted to improve dewatering system to prevent turbid discharge.

Discharge this morning to Spoil Banks Canal was turbid.
ESC16-01265 Aging Inspection10/31/201710/31/201710/31/2017 12:45:42 PM CANC
ESC16-01352 Aging Inspection10/31/201710/31/201710/31/2017 12:45:26 PM CANC
ESC16-01434 General Inspection10/31/201710/31/201710/31/2017 12:45:17 PM CANC
ESC16-01268 Aging Inspection10/31/201710/31/201710/31/2017 12:45:06 PM PASS
ESC17-00526 General Inspection10/31/201710/31/201710/31/2017 12:43:37 PMPPASS
WIP on new bathroom facility foundation. Permit sign posted, utilizing Ecopan concrete washout.

No trackout from site, perimeter controls install between project and Quinn's Pond. No corrections needed.
ESC17-01146 BMP Violation10/31/201710/31/201710/31/2017 12:27:03 PMAPEND
Each site to provide own washout facility or have hauled offsite. Asbury Construction on notice for multiple violations and lack of housekeeping at projects in Millwell.
ESC17-01034 Conference10/31/201710/31/201710/31/2017 12:25:59 PMAPASS
Pre-construction conference call. Approved to begin activities at site, will post ESC permit, protect inlets on Enterprise, and provide concrete washout.

RP aware of ESC permit requirements. Approved.
ESC17-01016 BMP Violation10/31/201710/31/201710/31/2017 12:05:51 PMAFAIL
No permit sign posted
No regular clean up or containment of backfill
No washout provided

Further enforcement pending. VM left to RP Andrina
ESC17-00390 BMP Violation10/31/201710/31/201710/31/2017 11:48:09 AMAFAIL
Correction notice posted:

- sweep up sidewalk and gutter
- pick up uncontained trash
- get valid RP on permit sign

NO correction by end of day 11/1/2017 will result in re-inspection fee/SWO
ESC17-00389 BMP Violation10/30/201710/31/201710/31/2017 11:39:52 AMAFAIL
Correction request issued to remove uncontained trash pile at site before end of week.
ESC17-00044 Site Final10/31/201710/31/201710/31/2017 10:43:44 AMPNR
DI bags left behind after stabilization of projects in Belmar. Need to remove DI bags to final ESC permits still open.
ESC16-01243 Site Final10/31/201710/31/201710/31/2017 10:43:26 AMPNR
DI bags left behind after stabilization of projects in Belmar. Need to remove DI bags to final ESC permits still open.
ESC16-01243 Aging Inspection10/31/201710/31/201710/31/2017 10:42:34 AM FAIL
Project complete and stabilized. No removal of temporary BMP storm drain inlet at the south end of streeet.

Correction to Downey and/or ZEC to remove DI bags in Belmar.
ESC17-00642 DOC - Permit Finaled10/31/201710/31/201710/31/2017 10:37:04 AMPPASS
ESC17-01479 General Inspection10/31/201710/31/201710/31/2017 10:31:19 AMAPASS
Dewatering follow up.

Water from trenching is remaining onsite for infiltration. A ditch has been extended along the west and north site perimeter.

Will need to continue to extend ditch for more capacity.

No offsite discharges or trackout.
ESC17-00426 Stop Work Order10/31/201710/31/201710/31/2017 9:17:10 AMAFAIL
Dewatering project with turbid discharge into Spoil Banks Canal. Corrective actions in place since 10/27 not settling or removing sediment and turbidity plume.

Issued verbal SWO to Wood Bros. RP to get new dewatering plan and setup and have inspected with proof of treated discharge. Working to re-direct water to Millwell Pond for infiltration.
ESC16-01379 Aging Inspection10/31/201710/31/201710/31/2017 8:49:24 AM CANC
ESC02-00671 DOC - Permit Finaled10/31/201710/31/201710/31/2017 8:02:15 AMPPASS
old expired permit closed from database
ESC16-01421 General Inspection10/31/201710/31/201710/31/2017 8:00:17 AM CANC
ESC16-01719 General Inspection10/31/201710/31/201710/31/2017 7:56:20 AM CANC