Inspections for the day of: Friday, October 4, 2019.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01524 Site Final10/3/201910/4/201910/9/2019 12:58:34 PMACANC
ESC18-00652 General Inspection10/4/201910/4/201910/9/2019 12:58:04 PM CANC
ESC18-01595 Site Final9/27/201910/4/201910/9/2019 12:35:05 PMPPASS
ESC18-01089 General Inspection10/4/201910/4/201910/9/2019 12:31:41 PM PART
Corrections needed:

- clean up dumped washout. Post notice about dumping on ground and service.
- sweep up trackout from retaining wall installation crew
- install perimeter sediment control on lot 9 block 2 in Harris north 3 (corner of Foxgrove and Hootowl)
ESC18-01194 Site Final9/26/201910/4/201910/7/2019 3:05:36 PMPPASS
Home landscaped/stabilized. Subdivision RP to remove temporary BMPs
ESC18-00803 General Inspection10/4/201910/4/201910/4/2019 2:49:25 PM CANC
ESC18-00803 Site Final10/4/201910/4/201910/4/2019 2:49:10 PMPPASS
No disturbed area or temp. BMPs. Permit closed.
ESC19-00566 General Inspection10/4/201910/4/201910/4/2019 2:46:36 PMPPASS
RP on duty. No trackout. Concrete washout pan and perimeter wattles installed. Approved.
ESC18-01441 Aging Inspection10/4/201910/4/201910/4/2019 2:27:02 PM PASS
Home near completion. No trackout. No spills or other violations observed.
ESC19-00841 BMP Violation10/4/201910/4/201910/4/2019 2:25:37 PMPFAIL
No trackout or discharges. Concrete washout pan onsite.

BMP missing - need to install storm drain sediment protection on MS4 on Boise Ave. No ESC permit sign posted.

Onsite RP Nate said it will be done. Follow up scheduled.
ESC18-01339 Aging Inspection10/4/201910/4/201910/4/2019 2:07:04 PM CANC
rescheduled for site final
ESC18-01235 General Inspection10/4/201910/4/201910/4/2019 12:47:08 PM FAIL
Corrections needed:

- empty full trash bin, pick up loose trash around site, in particular in the grasses/weeds on the view side of home
- crew doing sidewalk dumped concrete washout on ground instead of using lined washout pit. RP notified to clean up and put sign on washout.
- construction entrance needs re-installlation

Note: wip regrading fill area where stockpile was pushed. Will install stabilzation and erosion controls after work. No issues in this area at this time.
ESC17-00155 Site Final9/30/201910/4/201910/4/2019 12:12:50 PMPPASS
ESC19-00200 Site Final10/4/201910/4/201910/4/2019 11:53:28 AMPPASS
ESC19-00199 Site Final10/4/201910/4/201910/4/2019 11:53:04 AMPPASS
ESC18-00919 Site Final10/4/201910/4/201910/4/2019 11:17:33 AMPPASS
ESC19-00208 Site Final10/4/201910/4/201910/4/2019 11:15:20 AMPPASS
HOme complete. NO ESC requests. Pool still under construction, see ESC19-01244
ESC18-00919 Site Final10/4/201910/4/201910/4/2019 11:13:50 AMPPASS
ESC19-00574 General Inspection10/4/201910/4/201910/4/2019 11:06:49 AMAPART
No significant trackout or offisite discharges. Permit and SWPPP info posted and plan onsite in trailer. Site is completing inspections once every week, no corrective actions noted.

Site is dewatering per the dewatering plan. Discharge into settling area and pond is clear and clean.

Crews currently working on east access area to VMP. Site has been gradeded and is still active. Surround by grass and perimeter sediment control wattles. Site has leakproof concrete washout.

Correction requests:
- clean up mud in front of storm drain at end Lander Street parking, maintain sediment bag installed.
- clean up/absorb oily sheen near the drain mentioned above
- construction entrance is less than the required 50 ft.
- unable to find BMP construction details in SWPPP, please insert and check all installations.
- Some wattles are not trenched in and have loose stakes around the Willow Lane pond (note: vegetative buffer on downslope side of wattles is preserved)
- update grading and stabilization log in SWPPP
ESC18-01405 Aging Inspection10/4/201910/4/201910/4/2019 8:24:28 AM CANC
ESC18-00497 General Inspection10/4/201910/4/201910/4/2019 8:23:34 AM CANC