Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00371 General Inspection10/9/201910/9/201910/11/2019 12:43:48 PMPPASS
Inspection Wednesday 10-9

No trackout at entrances. Crew installing pipe on Vortex. Areas at final grade have had stabilization measures implemented.

Some areas of wattle installation are not staked properly, notified installation crew.

No corrections at this time. Will follow up with full site walk through
ESC17-00774 General Inspection10/9/201910/9/201910/9/2019 12:58:47 PM CANC
ESC18-00652 BMP Violation10/9/201910/9/201910/9/2019 12:57:44 PMPFAIL
New RP is Mark Roberts 2082069096

Full trash, loose trash, no ESC permit sign, dumped stucco washout and material. Construction entrance is not installed per BMP requirements.

ESC19-00084 Site Final10/9/201910/9/201910/9/2019 12:34:07 PMPPASS
ESC19-00119 Site Final10/9/201910/9/201910/9/2019 12:33:49 PMPPASS
ESC19-00942 General Inspection10/9/201910/9/201910/9/2019 12:32:18 PMPPASS
WIP. Subdivsion BMPs installed (DI protection, onsite RP, concrete washout facilities)
ESC18-01208 Aging Inspection10/9/201910/9/201910/9/2019 12:19:05 PM CANC
rescheduled for site final
ESC17-01491 General Inspection10/9/201910/9/201910/9/2019 12:18:19 PM CANC
ESC18-01178 General Inspection10/9/201910/9/201910/9/2019 11:39:15 AM PART
WIP on finishing home. Yard is landscaped. There is disturbed area around the perimter of the yard, needs to be stabilized and have down gradient sediment control.

Correction request
- sweep up gutter and parking areas in front of home
- provide plan for ESC controls on the disturbed areas outside of the landscaping.
- pick up loose trash around perimeter.
- schedule site final inspection.

No trackout or discharges
ESC19-00862 General Inspection10/9/201910/9/201910/9/2019 10:58:11 AMPPASS
ESC19-01269 General Inspection10/9/201910/9/201910/9/2019 10:49:16 AMPFAIL
Dumped washout in back of lot, no containment provided.

1st violation for Avimor Partners - warning and request to clean up.

Notified RP Brad any further dumped washout will be automatic parcel hold and re-inspection fee.

Permit posted, no other violations at site.
ESC18-01450 General Inspection10/9/201910/9/201910/9/2019 10:41:48 AM PASS
Exterior work complete. No disturbed area or temp BMPs observed.. BLD open for interior plan modification. ESC permit finaled.
ESC18-01450 DOC - Permit Finaled10/9/201910/9/201910/9/2019 10:40:37 AMPPASS
ESC18-00446 Aging Inspection10/9/201910/9/201910/9/2019 9:22:39 AM PASS
ESC18-01333 General Inspection10/9/201910/9/201910/9/2019 8:12:46 AM CANC