Inspections for the day of: Wednesday, November 14, 2018.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-00069 Site Final11/8/201811/14/201811/15/2018 2:24:05 PMPPASS
Work complete. No temporary sediment controls left in work areas along 8th Street, Freak Alley, Union Alley, and Capitol Blvd. ESC permit finaled
ESC18-01121 General Inspection11/14/201811/14/201811/14/2018 4:23:04 PMPPASS
WIP on compaction and preparation for foundations in dewatered river channel between cofferdams. River bottom material and concrete chunks have been removed. Water returning to the River from diversion pipe and well heads in channel is clear and was not churning up sediment at discharge point.

At upriver end of project the future channel to establish the habitat island is starting to be excavated. The material is then being hauled for fill into Veterans Pond along the canal side & future pathway route.

The area of fill at Veterans Pond has a turbidity curtain containment. A slight murkiness of the water leaving the pond and joining the diverted river water in Farmers Union was observed. Turbidity test at 12:45 today showed 28.4. Turbidity log was availalbe upon request. The result is above background levels but not above the 50 NTU limit. Samples taken in previous days were below 5.0 NTU. No visible plume was seen with the river water in Farmer's Union.

Other BMPs observed were secondary spill containment areas in staging yard and water truck working the haul routes to keep dust down.
ESC17-01285 Aging Inspection11/14/201811/14/201811/14/2018 2:39:19 PM CANC
rescheduled for site final
ESC17-00836 General Inspection11/14/201811/14/201811/14/2018 2:38:40 PM CANC
ESC17-01720 General Inspection11/14/201811/14/201811/14/2018 10:17:12 AM PASS
All permits finaled. No disturbed area or temp BMPs remaining. No corrections.
ESC17-01720 DOC - Permit Finaled11/14/201811/14/201811/14/2018 9:42:55 AMPPASS
ESC18-00280 General Inspection11/14/201811/14/201811/14/2018 9:40:15 AMPPART
Site is currently inactive. No trackout, discharges, or wind blown dust observed. No crews or equipment at site. Utilty and site work is complete, Silt fence perimeter along Ridenbaugh Canal is installed and in tact.

Correction needed:
- pick up and contain loose trash scattered around the site.
- update SWPPP inspection book
ESC18-00792 General Inspection10/29/201811/14/201811/14/2018 9:36:58 AMAPASS
Silt fence perimeter installed. No trackout to Dentron, stabilized entrance installed. Lined washout pit is nearby entrance/exit at corner of
Curtis and Denton. Storm drains have sediment protection. No fugitive dust observed. WIP on foundations. No corrections requested.