Inspections for the day of: Tuesday, November 5, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01772 General Inspection11/5/201911/5/201911/6/2019 3:49:02 PM PASS
ESC18-01283 General Inspection11/5/201911/5/201911/6/2019 3:48:50 PM PASS
No trackout, discharges or other violations observed. WIP on vertical
ESC19-01269 General Inspection10/16/201911/5/201911/6/2019 2:04:05 PMPPASS
ESC19-01158 General Inspection11/5/201911/5/201911/6/2019 8:35:17 AMPFAIL
No concrete washout pan or lined pit set up for concrete work as requested and warned about. Fine and parcel hold issued on ESC19-01166. Follow up Friday
ESC19-00994 General Inspection11/5/201911/5/201911/5/2019 4:01:49 PMPFAIL
Corrections needed:

- install additional riprap for the piped outlet west of Bogus Basin Road

- check for correct wattle installation

ESC17-00190 General Inspection11/5/201911/5/201911/5/2019 4:00:14 PMPFAIL
Inspection 11/4

Need to install additional stormwater controls at top of culdesac to handle increased runoff from the grazed area above the culdesac. We had erosion here last year and there is risk of further erosion this year due to the near bare conditions.

Notified RP Scott, he will install additional wattles and assess the area.
ESC18-00863 DOC - Permit Finaled11/5/201911/5/201911/5/2019 3:56:18 PMPPASS
ESC19-00995 Complaint Inspection11/5/201911/5/201911/5/2019 3:37:06 PMPPART
notified of a turbid discharge spotted in this area during an aerial/LIDAR survey of the Boise River

Potential that crew cleared a debris dam in the drainage canal that runs through the south side of the site and caused some turbidity. Removal of this dam seem to have increased the flow of the water which may also be stirring up silt/mud on the canal bed.

There is also beaver activity and maintenance of the canal culvert (due to clogging from beaver cuttings/mud dams) that may cause brief turbidity and upstream in DD3 drainage through Ann Morrison that could have been a potential source.

Turbidity samples: outlet to Boise River in Garden City (Crab Shack)) = 14 NTU around 1:30. Plume was visible at 1 PM

- Site discharge monitoring location in canal 27 NTU

Upstream in canal between debris clearing (west of the rookery shelter) 28 NTU

- midway debris dam in drainage canal just past the cleared area 62 NTU

- downstream side of culvert for outlet of first drainage channel pond area 10.4 NTU (*this is where there is beaver activity)

- pond inlet culvert from Ann Morrison 9.55 NTU


No readings over 50 NTU incidental limit to the Boise River, but if there is any channel work or activity in water, turbidity monitoring and observation of plumes should occur.

Correction request: During work on piers for future viewing decks, suggested a coffer dam or diversion of flowing water in canal and have turbidimeter onsite at time of work in case of any visible plumes. This event should be noted in the SWPPP, potentially in the Corrective Actions to have a protocol for any in-channel work.
ESC18-01089 General Inspection11/5/201911/5/201911/5/2019 11:06:04 AM CANC
ESC18-01266 Aging Inspection11/5/201911/5/201911/5/2019 11:01:35 AM PASS
ESC18-01266 Site Final11/5/201911/5/201911/5/2019 11:01:22 AMPPASS
Home landscaped, no disturbed area or loose materials. No temp. BMPs left on site or receiving storm drain.
ESC18-01022 Conference10/30/201911/5/201911/5/2019 7:46:12 AMPCANC
1:30 PM lower entrance

winterization