Inspections for the day of: Wednesday, December 20, 2017.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00513 Site Final12/20/201712/20/201712/22/2017 12:53:59 PMPNR
NR- not ready for site final

WIP. Two soccer/football fields complete and have turf, one softball/baseball field. Frontage along Fort still in progress. No trackout or discharges, no loose trash or materials exposed.

Permit is open. No corrections requested.
ESC17-01744 Conference12/20/201712/20/201712/21/2017 12:06:06 PMAPEND
complaint doing work outside of the permitted area in the pasture area on Forsythia street. Please call Tisha.

Excavated area in field near Forsythia was for gathering fill dirt for another home project in different location. Some trench excavation right at the house at 3311 Hill. No dirt leaving site. Permit sign posted, no trackout. No workers on site at time of inspection.

Will notify developer that no grading or earth work associated with new residential subdivision is allowed until further approvals, submitting ESC site plan and filing for EPA CGP coverage


ESC16-00936 BMP Violation12/20/201712/20/201712/21/2017 11:56:01 AMPPART
report of uncontained washout

No washout onsite. Uncontained washout pile has remained on lot and did not go to gutter. Contractor will clean up.

No trackout, slope stabilization and sediment controls at bottom of site are installed properly and in working condition.
ESC15-00857 General Inspection12/20/201712/20/201712/20/2017 9:35:22 AM PASS
No significant trackout at construction access road, but will need more heavy duty angular rock once use increases. No erosion or drainage issues along road, large retention pond located at bottom of hill to capture runoff.

1 SFH in progress on Eyrie Way. No subdivision work. Storm drain sediment controls, hillside wattles and vegetation, and drainage ditches with check dams on Arrow Villa are in good condition. No corrections requested.
ESC14-01063 General Inspection12/20/201712/20/201712/20/2017 9:04:37 AM PASS
Storm drains have sediment protection, lined concrete washout onsite, and slopes around Goshawk are well vegetated. No activity of SFHs at time of inspection.

No violations observed.