ESC19-00324
| General Inspection | 2/10/2020 | 2/10/2020 | 2/13/2020 8:32:26 AM | P | PEND |
|
|
Sidewalk base preparation and placement in progress. Washout pan onsite.
Track Utilities still active, but should be done next week, at which time silt fence and other BMPs will be added.
Crews will be working on rebuilding, extending, and strengthening retention berms.
Corrections are not complete, but RP has schedule and plan to get site ready to handle more precipitation. Follow up scheduled
|
ESC16-00935
| General Inspection | 2/10/2020 | 2/10/2020 | 2/12/2020 2:49:13 PM | | PEND |
|
|
No significant changes. Did not check to see if silt fence had been removed. No new erosion issues observed. Bentonite clay is plugging hole in slope. Will follow up
|
ESC18-01171
| General Inspection | 2/10/2020 | 2/10/2020 | 2/12/2020 2:17:22 PM | | PASS |
|
|
WIP. No offsite trackout or disturbances observed.
|
ESC18-01767
| General Inspection | 2/10/2020 | 2/10/2020 | 2/11/2020 2:27:58 PM | | PASS |
|
|
Work occuring on interior. No trackout, spills, discharges around site. Workers parking on street.
|
ESC19-00116
| General Inspection | 2/10/2020 | 2/10/2020 | 2/11/2020 11:09:11 AM | | CANC |
|
|
rescheduled
|
ESC19-01749
| Site Preparation | 2/10/2020 | 2/10/2020 | 2/11/2020 11:08:29 AM | P | NR |
|
|
Initial site work and demolition has started. No discharges or trackout, but no perimeter BMPs installed yet or construction entrance off Alpine. Receiving storm drain is on Alpine several blocks to the west. Will recommend gutter bag check dam instead of filter bag.
NO crew onsite at time of inspection, voicemail box of RP is full. Will try again.
|
ESC19-00041
| General Inspection | 2/10/2020 | 2/10/2020 | 2/11/2020 8:19:15 AM | | CANC |
|
|
|
ESC19-01584
| Site Preparation | 2/10/2020 | 2/10/2020 | 2/10/2020 3:36:36 PM | P | PASS |
|
|
Site prep requested by Kade with Capital Paving.
WIP on sewer connection. Small volume of trench dewatering being contained on site. Construction entrance installed. Crews parking on the pavement. No ESC requests at this time.
Approved.
|
ESC19-00178
| General Inspection | 2/10/2020 | 2/10/2020 | 2/10/2020 1:03:43 PM | | CANC |
|
|
rescheduled for site final
|
ESC20-00041
| Site Preparation | 2/10/2020 | 2/10/2020 | 2/10/2020 1:02:35 PM | P | PASS |
|
|
Construction entrance installed on Linda Vista. This permit is for the demolition, which is complete. The Glen Place subdivision permit has not been issued yet. No violations, need subdivsion permit to be issued for further work to occur.
|
ESC19-01053
| Tracking Control | 2/10/2020 | 2/10/2020 | 2/10/2020 12:59:02 PM | P | FAIL |
|
|
Workers parking in mud, some driving through mud and over curb instead of using construction entrance.
Correction request to sweep Cole southbound and to thoroughly sweep the gutter. Storm drain on Cole has grate that is asphalt into place so no sediement bag can be installed.
RP said he will work on getting more stabilized parking and have sweeeper come tonight or Tuesday. Follow up inspeciton Wednesday
|
ESC18-00755
| General Inspection | 2/10/2020 | 2/10/2020 | 2/10/2020 12:43:18 PM | | PEND |
|
|
All permits finaled. No construction occuring. Daycare staff parking in muddy area and causing some minor trackout.
Will inquire with P&Z about requiring a paved or gravel parking lot.
|
ESC18-01466
| Conference | 2/7/2020 | 2/10/2020 | 2/10/2020 11:25:37 AM | P | PASS |
|
|
Ecopan washout now staged onsite. Posted ESC permit sign at front of site. Most of crew is parked on street, some vehicles and equipment parked in mud within site. Minor trackout to Benjamin.
Discussed construction entrance installation, currently no rock entrance installed. Plan is to remove mud layer that has collected on top of preveiously placed pit run and install more pit run to build up site and prevent mud. Parking lot to installed March, in meanwhile will do sweeping and trackout control until more material can be placed.
|
ESC19-01525
| Site Preparation | 2/7/2020 | 2/10/2020 | 2/10/2020 10:58:46 AM | A | PASS |
|
|
10 AM with RP Roger and Brandt Hospitality superintendant Angela ###-####
Two construction entrances, silt fence perimeter on 3 lower sides of site, placed pit run in site to keep mud down. Grass and trees around the cleared area have been preserved. Water truck, sweeper, and dumpster have been staged. Receiving storm drains (private & MS4) have sediment protection installed. Responsible Person on duty. Will post Boise ESC permit sign on Rifleman and on trailer.
Approved for construction,
|
ESC17-01484
| Aging Inspection | 2/10/2020 | 2/10/2020 | 2/10/2020 8:14:13 AM | | CANC |
|
|
|
ESC18-00647
| Aging Inspection | 2/10/2020 | 2/10/2020 | 2/10/2020 8:12:57 AM | | CANC |
|
|
|