PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Thursday, February 14, 2019
.
Number of inspections:
12
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC18-00363
General Inspection
2/14/2019
2/14/2019
2/19/2019 10:27:37 AM
CANC
ESC18-00417
Aging Inspection
2/14/2019
2/14/2019
2/19/2019 10:27:31 AM
CANC
ESC17-00954
Conference
2/13/2019
2/14/2019
2/15/2019 3:56:11 PM
A
FAIL
Inspection and site conference with RP and the two SFH RPs that are in progress conducted at 10:30. Turbidity sampling conducted at site and at outfall to Crane Creek, tributary to the Boise River.
-Significant Violation: Illicit stormwater discharge due to runoff polluted with eroded sediment. On February 14th at 10:30 AM, turbidity samples taken in gutter directly below site on Winsome were above the measurement level of 1000 NTU. Crane Creek outfall discharge at 170 NTU. Visible plume in Crane Creek from outfall observed on February 13th at 4:00 PM.
-Significant Violation: Uncontained concrete washout dumped and never cleaned on lot 11, pH of runoff from was 10.8 on digital pH monitor.
-Routine Violation: Unmaintained/damaged BMPs on site. Notification given of retention berm damage on February 4th provided to Responsible Person, no effective corrective actions were implemented. No crew or RP onsite Wednesday PM during heavy rain to monitor and address issues.
-Routine Violation: ESC BMPs are not installed per the approved ESC plan
Notice of Violation issued to site. Over 2 hours and two ESC inspectors investigating the site for this inspection.
ESC17-00842
General Inspection
2/14/2019
2/14/2019
2/15/2019 3:54:58 PM
P
CANC
ESC16-00406
General Inspection
2/14/2019
2/14/2019
2/15/2019 3:52:47 PM
CANC
ESC18-00311
General Inspection
2/14/2019
2/14/2019
2/15/2019 3:52:37 PM
CANC
ESC18-00946
General Inspection
2/12/2019
2/14/2019
2/15/2019 3:49:55 PM
P
PEND
RP-GC was on site 2/14 working on BMPs to prevent discharge. There was some muddy runoff flowing under wattles in a few spots adding to the turbidity in the gutter (315 NTU)
RP has contracted with Gatorguard to install a full set of BMPs including a slope drain to convey water down from upper level to the road without causing additional erosion.
ESC18-01433
Conference
2/14/2019
2/14/2019
2/15/2019 1:14:45 PM
P
FAIL
Inspection conducted 10:30 2/14
Muddy runoff coming down large rill parallel to the construction entrance and overtopping and under cutting gatorguard check dams.
Verbal correction request to install check dams to slow water velocity and trap sediment, install silt fence to contain the upper area.
Corrections were started while on site. Follow up inspection scheduled.
ESC18-01455
Conference
2/14/2019
2/14/2019
2/15/2019 1:12:19 PM
P
FAIL
see ESC17-00954
ESC18-01244
Conference
2/14/2019
2/14/2019
2/15/2019 1:11:37 PM
P
FAIL
Muddy runoff, runoff from uncontained concrete washout dump, and other issues at site.
Need to clean up, schedule removal of the concrete washout ASAP. Install fence on adjacent lot to prevent unauthorized access.
If not completed by end of Month, the site will be issued a SWO.
Verbal correction request to RP-homeowner Brad.
ESC19-00088
DOC - Permit Finaled
2/14/2019
2/14/2019
2/14/2019 4:28:48 PM
P
PASS
see ESC18-01432 for ESC permit coverage and inspection activity.
ESC17-01360
General Inspection
2/14/2019
2/14/2019
2/14/2019 1:36:03 PM
CANC