Inspections for the day of: Thursday, March 17, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC14-00356 DOC - Permit Finaled3/17/20163/17/20163/17/2016 12:49:24 PMPPASS
ESC15-00463 General Inspection3/17/20163/17/20163/17/2016 12:44:39 PM PASS
No trackout. No discharges. Trackout from last week was cleaned up and new rock installed on construction entrance. Front slope vegetation was preserved and perimeter wattle installed as well as DI sediment bag. Approved.
ESC15-01210 General Inspection3/17/20163/17/20163/17/2016 12:40:36 PMPPASS
Re-inspection to lift SWO and check for corrections issued 3/14

Gutters and storm drain inlets were cleaned out and sediment filters re-installed as requested.

Additional sediment control wattles and check dams were installed at bottom of site to filter runoff.

Graded area that was added to permit has had slope stabilization and sediment control wattles installed. RP stated that disturbed slopes no longer with work remaining are to be hydroseeded this April.

SWO lifted, remaining corrections include:
- pay re-inspection fee
- install new temporary retention pond somewhere in middle of the project to capture and slow down runoff from the upper end of project so that there is not some much runoff exitting site at bottom all at once.

Pat stated he will make these corrections asap.

Approved for construction to resume. GRD and ESC permit now in compliance with submitted plans.
ESC15-00177 DOC - Permit Finaled3/17/20163/17/20163/17/2016 12:34:04 PMPPASS
ESC12-01066 General Inspection3/17/20163/17/20163/17/2016 12:19:42 PM PASS
No futher ESC inspections. DI bag on private drain to be removed by 951 property manager. DI on Front is utilized for the bridge staging yard and can be removed at later date. Has a lot of capactity. No futher inspections on this permit.
ESC12-01066 DOC - Permit Finaled3/17/20163/17/20163/17/2016 12:13:22 PMPPASS
ESC15-01058 Aging Inspection3/17/20163/17/20163/17/2016 11:22:14 AM PASS
WIP. Subdivsion BMPs installed. No trackout or discharges. No corrections.
ESC15-01056 Aging Inspection3/17/20163/17/20163/17/2016 11:22:02 AM PASS
WIP. Subdivsion BMPs installed. No trackout or discharges. No corrections.
ESC15-01062 Aging Inspection3/17/20163/17/20163/17/2016 11:01:59 AM PASS
Home construction complete and sale pending. BLD finaled. ACtive homes in progress all around house with same builder with ESC permits. Subdivsion BMPs installed.

Yard to be landscaped by homeowner. No further ESC inspections on this permit.
ESC15-01062 DOC - Permit Finaled3/17/20163/17/20163/17/2016 11:00:30 AMPPASS
ESC15-01291 Site Final3/16/20163/17/20163/17/2016 10:59:22 AMAPASS
Victor Phone #: ###-####

Paving work is complete. Minor landscaping and irrigation occuring within site. No temp BMPs installed. NO further ESC inspections required.
ESC15-01291 DOC - Permit Finaled3/17/20163/17/20163/17/2016 10:57:18 AMPPASS
ESC15-00033 BMP Violation3/16/20163/17/20163/17/2016 9:33:26 AMPPEND
Verbal CN to install check dam filter bags to the east of the access point to the Honda parking lot that is being finished. This will be okay instead of installing DI bag on inlet on Auto Drive that is 1/4 mile from site.

Need to sweep up track out to Gratz.

24 HR compliance time. RP Tony said it will be done ###-####
ESC16-00323 Site Preparation3/17/20163/17/20163/17/2016 9:23:21 AMPPASS
Please call Jill prior to going out. Phone #: ###-####

Demolition within industrial/commercial staging yard. No MS4 in area.

Dust control and trackout control required. Permit sign posted.