Inspections for the day of: Wednesday, March 2, 2016.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-00463 General Inspection3/2/20163/2/20163/4/2016 2:24:42 PM CANC
ESC13-01159 General Inspection3/2/20163/2/20163/4/2016 1:10:12 PM PASS
ESC14-00432 General Inspection3/2/20163/2/20163/3/2016 2:16:18 PM PASS
WIP on SFHs by Hayden Homes. No corrections issued.
ESC15-01104 Aging Inspection3/2/20163/2/20163/3/2016 11:31:55 AM PASS
Work complete. No disturbed area. No loose sediment or other materials leaving site.
ESC16-00175 Site Preparation3/2/20163/2/20163/2/2016 4:33:58 PMPPASS
RP on site. Reieweed ESC plan. BMPs installed include an angular rock construction entrance and a DI bag on the storm drain on Clubview.


Vegetative perimeter with grass and trees are to be undisturbed, creating a sediment barrier. Grading will be done to direct sheet flow inward for onsite retention. Current stockpile is to be spread across the park area, no off haulig required.

Approved for construction. Permit sign posted on billboard at site entrance.
ESC14-00588 Tracking Control3/2/20163/2/20163/2/2016 4:01:33 PMPPART
Correction request to sweep the paved apron between the tracking pad and ROW.

Streets are being swept 1x per week and apron swept as needed. Requested that it be swept at a minimum of once a week and more if trackout is occuring.
ESC15-00915 Aging Inspection3/2/20163/2/20163/2/2016 3:59:21 PM CANC
ESC15-00921 Aging Inspection3/2/20163/2/20163/2/2016 3:37:23 PM PASS
Project complete. ESC conditions satisfied.
ESC15-00921 DOC - Permit Finaled3/2/20163/2/20163/2/2016 3:36:47 PMPPASS
ESC15-00921 DOC - Permit Finaled3/2/20163/2/20163/2/2016 3:16:20 PMPPASS
ESC15-00765 Aging Inspection3/2/20163/2/20163/2/2016 2:56:45 PM PASS
Construction complete. ESC conditions satisfied. All permits finaled.
ESC15-00765 DOC - Permit Finaled3/2/20163/2/20163/2/2016 2:54:45 PMPPASS
ESC16-00159 General Inspection3/2/20163/2/20163/2/2016 2:51:26 PMPPART
Grading work in progress. No fugitive dust and no major trackout.

Correction needed: Construction entrance needs maintenance and the correct size rock if hauling is going to occur.

Investigated the work occuring in Warm Springs Creek channel. The work is detailed and approved in the grading plans and is widening the channel to 8 feet leading up to rip rapping it under the road culvert. Work appears to have remained within the designated area of disturbance.

This creek will need stabilization and erosion control as soon as possible as there is no diversion for runoff and rain water in the Warm Springs Creek. The creek is flowing at Barber Road but soaks into the groud approximately 1/4-1/3 mile upstream of the construction in the horse/cow pasture.
ESC15-01362 General Inspection3/2/20163/2/20163/2/2016 1:57:30 PMPPASS
No violations observed. WIP. Housekeeping duties satisfied. Hillside vegetation and boulders left undisurbed below home.
ESC15-01188 General Inspection3/2/20163/2/20163/2/2016 1:53:51 PMPPART
Foothills existing vegetation in and around parcel has been left undisturbed. No trackout, no accumulated sediment/dirt in gutters or culdesac.

Correction needed:
- conduct maintenance/replace inlet filters at Birdsong and Windsong.
ESC15-00660 General Inspection3/2/20163/2/20163/2/2016 1:51:27 PM PASS
WIP. Vegetative buffer preserved around site slopes. No sediment runoff or erosion rills observed. No trackout from entrance. No windblown litter issues. Approved.
ESC16-00242 General Inspection3/2/20163/2/20163/2/2016 9:14:58 AMAPASS
Inspection notes continued from 2/29:

After reviewing the SWPPP, we performed a site walk through and review of BMPs.
• All runoff from the construction site flows into Micron’s permanent storm water treatment and retention facilities. There were no non-point sources or direct outlets offsite. These include catch basins, sand and oil interceptors, a large retention pond, and a flow control device at the outlet to the creek. Micron is monitors storm water discharges for their industrial operations (MSGP) including testing for pollutants. Flow out of the pond may also be stopped altogether if necessary.
• Temporary BMPs have been installed to protect the permanent storm water infrastructure and treat construction site storm water runoff. The installation of sediment filter bags on all receiving catch basins was done properly. These are checked during each inspection and maintained regularly per the Storm water Team. No full bags were observed.
• Around the site it appeared that any loose sediment on roads and parking lots were swept up regularly. A heavy duty rock construction entrance is installed for construction traffic. The areas around the site were very clean.
• All waste materials are contained and hazardous materials collected for proper disposal per RCRA requirements for Micron’s operations. A designated staging and stockpiling area has been provided to the northeast of the construction area. A leak-proof concrete washout facility and silt fence perimeter are noted in the SWPPP.
• A perimeter sediment control is installed around the building footprint. It consists of filter fabric buffer strip covered with rock. Sheet flow off the paved surfaces passes through this filter and traps sediment before flowing towards the gutters and catch basins.
• No fugitive dust issues observed at time of inspection.
• City of Boise ESC permit sign and CGP permit signage posted clearly at Gate C on Federal Way.
• We did discuss use of the straw wattles and filter fabric installed at the outlet to Fivemile Creek that had been observed prior to this inspection. After review of the onsite treatment and BMPs and that these installations are not intended to be the primary filtering BMPs, they are not causing any apparent damage and may be used at the discretion of the project’s Stormwater team.
The inspection passed the review. No violations were observed and no corrective actions issued.