Inspections for the day of: Tuesday, March 3, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC19-00574 General Inspection3/3/20203/3/20203/4/2020 8:25:05 AM PASS
Construction entrance, perimeter controls, concrete washout are all installed and in use. No trackout or fugitive dust occuring.

Dewatering in progress, next week they will be digging down further for the sewer lift station so dewatering activity will change.

SWPPP inspections, turbidity log, and grading and stabilization log are being completed.

Requests:

- add baffles to dewatering basin; have an extra pit for excavation water to not mix with the deep well point water

- move SWPPP sign and board to the front of the project, currently on the Lander side of site

Noified RP Dustin
ESC17-01088 General Inspection3/3/20203/3/20203/4/2020 8:20:25 AM PASS
No activity. 2 open lots remain. No active construction. Storm drains have sediment protection still installed. Going to request to developer to remove sign and storm drain bags
ESC19-00371 General Inspection3/3/20203/3/20203/3/2020 2:42:07 PMPPASS
Minor activity prepping sidwalk and gutter areas on upper section.

NO trackout or discharges from site. Dry conditions.

Corrections needed:

- repair/reinstall silt fence below main entrance & above phase 6 pond
- pick up loose trash at the discharge point. Stuck in bushes
- remove dewatering bag

ESC19-01083 Site Final3/3/20203/3/20203/3/2020 10:44:26 AMPPASS
Home complete and landscaped. No ESC requests
ESC19-00534 Site Final3/3/20203/3/20203/3/2020 10:43:54 AMPPASS
Home complete and landscaped. No ESC requests
ESC19-00935 General Inspection3/3/20203/3/20203/3/2020 10:36:41 AMPPART
No activity, no trackout. Dry conditions. No wind blown dust observed at time of construciton.

Corrections needed:
- updated construction schedule
- stabilize stockpile or become active. Beyond stockpile stabilization deadline
- install new construction entrance prior to resuming grading activity

Notified RP John. He will provide updates and schedule on corrections.

Follow up inspection scheduled
ESC18-00659 General Inspection3/3/20203/3/20203/3/2020 9:58:15 AM PEND
BMPs installed on frontage lot; not yet stabilized
ESC19-00972 DOC - Permit Finaled3/3/20203/3/20203/3/2020 8:02:11 AMPPASS
see ESC18-00659 for rest of King Street/Fairview apartment inspections