Inspections for the day of: Monday, April 1, 2019.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MIS19-00074 ESC-Conference3/28/20194/1/20194/3/2019 12:32:48 PMPPEND
Todd Campbell construction is aware that the pile needs to be removed, but ground has been very wet and soft and not good for work to occur.

2 week follow up scheduled.
ESC18-00079 General Inspection4/1/20194/1/20194/2/2019 1:51:11 PM PASS
Needs landscaping on terrace areas above walls. BLD permit still active. No sediment runoff issues.
ESC18-01119 Site Preparation3/29/20194/1/20194/2/2019 10:09:26 AMAPASS
Review site to remove SWO. Permission granted for drywall work to occur this weekend.

SWO removed. Site cleaned up and fencing re-installed. Warning to not trespass into the open space easement.
ESC18-00983 General Inspection4/1/20194/1/20194/1/2019 12:40:32 PMPFAIL
Corrections needed:
- sweep shoulder and entrance at Holcomb
- repair barrow ditch erosion occuring at top portion of site (west boundary) that directs water down the corner of the cut slope.
- maintain any loose or displaced wattles
- remove or stabilize large stockpiles.
- make sure that berm at top of slope is intact and level across the entirere length
- smooth out tire ruts that channels and concentrates sheet flow
- fix erosion at the northeast corner of site above the bend in Holcomb Road.

RP steve states that erosion repairs and wattle maintenance are to occur this week. Will schedule a follow up site walk. Verbal correction requests to Steve.
ESC17-01693 BMP Violation4/1/20194/1/20194/1/2019 11:52:26 AMPFAIL
Multiple violations:
- trackout, dirt, and debris on sidewalk, gutter, and bike lane.
- no regular housekeeping
- no stabilized entrance

Correction Notice posted. Multiple failed inspections at this site, next Fail will result in a SWO.

VM to owner-RP left.

Follow Up Wednesday AM.
ESC17-01346 General Inspection4/1/20194/1/20194/1/2019 11:17:17 AM PASS
No trackout. Clean site. Storm drains have sediment protection.