PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Thursday, April 30, 2020
.
Number of inspections:
11
Percentage of inspections complete:
91 %
Percentage of inspections not complete:
9 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC16-00935
General Inspection
4/27/2020
4/27/2020
ESC20-00480
General Inspection
4/30/2020
4/30/2020
5/8/2020 2:21:34 PM
P
CANC
ESC19-00114
General Inspection
4/30/2020
4/30/2020
5/8/2020 2:21:11 PM
CANC
rescheduled for site final
ESC19-00932
General Inspection
4/30/2020
4/30/2020
5/8/2020 2:20:42 PM
CANC
ESC18-01227
Complaint Inspection
4/30/2020
4/30/2020
5/4/2020 2:48:36 PM
P
DONE
Notified RP to continue picking up any windblown trash in Magnolia Park daily and checking that all loose wrappings and trash within site are contained.
ESC18-01168
BMP Violation
4/29/2020
4/30/2020
5/1/2020 3:12:17 PM
P
PASS
Corrections completed as requested. Follow up walk through inspection of full perimeter scheduled
ESC19-00371
General Inspection
4/30/2020
4/30/2020
4/30/2020 6:35:25 PM
P
FAIL
post rain inspection
Thunderstorm conditions with > 0.3" in one hour passed over site.
No hillside or slope erosion within site. Water from new subdivsion areas is contained on site by grading/channeling on Vortex to the detention ponds behind dam (no outlet).
Stormwater from existing roads and stormwater system is flowing into the pond at Ridgepoint and Vortex which has been under re-construction and expansion. Stormwater is picking up turbidity in this pond since it is not yet complete and previous attempts to line the bottom of the pond to keep accumulated sediment down have not worked.
Outlet pipe from pond is supposed to be connect only to the bypass pipe, instead water is surfacing out of manhole , flowing over disturbed area into the old section of creek and into the new stormwater pipe which does not have the proper outlet protection and additional erosion is occuring at the outlet. Bypass pipe must not be connected correctly or is plugged, only small amount of the water is going through the bypass.
Correction requests:
- connect pipes to new stormwater system so water leaving the pond does not go to surface
- install outlet protection (rip rap, lining) to prevent erosion at the discharge point of all pipe outlets at bottom of site.
- work on way to prevent stormwater from existing system from getting dirty in the unfinished pond
- write corrective action report for SWPPP
- have turbidimeter onsite until completion to take readings of every discharge
Discharge was muddy at bottom of site. Muddy water was observed flowing into Walling Creek which is connected to the Boise River.
- Consider increasing retention time in Ridgepoint/Vortex pond of having a valve to stop flows once rain has stopped to let water settle/pump out down to resevoir.
Investigation, corrective actiions, and enforcement is pending.
RP was onsite working to make corrections and order labor and supplies for tommorrow.
Follow up scheduled.
ESC19-00833
Aging Inspection
4/30/2020
4/30/2020
4/30/2020 8:26:58 AM
CANC
ESC19-00833
DOC - Permit Finaled
4/30/2020
4/30/2020
4/30/2020 8:22:29 AM
P
PASS
ESC19-00770
General Inspection
4/30/2020
4/30/2020
4/30/2020 8:21:21 AM
PASS
WIP on exterior finish. Driveway is already paved and front slope below is vegetated. No violations observed
ESC17-00791
General Inspection
4/30/2020
4/30/2020
4/30/2020 8:20:21 AM
CANC