ESC16-00948
| General Inspection | 4/4/2017 | 4/4/2017 | 4/7/2017 3:05:59 PM | P | PART |
|
|
No trackout. Neff Street will need sweeping next week. Currently demolishing small house under seperate permit. East end of Neff is soon to be paid. Will check in next week.
|
ESC17-00114
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/5/2017 3:33:08 PM | P | PASS |
|
|
Phone #: ###-####
Approved for excavation. Subdivision BMPs installed.
|
ESC15-00957
| General Inspection | 4/4/2017 | 4/4/2017 | 4/5/2017 3:30:23 PM | | FAIL |
|
|
Need to clean up and remove existing concrete washout and dumped materials. Correction request already issued to Evan Construction & Tahoe.
|
ESC16-00397
| Aging Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 3:58:51 PM | | CANC |
|
|
|
ESC17-00241
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 3:58:21 PM | P | PASS |
|
|
Project has already started. Call me if you would like me to meet you there. Phone #: ###-#### Inspection requested via web by Eldon Oyadomari
|
ESC16-01720
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 3:57:29 PM | P | PART |
|
|
On site contact for CM - Brandon ###-####
Construction fencing installed around work area, MS4 inlet protection bags installed.
Correction: - need to adjust inlet protection to account for water entering curb cut - post ESC permit sign at site entrance
|
ESC15-00853
| General Inspection | 4/3/2017 | 4/4/2017 | 4/4/2017 2:44:51 PM | A | FAIL |
|
|
Need to conduct maintenance on sediment filter bags on Hill Terrace. Sweep up North Hill sub entrance aprons. RP stated excess sediment on Hill Terrace due to recently replaced gas line. Crews in process of sweeping and removing loose dirt.
Developer stated excess soil stockpiles from site are to be hauled off next week. Will check back later in weekn
|
ESC15-00378
| Site Final | 4/4/2017 | 4/4/2017 | 4/4/2017 12:04:28 PM | P | PASS |
|
|
Rear hillside vegetation > 70% coverage. Home occupied and homeowner doing gardening/landscaping. Front driveway vegetation still establishing, area is confined with retaining wall. No temp BMPs in ROW. No further ESC inspections, permit finaled.
|
ESC15-00378
| General Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 11:57:08 AM | | PASS |
|
|
|
ESC17-00151
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 11:37:22 AM | P | PASS |
|
|
I need to get the Erosion inspection. ESC number is 17-00151 Phone #: ###-#### Inspection requested via web by Trevor Mills
Permit sign posted. Roadside vegetation preserved. MS4 inlet south of site on 36th has inlet protection installed.
Approved for construction.
|
ESC17-00151
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 11:21:29 AM | P | CANC |
|
|
|
BLD17-00375
| BLD-Other | 4/3/2017 | 4/4/2017 | 4/4/2017 11:21:19 AM | A | CANC |
|
|
I need to get the Erosion inspection. ESC number is 17-00151 Phone #: ###-#### Inspection requested via web by Trevor Mills
|
ESC17-00029
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 11:20:34 AM | P | PASS |
|
|
Dean Phone #: ###-####
Permit signs posted at site. Concrete washout bin provided onsite. RP-GC on site for inspection. Storm drain inlet to the east on Poplar will have filter mat installed. Driveways will be installed on alley, no new curb cutting
Will check back for inlet protection next inspection
|
ESC17-00026
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 11:19:09 AM | P | PASS |
|
|
Permit signs posted at site. Concrete washout bin provided onsite. RP-GC on site for inspection. Storm drain inlet to the east on Poplar will have filter mat installed. Driveways will be installed on alley, no new curb cutting
|
ESC17-00152
| Site Preparation | 4/4/2017 | 4/4/2017 | 4/4/2017 11:17:32 AM | P | PASS |
|
|
Dean Phone #: ###-####
Permit signs posted at site. Concrete washout bin provided onsite. RP-GC on site for inspection. Storm drain inlet to the east on Poplar will have filter mat installed. Driveways will be installed on alley, no new curb cutting
|
ESC16-01475
| Complaint Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 10:42:24 AM | P | FAIL |
|
|
No washout containment provided for foundation crew. Spilled slurry and aggregate in unpaved driveway.
RP to clean up today and provide lined designated washout for remaining cement work.
|
ESC16-00233
| General Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 8:08:51 AM | | CANC |
|
|
|
ESC16-00430
| General Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 8:08:42 AM | | PASS |
|
|
No trackout to Ustick. Building structure is complete, site work in progress. Will need to make sure they remove temp DI bag upon stabilization. NO corrections at this time.
|
ESC16-00406
| General Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 8:05:28 AM | | PEND |
|
|
Slopes are in good condition with ECB and seeded grasses starting to grow. RP to provide seed mix details and ECB specs to analyze potential for some alternative revegetation tactics.
Correction request: - conduct maintenance on rock construcction entrance on HV road - change out DI bags on HV road.
Will check back this Thursday
Corr
|
ESC15-01391
| General Inspection | 4/4/2017 | 4/4/2017 | 4/4/2017 7:53:12 AM | | CANC |
|
|
|