Inspections for the day of: Monday, April 9, 2018.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00774 General Inspection4/6/20184/9/20184/11/2018 4:08:11 PMAPEND
No corrections issued. Vegetation for banks is establishing well on coir mat, but not the straw netted mat. Some minor rilling will need to be addressed.

Working on request to Harris Ranch facilities crew to pick up trash in original channel of Warm Springs Creek.
ESC17-00249 Tracking Control4/6/20184/9/20184/10/2018 4:35:41 PMAPASS
Trackout previously observed was cleaned up. WIP on installing curb and gutter.
ESC16-01432 General Inspection4/9/20184/9/20184/9/2018 4:24:47 PM PASS
HOme complete and landscaped. Temporary BMPs removed. No ESC corrections. Adajacent lot has been purchased.
ESC16-01432 DOC - Permit Finaled4/9/20184/9/20184/9/2018 4:23:55 PMPPASS
ESC17-01287 Site Preparation4/9/20184/9/20184/9/2018 3:14:11 PMPPASS
Tim Phone #: ###-####

Initial BMPs installed (silt fence) at bottom of site. Will use existing shared driveway to access lot.
ESC17-00842 General Inspection4/9/20184/9/20184/9/2018 1:43:15 PMPFAIL
Perimeter wattles insufficient to hold sediment on site. Muddy runoff on culdesac, water deposited sediment/mud in neighbors front yard and driveway.

Lower silt fence on west side of street directing water to neighbors backyard.

Corrections:
- J hook silt fence on west side, install slope interupting wattles up hill
- Insstall silt fence perimter at top of culdesac
- install earth berm/diversion channel at top of common driveway at top.
- repair erosion caused by flushing
- install wattles on slope above retaining wall
- site is to be hydroseeded w/ tacifier this week

- clean up loose sediment on road. Address neighbor concerns about dirt on driveway and in landscaping.]

Waterline crews flushing muddy water due to the sediment on street flowed down street during inspection. Flush water is allowed but requested to not direct water over dirty areas. Too much pressure to do on vegetated slopes. Request to remove storm drain sediment bag to prevent flow of water down Lancaster.
ESC16-01095 Aging Inspection4/9/20184/9/20184/9/2018 8:47:58 AM PASS
No activity on BLD; no ESC issues at site. No further inspections, ESC permit finaled.
ESC16-01095 DOC - Permit Finaled4/9/20184/9/20184/9/2018 8:47:33 AMPPASS
ESC39-00001 Aging Inspection4/9/20184/9/20184/9/2018 8:46:02 AM CANC