Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC15-00853 General Inspection5/17/20185/17/20185/21/2018 3:05:11 PM PART
Corrections needed:

- backfill should not be stored on the road with out perimeter controls
- need to clearly label concrete washout and secure lining. Leakage is visible.

- empty out DI bag on the east side of entrance.

Verbal correction to RP-developer Ron
ESC13-00524 General Inspection5/17/20185/17/20185/21/2018 2:50:54 PMPPASS
post rainfall
ESC17-00190 General Inspection5/17/20185/17/20185/21/2018 2:49:06 PMPPEND
post rainfall inspection

No recent activity. NO sediment accumulated in road; no new slope erosion observed.

No corretive action has been taken on gully that has developed on the slope between the upper section and end of culdesdac. No discharge, but could worsen and increase erosion on this slope
Need to install slope stabilization or slope interupting wattles next to rip-rapped channel and drainage structure on the 3rd lot on the right hand side. Rilling and evidence of sediment loss into the drainage structure.
ESC15-01288 General Inspection5/17/20185/17/20185/18/2018 4:47:38 PM CANC
rescheduled
ESC18-00128 BMP Violation5/16/20185/17/20185/18/2018 3:56:50 PMAPEND
check for wattles installed

Wattles now on site. To be installed over weekend.
ESC18-00020 Conference5/17/20185/17/20185/18/2018 12:36:52 PMPDONE
3 PM w/ HHS and Syman

Site compliance conference with project managers.

Corrections:
- check that all DI bags and storm drain grates are properly installed and allow runoff to enter the filter bag

- fix rip rap channel to Council Springs Creek. Will fix channel lining and stabilize/armor sides to prevent further erosion and widening of channel.

- fix eroded area between Barber Drive and rip rap channel on way up to Hootowl. Will prevent runon from high flows in gutter, track area and stabilze.
- HHS will schedule SFH site preparation inspections once per week at a minimum with ESC division.

- Install sedimentation basin and improved construction entrance on the upper excavation and unfinished area at top of Barber Drive.

- properly trench in and overlap ends at all wattle installation.

- streets to be swept at minimum of once per week as well as regular trash pick up.

HHS and Syman have started on corrections. Will follow up on channel repairs and DI bag installations on Thursday 5/24
ESC18-00494 Complaint Inspection5/17/20185/17/20185/18/2018 8:53:18 AMPFAIL
Work still occuring at site, basement excavation. BLD permit already finaled.

Excavated dirt was hauled to a non-permitted site 4612 Gage Street. A UST with heating oil was uncovered and some reportedly spilled. 300 gallons extracted from tank by Gem State Recovery

Contaminated dirt at Gage Street is currently being tested and is scheduled to be hauled away Monday. Stockpiles have been covered, and located to center of lot.


ESC17-00682 General Inspection5/17/20185/17/20185/18/2018 8:33:00 AM CANC
ESC16-01725 General Inspection5/16/20185/17/20185/18/2018 8:20:00 AMACANC
ESC17-00954 General Inspection5/17/20185/17/20185/18/2018 8:17:17 AMPCANC
ESC17-00806 General Inspection5/17/20185/17/20185/18/2018 8:15:02 AM PASS
BLD finaled for this home. Home landscaped/stabilized. ESC inspections of Harris North continued under ESC18-00020
MIS18-00186 ESC-Conference5/17/20185/17/20185/17/2018 2:52:40 PMAFAIL
Complaint dumped large amount of dirt on this vacant lot, it is next to a lateral, and the dirt smells of checmicals. House was demolished on this lot under BLD17-04552.

Dirt excavated from nearby 4205 Edgemont dumped by 3D construction services. UST of heating oil was uncovered. 300 gallon recovered by Gem State Oil.

Stockpiles smell like gas/oil, some areas more so than others. DEQ Waste & Remediation Manager directed contractor to remove the dirt and show verification of its final location. Builder wants to test the dirt. Will cover until results.

Correction notice to remove all dirt stockpiles away from the irrigation lateral today.

No active ESC permit obtained to dump dirt or grade dirt on this lot. ESC permit required. Double fee for working without permit

Case still pending...
ESC17-00687 General Inspection5/17/20185/17/20185/17/2018 8:04:56 AM CANC
ESC17-00897 Aging Inspection5/17/20185/17/20185/17/2018 8:00:29 AM CANC
ESC16-01040 Aging Inspection5/17/20185/17/20185/17/2018 7:54:06 AM CANC
ESC16-01665 Aging Inspection5/17/20185/17/20185/17/2018 7:53:55 AM CANC
ESC16-01653 Aging Inspection5/17/20185/17/20185/17/2018 7:53:44 AM CANC