PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Thursday, May 17, 2018
.
Number of inspections:
17
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Andy J. Long
Title
EROSION INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC15-00853
General Inspection
5/17/2018
5/17/2018
5/21/2018 3:05:11 PM
PART
Corrections needed:
- backfill should not be stored on the road with out perimeter controls
- need to clearly label concrete washout and secure lining. Leakage is visible.
- empty out DI bag on the east side of entrance.
Verbal correction to RP-developer Ron
ESC13-00524
General Inspection
5/17/2018
5/17/2018
5/21/2018 2:50:54 PM
P
PASS
post rainfall
ESC17-00190
General Inspection
5/17/2018
5/17/2018
5/21/2018 2:49:06 PM
P
PEND
post rainfall inspection
No recent activity. NO sediment accumulated in road; no new slope erosion observed.
No corretive action has been taken on gully that has developed on the slope between the upper section and end of culdesdac. No discharge, but could worsen and increase erosion on this slope
Need to install slope stabilization or slope interupting wattles next to rip-rapped channel and drainage structure on the 3rd lot on the right hand side. Rilling and evidence of sediment loss into the drainage structure.
ESC15-01288
General Inspection
5/17/2018
5/17/2018
5/18/2018 4:47:38 PM
CANC
rescheduled
ESC18-00128
BMP Violation
5/16/2018
5/17/2018
5/18/2018 3:56:50 PM
A
PEND
check for wattles installed
Wattles now on site. To be installed over weekend.
ESC18-00020
Conference
5/17/2018
5/17/2018
5/18/2018 12:36:52 PM
P
DONE
3 PM w/ HHS and Syman
Site compliance conference with project managers.
Corrections:
- check that all DI bags and storm drain grates are properly installed and allow runoff to enter the filter bag
- fix rip rap channel to Council Springs Creek. Will fix channel lining and stabilize/armor sides to prevent further erosion and widening of channel.
- fix eroded area between Barber Drive and rip rap channel on way up to Hootowl. Will prevent runon from high flows in gutter, track area and stabilze.
- HHS will schedule SFH site preparation inspections once per week at a minimum with ESC division.
- Install sedimentation basin and improved construction entrance on the upper excavation and unfinished area at top of Barber Drive.
- properly trench in and overlap ends at all wattle installation.
- streets to be swept at minimum of once per week as well as regular trash pick up.
HHS and Syman have started on corrections. Will follow up on channel repairs and DI bag installations on Thursday 5/24
ESC18-00494
Complaint Inspection
5/17/2018
5/17/2018
5/18/2018 8:53:18 AM
P
FAIL
Work still occuring at site, basement excavation. BLD permit already finaled.
Excavated dirt was hauled to a non-permitted site 4612 Gage Street. A UST with heating oil was uncovered and some reportedly spilled. 300 gallons extracted from tank by Gem State Recovery
Contaminated dirt at Gage Street is currently being tested and is scheduled to be hauled away Monday. Stockpiles have been covered, and located to center of lot.
ESC17-00682
General Inspection
5/17/2018
5/17/2018
5/18/2018 8:33:00 AM
CANC
ESC16-01725
General Inspection
5/16/2018
5/17/2018
5/18/2018 8:20:00 AM
A
CANC
ESC17-00954
General Inspection
5/17/2018
5/17/2018
5/18/2018 8:17:17 AM
P
CANC
ESC17-00806
General Inspection
5/17/2018
5/17/2018
5/18/2018 8:15:02 AM
PASS
BLD finaled for this home. Home landscaped/stabilized. ESC inspections of Harris North continued under ESC18-00020
MIS18-00186
ESC-Conference
5/17/2018
5/17/2018
5/17/2018 2:52:40 PM
A
FAIL
Complaint dumped large amount of dirt on this vacant lot, it is next to a lateral, and the dirt smells of checmicals. House was demolished on this lot under BLD17-04552.
Dirt excavated from nearby 4205 Edgemont dumped by 3D construction services. UST of heating oil was uncovered. 300 gallon recovered by Gem State Oil.
Stockpiles smell like gas/oil, some areas more so than others. DEQ Waste & Remediation Manager directed contractor to remove the dirt and show verification of its final location. Builder wants to test the dirt. Will cover until results.
Correction notice to remove all dirt stockpiles away from the irrigation lateral today.
No active ESC permit obtained to dump dirt or grade dirt on this lot. ESC permit required. Double fee for working without permit
Case still pending...
ESC17-00687
General Inspection
5/17/2018
5/17/2018
5/17/2018 8:04:56 AM
CANC
ESC17-00897
Aging Inspection
5/17/2018
5/17/2018
5/17/2018 8:00:29 AM
CANC
ESC16-01040
Aging Inspection
5/17/2018
5/17/2018
5/17/2018 7:54:06 AM
CANC
ESC16-01665
Aging Inspection
5/17/2018
5/17/2018
5/17/2018 7:53:55 AM
CANC
ESC16-01653
Aging Inspection
5/17/2018
5/17/2018
5/17/2018 7:53:44 AM
CANC