Inspections for the day of: Thursday, June 20, 2019.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01767 General Inspection6/14/20196/20/20196/25/2019 12:34:25 PMAPASS
ESC18-00928 General Inspection6/14/20196/20/20196/25/2019 12:34:16 PMAPASS
ESC18-00737 Site Final6/13/20196/20/20196/25/2019 12:33:59 PMPNR
ESC18-00738 Site Final6/14/20196/20/20196/25/2019 11:20:02 AMANR
Need final perimter and surrounding slope trash pick and removal of temporary BMPs installed (silt fence)
ESC18-00992 Aging Inspection6/20/20196/20/20196/24/2019 3:16:40 PM CANC
ESC18-01121 General Inspection6/20/20196/20/20196/24/2019 3:16:21 PM PASS
ESC18-00956 General Inspection6/20/20196/20/20196/21/2019 1:58:44 PM CANC
ESC18-00363 General Inspection6/20/20196/20/20196/21/2019 1:58:38 PM CANC
ESC18-00977 General Inspection6/20/20196/20/20196/20/2019 2:55:23 PM CANC
ESC18-01657 BMP Violation6/20/20196/20/20196/20/2019 2:55:13 PMPFAIL
Dirt sidewalk and apron in front of site on Sherman Street. Previous request to sweep was not followed.

Correction request to sweep up the apron. Follow up scheduled.
ESC18-01006 Aging Inspection6/20/20196/20/20196/20/2019 2:50:22 PM PASS
No exterior disturbance, no futher ESC inspections required.
ESC18-01006 DOC - Permit Finaled6/20/20196/20/20196/20/2019 2:49:20 PMPPASS
ESC18-01162 BMP Violation6/20/20196/20/20196/20/2019 2:47:01 PMPFAIL
Dumped washout on adjacent one lot (from pool contractor per GC/RP) perimeter wattles are no longer properly installed. Gravel gutter check bag has a lot of accumulated sand and some stucco/concrete slurry.

Corrections:
- clean up gutter and sidewalk
- clean up dumped washout
- re-install sections of watlle that are dislodged.

Verbal correction request issued to GC-RP Justin. Compliance follow up scheduled for Monday 6/24
ESC18-00999 Aging Inspection6/20/20196/20/20196/20/2019 2:41:15 PM CANC
ESC18-00311 General Inspection6/20/20196/20/20196/20/2019 2:40:45 PM CANC
ESC18-00847 General Inspection6/20/20196/20/20196/20/2019 2:40:20 PM CANC
ESC18-00882 General Inspection6/20/20196/20/20196/20/2019 2:38:48 PM CANC
ESC18-01003 Aging Inspection6/20/20196/20/20196/20/2019 2:38:00 PM CANC
pool installed, BLD open. No ESC issues
ESC18-01003 DOC - Permit Finaled6/20/20196/20/20196/20/2019 2:37:11 PMPPASS
ESC18-01124 General Inspection6/20/20196/20/20196/20/2019 2:35:57 PM CANC
ESC17-00985 General Inspection6/20/20196/20/20196/20/2019 2:35:50 PM CANC
ESC18-01000 Aging Inspection6/20/20196/20/20196/20/2019 2:35:32 PM CANC
ESC18-01000 DOC - Permit Finaled6/20/20196/20/20196/20/2019 2:35:19 PMPPASS
ESC18-01237 BMP Violation6/20/20196/20/20196/20/2019 2:33:50 PMPFAIL
Overflowing trash containment. Uncontained concrete washout dumped next to trash container, debris and slurry on sidewalk.

Correction requests:
- empty trash containment
- clean up sidewalk
- clean up piles of dumped material and remove contaminated soil
ESC19-00601 Site Preparation6/19/20196/20/20196/20/2019 11:58:00 AMAPASS
Wes Phone #: ###-####

Permit sign posted. Perimeter sediment contrlos (wattles and silt fence) installed properly. RP on site. Storm drains have sediment protection. RP states that he will have pump truck service take care of the washout instead of having onsite washout.

Excavation to begin next week. Approved for construction.