Inspections for the day of: Thursday, June 21, 2018.
Number of inspections: 27
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-01196 General Inspection6/19/20186/21/20186/25/2018 12:49:33 PMACANC
ESC16-01472 General Inspection6/19/20186/21/20186/22/2018 2:45:14 PMAPASS
follow up inspection

Wattles re-trenched where failures occured, some sections re-positioned.

Two gator guard wattles installed across road to divert flows away from neighboring properties. Upper section diverts water to a retention area (lower staging area) .

No new corrections.

ESC17-00824 General Inspection6/21/20186/21/20186/22/2018 11:56:15 AM PASS
No activity. Slopes on lot are mostly vegetated with grass and weeds.Silt fence installed at bottom of lot is trenched in with no breaks. No sediment runoff or hillside erosion on lot.
ESC16-01694 General Inspection6/7/20186/21/20186/22/2018 10:16:09 AMPCANC
ESC16-01027 General Inspection6/7/20186/21/20186/22/2018 10:13:52 AMACANC
ESC17-00513 General Inspection6/21/20186/21/20186/21/2018 4:05:33 PM FAIL
Trackout to Fort Street. Dump trucks hauling off dirt do have a tracking pad to cross over.

Observed water truck rinsing street without a sweeper, potential for turbid non-stormwater discharge. MS4 inlets have sediment filter bags installed.

Correction request:
- sweep apron, minimize rinsing to be acompanied by sweeping to prevent runoff.

Project manager Jan with Beniton notified of corrections. Stated stockpile hauloff will be completed tomorrow and sweeping and clean will increase instead of installing new rock entrance for this operation.

Follow up tomorrow PM
ESC18-00734 Site Preparation6/21/20186/21/20186/21/2018 3:16:00 PMPPASS
check out site for what BMPs it may need.

Large flat lot with some existing vegetation and gravel driveway. RP will post ESC permit sign. Work to begin next week.

No additional BMPs requested at this time, just housekeeping and dust control.. Approved for construction.
ESC17-00693 General Inspection6/21/20186/21/20186/21/2018 3:00:34 PM PASS
ESC17-00190 General Inspection6/21/20186/21/20186/21/2018 2:53:45 PM FAIL
Hillside erosion on many slopes and some undercutting of sidewalk is occuring in various locations. Some hillside wattles were installed but have been undercut. A storm drain drop inlet sump has filled up with eroded dirt and is covering outlet pipe.

Corrections:
- work on plan to install more hillside ESC controls until timing for re-seeding is better later this year.
- check that BMPs are installed per ESC site map. Update as needed
- regrade driveways where runoff is flowing off sides over steep sparsely vegetated slopes.
- have storm drain that is clogged cleaned out.

RP to work on corrective action plan and inspect. On site conference scheduled for 9 AM 6/28, next Thursday. Verbal correction request issued to RP Scott.
ESC17-00971 Conference6/21/20186/21/20186/21/2018 10:34:41 AMADONE
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC16-01685 Aging Inspection6/21/20186/21/20186/21/2018 10:24:48 AM CANC
ESC16-01685 DOC - Permit Finaled6/21/20186/21/20186/21/2018 10:24:44 AMPPASS
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC16-01686 Aging Inspection6/21/20186/21/20186/21/2018 10:24:28 AM CANC
ESC16-01686 DOC - Permit Finaled6/21/20186/21/20186/21/2018 10:24:24 AMPPASS
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC16-01668 Aging Inspection6/21/20186/21/20186/21/2018 10:24:12 AM CANC
ESC16-01668 DOC - Permit Finaled6/21/20186/21/20186/21/2018 10:24:08 AMPPASS
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC18-00623 Site Final6/21/20186/21/20186/21/2018 10:17:39 AMPPASS
Demolition complete. See ESC18-00734 for new SFH by Syringa Construction
ESC16-01667 Aging Inspection6/21/20186/21/20186/21/2018 10:14:01 AM CANC
ESC16-01667 DOC - Permit Finaled6/21/20186/21/20186/21/2018 10:13:57 AMPPASS
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC16-01661 Aging Inspection6/21/20186/21/20186/21/2018 10:13:45 AM CANC
ESC16-01661 DOC - Permit Finaled6/21/20186/21/20186/21/2018 10:13:36 AMPPASS
see ESC16-01027 for remaining ESC inspections and corrections for the Cottages at Whitecloud by Perryman Construction
ESC17-00836 Site Final6/21/20186/21/20186/21/2018 9:55:32 AMANR
Correction request:

- install sediment control wattle on the lot downhill from home on Sherman that was used for site access & staging and accidental water line break.

Discussed with RP Mike. Follow up scheduled for next week.
ESC16-00989 General Inspection6/21/20186/21/20186/21/2018 7:59:15 AM CANC
ESC17-00422 General Inspection6/21/20186/21/20186/21/2018 7:58:38 AMPCANC
ESC17-01144 Site Final6/21/20186/21/20186/21/2018 7:58:29 AMPCANC
monument sign installed?
ESC17-00455 General Inspection6/21/20186/21/20186/21/2018 7:58:15 AM CANC
ESC15-01420 General Inspection6/21/20186/21/20186/21/2018 7:40:02 AM CANC