Inspections for the day of: Thursday, July 13, 2017.
Number of inspections: 24
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC16-01429 Site Final7/7/20177/13/20177/13/2017 2:24:08 PMPPASS
Project complete, stabilized/re-vegetated. ESC conditions satisfied.
ESC16-01429 DOC - Permit Finaled7/13/20177/13/20177/13/2017 2:23:42 PMPPASS
ESC16-00938 General Inspection7/13/20177/13/20177/13/2017 1:20:11 PMPPASS
revegetation and stabilization near complete. Temporary wattle still installed.
ESC16-01259 DOC - Permit Finaled7/13/20177/13/20177/13/2017 12:55:42 PMPPASS
ESC16-00853 General Inspection7/13/20177/13/20177/13/2017 12:38:24 PM PART
No trackout, loose trash or discharges.

Correction request to relocate stucco crew staging area off adjacent lot that has been source of track out and contention.
ESC17-00478 General Inspection7/13/20177/13/20177/13/2017 12:16:21 PMPFAIL
Trash container is over full. Wind blown trash and debris blown around multiple sites in RH#7. Request issued to empty containers and have crew do a litter pick up in the common areas and site perimeter.
ESC15-01288 General Inspection7/13/20177/13/20177/13/2017 12:13:21 PM PART
WIP on multiple SFHs in RH#7. No significant trackout, no discharges leaving site. No fugitive dust observed.

Corrections:
- concrete washout is ready for service and over 75% full
- trash bins at site are over full, wind blown trash and wrappings in drainage area and site perimeters should be picked up. Issued request to Brighton Homes RP in addition to subdivision development.
- remove expired wattle netting strewn along side Warm Springs in front of project.

Will check in on conditions next week
ESC17-00674 Site Preparation7/13/20177/13/20177/13/2017 12:03:43 PMPPASS
Clint Phone #: ###-####


Subdivision BMPs installed. Current projects in compliance. Approved for construction
ESC17-00675 Site Preparation7/13/20177/13/20177/13/2017 12:03:20 PMPPASS
Clint Phone #: ###-####

Subdivision BMPs installed. Current projects in compliance. Approved for construction
ESC16-01561 General Inspection7/13/20177/13/20177/13/2017 11:50:45 AMPPASS
No activity. New streets and stormwater infrastructure installed. DI's fitted with sediment bags. Wattles and vegetation preserved next to Walling Creek pathway
ESC16-01169 Aging Inspection7/13/20177/13/20177/13/2017 11:37:22 AM PASS
Harris Crossing townhome complete, landscaped. Temp BMPs in sub to remain till all construction activities stop. No corrections.
ESC16-01169 DOC - Permit Finaled7/13/20177/13/20177/13/2017 11:37:14 AMPPASS
ESC16-01170 Aging Inspection7/13/20177/13/20177/13/2017 11:36:58 AM PASS
Harris Crossing townhome complete, landscaped. Temp BMPs in sub to remain till all construction activities stop. No corrections.
ESC16-01170 DOC - Permit Finaled7/13/20177/13/20177/13/2017 11:36:50 AMPPASS
ESC16-01171 Aging Inspection7/13/20177/13/20177/13/2017 11:36:41 AM PASS
Harris Crossing townhome complete, landscaped. Temp BMPs in sub to remain till all construction activities stop. No corrections.
ESC16-01171 DOC - Permit Finaled7/13/20177/13/20177/13/2017 11:36:35 AMPPASS
ESC16-01172 Aging Inspection7/13/20177/13/20177/13/2017 11:36:19 AM PASS
Harris Crossing townhome complete, landscaped. Temp BMPs in sub to remain till all construction activities stop. No corrections.
ESC16-01172 DOC - Permit Finaled7/13/20177/13/20177/13/2017 11:34:53 AMPPASS
ESC16-00489 General Inspection7/13/20177/13/20177/13/2017 11:26:36 AM PASS
ESC14-01083 General Inspection7/13/20177/13/20177/13/2017 11:08:58 AM PASS
WIP on west end of subdivision. STormdrains have sediment bags installed. Okay to remove DI bags east of Mare Street. Concrete washout facility provided. Trash and materials are contained. Approved.
ESC17-00347 General Inspection7/13/20177/13/20177/13/2017 11:05:32 AMAPASS
Demolition and excavation of site is in progress. Water trucks on site for dust control. No trackout or fugitive dust.

Stockpiles are covered in plastic sheeting, perimeter wattle installed, and surrounding storm drains have inlet protection. Approved.
ESC16-01533 General Inspection7/13/20177/13/20177/13/2017 9:32:50 AM PASS
ESC16-01233 General Inspection7/13/20177/13/20177/13/2017 7:58:00 AM CANC
ESC16-01494 General Inspection7/12/20177/13/20177/13/2017 7:57:47 AMACANC