Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC18-01375 Tracking Control7/2/20197/2/20197/8/2019 1:34:22 PMPFAIL
complaint of dust


Loose dirt from landscaping and then blowing dust off sidewalks caused dust issue last week.

Discussed dust control requirements with onsite foreman Correction request to Biltmore have landscapers sweep up all loose material at the east end of King Street.

Follow up scheduled on main site permit, ESC18-00659.
ESC19-00658 General Inspection6/17/20197/2/20197/8/2019 1:22:08 PMPPASS
WIP. No trackout. Will need to install construction entrance or pave shared driveways before starting foundations.
ESC16-01027 Site Final6/17/20197/2/20197/8/2019 1:19:51 PMPNR
DI bags still installed on Irving at Highwood, south side of street.

Temporary BMPs must be removed to final ESC permit for the Cottages.
ESC18-00749 Aging Inspection7/2/20197/2/20197/3/2019 3:06:13 PM CANC
ESC18-00476 General Inspection7/2/20197/2/20197/3/2019 2:53:03 PM CANC
ESC18-00471 General Inspection7/2/20197/2/20197/3/2019 11:53:30 AM PASS
No trackout, fugitve dust, or discharges observed. Perimeter is clean, site fenced in. Vertical construction in progress. 25th Street currently under construction in assocation with adjacent project.
ESC19-00145 General Inspection7/2/20197/2/20197/2/2019 4:33:13 PMPPASS
No activity at time of inspection. Kootenai Road project is still in progress and very dusty.

Sewer and utilities in process of being installed. No corrections requested.
ESC18-00661 Site Final7/2/20197/2/20197/2/2019 3:34:35 PMPPASS
Project complete. No ESC requests.
ESC18-01022 General Inspection7/2/20197/2/20197/2/2019 2:50:10 PMPPASS
WIP on utility installation. No trackout. Permit info posted

Water truck on site for dust control. Storm drains on Eyrie have sediment protection.

No corrections requested.
ESC16-00406 General Inspection7/2/20197/2/20197/2/2019 1:57:36 PM PASS
No violations observed. Most corrective actions requested previously are complete. No corrections at this time.
ESC18-00498 General Inspection7/2/20197/2/20197/2/2019 1:56:48 PMPFAIL
No discharges, trackout, or fugitive dust occuring. Storm drains have sediment protection.
Streets, sidewalk, and gutters free of dirt.

Corrections needed:
- check dams or wattles need to be installed on the drainage channel above and between Lot 3 and Lot 5 block 1.
- Reinstall silt fence perimeter that is down. May be assessed for removal if upland vegetation is established.
- repair erosion and reinstall BMP between Chardie and stormwater pond. Will need additional seeding in areas that haven't vegetated.

Will follow up with developer after the holiday
ESC15-00857 General Inspection7/2/20197/2/20197/2/2019 1:44:01 PMPPASS
Storm drains have sediment protection. Some minor work has commenced to begin repair and extension of Arrow Villa. No violations observed
ESC18-00885 Site Final7/2/20197/2/20197/2/2019 1:37:03 PMPPASS
Subdivsion construction complete, SFHs in progress.

All homes being built by Hammet Homes Homes, each have their own ESC permits.

BMPs inclufer DI bags, concrete washout, trackout control, fugitive dust control.

No further ESC inspections on this permit, homes are on Forsythia and Lassen.
ESC18-00885 General Inspection7/2/20197/2/20197/2/2019 12:42:27 PMPPASS
ESC19-00311 General Inspection7/2/20197/2/20197/2/2019 12:18:13 PMPPASS
ESC18-00429 General Inspection7/2/20197/2/20197/2/2019 11:42:36 AM PASS
WIP on sports field behind the gym. Site contained.
Potential for wind blown dust , may need onsite water truck to create a crust.

Will follow up next week.
ESC18-00503 Site Final7/2/20197/2/20197/2/2019 11:30:17 AMPPASS
Site has revegetated. Home occupied. Removed first downstream DI bag. No further ESC inspections required.
ESC19-00396 General Inspection6/26/20197/2/20197/2/2019 11:14:29 AMPPEND
Stockpile still in place, foundations are now poured so backfill should occur next week. No trackout or piles of trash. Lined washout pit was used.

Will follow up with builder next week. Windy condition did show that there is some dust blowing off the pile. Builder has been notified. Site inactive.
ESC18-00737 Site Final7/2/20197/2/20197/2/2019 11:05:20 AMPPASS
Home landscaped and stabilized. BLD open, for sale sign posted.

Trash in surrounding areas has been picked up and temp. silt fence removed. Storm drain protection to remain installed. No further ESC inspecitons.
ESC19-00681 General Inspection7/2/20197/2/20197/2/2019 10:31:47 AMPPASS
Foundation poured. No major trackout. Utilized lined concrete washout. Will need to sweep up after backfill
ESC18-01531 BMP Violation7/2/20197/2/20197/2/2019 10:22:37 AMPFAIL
Concrete washout from retaining wall/driveway work dumped on ground . No concrete washout pit or container provided. Located next to culdesac sidewalk above site.

Clean up before Tuesday July 9 AM and provide washout container for remaining remain rinsing/washing needs.

Failure to comply will result in investigation fee and trade inspection parcel hold. Follow up scheudled.

No loose trash, trackout, or discharges. Silt fence frontage has been trampled.
ESC19-00398 Conference7/1/20197/2/20197/2/2019 10:17:39 AMAPASS
930-10

Site common drive has been swept requested. Stockpile no longer on pavement. Installed gravel bag check dams to direct water behind the silt fence.

Crew laying forms for lower garage foundations. More excavation remains. After driveway access installed, will install perimeter silt fence in the two downslope drainages below excavation.

RP-GC stated he will have trucks rinse into pump and pumptruck will take it back to site. Alternatively a lined pit may be used.
ESC17-00842 General Inspection7/2/20197/2/20197/2/2019 10:12:47 AM PASS
Subdivision BMPs installed and maintained. No sediment runoff. SFHs permitted seperately,. Disturbed slopes around lots have vegetated.

Permit posted.
ESC19-00371 General Inspection7/2/20197/2/20197/2/2019 8:36:43 AMPPART
Inspection conducted Thursday 6/27

- Boise ESC permit posted, SWPPP binder onsite. No significant trackout, no disharges occuring. Dry, sunny weather with light wind.
- WIP on rough grading and utilitity installation.
- Rock construction entrance installed, some trackout due to trucks exiting without driving over the track pad. Site has a sweeper unit onsite that is used at end of each day.
- No breaches in silt fence perimeter observed
- Vegetation between graded areas and SF has been preserved
- Slopes along the Trent Point entrance have been tracked, wattles installed, and some areas hydroseeded.
- Hydroseeded areas without wattles are areas with a less steep slope
- Water truck working site on haul routes to keep down dust. They request water truck to stop watering about 200 M from the construction entrance due to the trackout it was causing. No dust leaving site boundaries, no consisent plumes


Correction requests to Andy w/ Syman and Steve with CMG.
- make sure wattles installed are along contours, staked every 4-5 feet, and trenched in. Request for overlap, some wattle interrsections are tightly butted instead. Some sections on upper slope above entrance are > 8 ft apart and not aligned with contour.
- Make changes at entrance to make sure equipment exiting site uses the track pad. Suggested fencing or signages, wider rock area
ESC18-00982 General Inspection6/27/20197/2/20197/2/2019 8:22:12 AMPCANC
ESC18-00580 Aging Inspection7/2/20197/2/20197/2/2019 8:20:45 AM CANC
ESC18-00580 DOC - Permit Finaled7/2/20197/2/20197/2/2019 8:20:40 AMPPASS
ESC18-00773 Aging Inspection7/2/20197/2/20197/2/2019 8:19:59 AM CANC